Coronary Artery Stenosis Clinical Trial
Official title:
Relationship Between Fractional Flow Reserve and Inducible Myocardial Ischemia During Adenosine Stress Testing
This is a prospective, single center study involving 150 patients with stable coronary artery disease undergoing coronary angiography for chest pain evaluation. The relationship between FFR values and inducible myocardial ischemia at the time of definite ischemia during adenosine stress testing will be investigated.
Fractional flow reserve (FFR) is commonly used to search for ischemia-producing lesions during percutaneous coronary intervention (PCI), and its assessment becomes an integral part to guide PCI when objective evidences of inducible myocardial ischemia are not available. A transient imbalance between oxygen supply and demand leads to the ischemic cascade, which are typically accompanied by regional wall motion abnormalities or electrocardiographic changes as objective evidences of inducible myocardial ischemia. FFR is a pressure-derived surrogate of coronary flow limitation defined as the ratio of distal coronary pressure to aortic pressure during maximal hyperemia. FFR has been indirectly validated against noninvasive stress tests, and large outcome trials support the benefit of FFR-guided PCI strategy. However, FFR is not a direct measurement of coronary flow, and myocardial ischemia depends on coronary flow rather than pressure. In fact, an experimental model shows that myocardial function can be maintained without evidences of myocardial ischemia despite low FFR. Furthermore, FFR did not predict improvement in symptoms or exercise performance after PCI, challenging the current threshold of FFR for discriminating ischemia-producing lesions. The clinical benefit of FFR-guided PCI is certainly related to relief of inducible myocardial ischemia. However, there is little information to examine a direct link between FFR values and documented inducible ischemia at the time of FFR measurement. Therefore, the investigators investigate the relationship between FFR values and inducible myocardial ischemia at the time of definite ischemia during adenosine stress testing. A 12-lead ECG recordings, FFR, and two-dimensional echocardiographic monitoring will be continued before, during and after adenosine infusion. When new regional wall motion abnormalities in echocardiography develop, adenosine infusion is ended and echocardiographic monitoring will be continued until left ventricular wall motion returns to normal. Apical (two-chamber, four-chamber and five chamber views) and parasternal long-axis and short-axis views will be recorded for offline analysis. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05133843 -
Complete Functional Assessment of Intermediate Coronary Artery Stenosis Before and After Transcatheter Aortic Valve Implantation (TAVI) in Patients With Severe Symptomatic Aortic Valve Stenosis
|
N/A | |
Completed |
NCT01205776 -
EXCEL Clinical Trial
|
N/A | |
Completed |
NCT01182428 -
XIENCE V: SPIRIT WOMEN Sub-study
|
Phase 4 | |
Completed |
NCT00739466 -
Biorest Liposomal Alendronate With Stenting sTudy (BLAST)
|
Phase 2 | |
Completed |
NCT01332591 -
Multivessel Disease Diagnosed at the Time of PPCI for STEMI: Complete Revascularization Versus Conservative Strategy.
|
N/A | |
Completed |
NCT01310309 -
EXecutive Registry: Evaluating XIENCE V® in a Multi Vessel Disease
|
Phase 4 | |
Completed |
NCT00531011 -
EXecutive RCT: Evaluating XIENCE V® in a Multi Vessel Disease
|
Phase 4 | |
Not yet recruiting |
NCT06052670 -
Functional Diagnostic Accuracy of Ultrasonic Flow Ratio in Assessment of Coronary Artery Lesions
|
||
Completed |
NCT05509296 -
Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease
|
N/A | |
Not yet recruiting |
NCT05393882 -
Impact of Cholesterol Level on Long-term Coronary Bypass Graft Patency
|
||
Recruiting |
NCT06397820 -
Relation Between AI-QCA and Cardiac PET
|
||
Active, not recruiting |
NCT01960504 -
First in Man Study of the DREAMS 2nd Generation Drug Eluting Absorbable Metal Scaffold (BIOSOLVE-II)
|
N/A | |
Completed |
NCT01721096 -
XIENCE PRIME Japan Post-Marketing Surveillance (PMS)
|
||
Active, not recruiting |
NCT01342822 -
Trial to Assess the Everolimus-Eluting Coronary Stent System (PROMUS Element) for Coronary Revascularization
|
Phase 4 | |
Completed |
NCT01205789 -
EXCEL Clinical Trial (Universal Registry)
|
N/A | |
Recruiting |
NCT05532605 -
Effects of Mindfulness Based Therapy on Illness and Depression in Cardiac Rehab Phase-i
|
N/A | |
Completed |
NCT02066623 -
Observational Study to Evaluate Short and Long-term Safety of the ABSORB Scaffold
|
||
Not yet recruiting |
NCT02946320 -
Optimal Predilatation Technique for BVS Implantation
|
Phase 3 | |
Completed |
NCT01136876 -
Kidney Damage in Patients With Moderate Fall in eGFR
|
Phase 4 | |
Terminated |
NCT01136915 -
Kidney Damage In Patients With Severe Fall In eGFR
|
Phase 4 |