Ischemic Heart Disease Clinical Trial
Official title:
Comparison Between Abluminal Biodegradable Polymer Ultrathin Sirolimus-eluting Stent and Durable-polymer Everolimus-eluting Stent (GENOSS Randomized Clinical Trial)
This study aims to evaluate the efficacy and safety of abluminal biodegradable polymer ultrathin sirolimus-eluting stent (Genoss stent) as compared with a durable-polymer everolimus-eluting stent (Xience stent) in patients with coronary artery disease.
After the introduction of the drug-eluting stents (DES), the rates of device-related failure or target lesion failure (TLF) such as restenosis has been markedly decreased, compared with the era of bare-metal stents. Nevertheless, the risk of ischemic events including very late stent thrombosis after percutaneous coronary intervention (PCI) has still remained even though the use of DES, presumably because of hypersensitivity to the polymer with persistent inflammation and delayed re-endothelialization. To overcome these issues, second-generation DES with thinner stent strut and biocompatible or biodegradable polymer were developed. Several trials demonstrated that second-generation DES provides more favorable outcome in comparison with first-generation DES. Especially, among second-generation DES, biodegradable polymer DES showed better ischemic outcomes compared to durable polymer DES in some studies. Genoss DES™ (Genoss Company Limited, Suwon, Korea) is one of newer second-generation DESs with a cobalt-chromium platform with an abluminal biodegradable polymer containing sirolimus. The Genoss DES™ is the first Korean sirolimus-eluting stent on the market and it has ultrathin strut with 70 μm strut thickness with 3 μm thin abluminal polymer coating containing Sirolimus. The polymer is designed to release approximately 70% of the total drug amount within 30 days of the implantation and is entirely absorbable within 9 months. Thus, only the metal component of the stent will remain. In the first-in-man trial comparing Genoss DES™ and Promus Element™ stent (Boston Scientific Co., Natick, MA, USA), angiographic and clinical outcomes were similar at a 9-month follow-up. However, the study was too small to conclude that the Genoss DES™ is safe and efficient for de novo coronary stenosis. To date, there has been no large-scale randomized trial evaluating the safety and efficacy of Genoss DES™. Therefore, the purpose of this trial is to determine the efficacy and safety of Genoss DES™ as compared with Xience everolimus-eluting stent (Abbott Vascular, Santa Clara, California, USA) which is widely used and has proven efficacy and safety. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Active, not recruiting |
NCT04562805 -
Infinity-Swedeheart Registry Based Randomized Clinical Trial (R-RCT)
|
N/A | |
Recruiting |
NCT05292079 -
CAPTURER PMCF Study ( rEPIC04D )
|
||
Recruiting |
NCT05292014 -
ANGIOLITE PMCF Study ( rEPIC04F )
|
||
Recruiting |
NCT05292092 -
Essential Pro PMCF Study ( rEPIC04E )
|
||
Recruiting |
NCT05292118 -
Navitian PMCF Study ( rEPIC04C )
|
||
Completed |
NCT05292105 -
NC Xperience PMCF Study( rEPIC04B)
|
||
Completed |
NCT03076801 -
Does Choral Singing Help imprOve Stress in Patients With Ischemic HeaRt Disease?
|
N/A | |
Not yet recruiting |
NCT04153383 -
Milrinone on Cardiac Performance During Off-pump Coronary Artery Bypass Surgery
|
||
Recruiting |
NCT02982434 -
The New Pharmaceutical Composition Containing Botulinum Toxin to Treat Atrial Fibrillation
|
Phase 2 | |
Recruiting |
NCT02729064 -
Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose
|
Phase 1 | |
Completed |
NCT02468401 -
Prevention of Contrast Induced Nephropathy in Patients With Advanced Renal Dysfunction Undergoing Coronary Interventions
|
N/A | |
Completed |
NCT02759406 -
Evaluation of the Palmaz Mach-5 Grooved Bare Metal Coronary Stent System Versus the Palmaz Bare Metal Coronary Stent System in Patients With Symptomatic Ischemic Heart Disease: A Safety and Performance Study
|
N/A | |
Recruiting |
NCT01681381 -
Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization
|
N/A | |
Completed |
NCT01604213 -
Effects of Vildagliptin/Metformin Combination on Markers of Atherosclerosis, Thrombosis, and Inflammation in Diabetics With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01699802 -
Influence of Inhaled Anaesthetics on Rebreathing of Carbon Dioxide When Using an Anaesthesia Gas Reflector (AnaConDa)
|
N/A | |
Completed |
NCT01334268 -
RESOLUTE China RCT
|
N/A | |
Completed |
NCT01724567 -
Copenhagen Study of Obese Patients With Ischemic Heart Disease Undergoing Low Energy Diet or Interval Training
|
N/A | |
Completed |
NCT02159235 -
Heavy Metals, Angiogenesis Factors and Osteopontin in Coronary Artery Disease (CAD)
|
N/A |