Clinical Trials Logo

Clinical Trial Summary

Coronary artery computed tomographic angiography (CTA) is a widely used, highly accurate technique for the detection of coronary artery disease (CAD), with sensitivity and negative predictive values of over 90% (1-4). Patients with normal CTA findings have an excellent prognosis and do not require further testing for CAD (5). However, like invasive coronary angiography (QCA), CTA is an anatomic test and, unless lesions are very severe (>90% stenosis), cannot reliably predict the impairment of flow (functional significance) of intermediate grade stenoses. For this reason, in approximately 15-25% of patients, additional functional testing may be required after CTA, usually in the form of stress testing (6-8). Stress testing is commonly done by exercise or pharmacologic stress with electrocardiographic monitoring and often, imaging of myocardial perfusion by nuclear scintigraphy (MPI) or detection of abnormal contraction by echocardiography. This requires a separate procedure, entailing time, expense and limited risk. Furthermore, in patients with previously known CAD, CTA alone is not an adequate test, because in most cases there are multiple lesions that are possible sources of ischemia. Over the last 10 years, these investigators and others around the world have developed a method of imaging myocardial perfusion by CT (CTP). This test is an adjunct to the usual Cardiac Computed Tomography Angiography (CCTA) procedure and can be done immediately thereafter, using conventional pharmacologic stress agents. It has demonstrated accuracy in many single center trials, and in this large multicenter study, the CORE320 trial (9,10) which showed a high accuracy in predicting the combined results of QCA plus MPI testing and a second multicenter trial established non-inferiority of myocardial CTP compared with nuclear stress testing (11,12). Additionally, this investigator group has published a direct comparison of diagnostic performance of myocardial CTP imaging and SPECT myocardial perfusion imaging and demonstrated superior diagnostic performance of CTP imaging compared with SPECT for the diagnosis of significant disease on invasive angiography (13). CTP images can be acquired with two different approaches: static or dynamic. In the CORE320 study, the CTP protocol used static acquisition method. The static CTP method, samples a snapshot of the iodine distribution in the blood pool and the myocardium over a short period of time, targeting either the upslope or the peak of contrast bolus. The notion behind this is that, at the upslope of the contrast, the difference in attenuation value of the ischemic and remote myocardium is at the maximum which enables for qualitative and semi-quantitative assessment of myocardial perfusion defects. The static CTP, however, does not allow for direct quantification of the myocardial blood flow (MBF). One of the drawbacks of static CTP lies in the acquirement of only one sample of data and the possibility of mistiming of the contrast bolus that results in poor contrast-to-tissue ratios by missing the peak attenuation (14). Output and flow rate of the contrast material may affect bolus timing. In addition, the acquisition of data from sequential heartbeats affects the attenuation gradient and may result in a heterogeneous iodine distribution, mimicking perfusion defects (15). Furthermore, the static CTP is limited in detection of balanced ischemia, where the perfusion of the entire myocardium is impaired and therefore there is no reference remote myocardium for comparison for semi-quantitative or qualitative static methods of CTP interpretation. Dynamic CT perfusion imaging uses serial imaging over time to record the kinetics of iodinated contrast in the arterial blood pool and myocardium. This technique allows for multiple sampling of the myocardium and the blood pool and creating time attenuation curves (TAC) by measuring the change in CT attenuation over time. Mathematical modelling of TACs permits for direct quantification of MBF. Despite its advantages, the use of dynamic CTP were limited in the past. A high temporal resolution and high number of detectors are required for dynamic CTP to allow for entire myocardial coverage, and in order to obtain multiple consecutive images at high heart rates(16,17). But the main challenge of dynamic CTP acquisition was the high radiation dose associated with this technique. Nevertheless, with the introduction of the cutting-edge 320 detector CT scanning systems with fast gantry rotation the issue of the cardiac coverage is eliminated(17). The second-generation 320-row scanners also permit the quantification of the MBF with dynamic CTP acquisition with relatively low-dose of radiation(18,19). In this study the investigators aim to evaluate the feasibility, safety and accuracy of the low-radiation dose dynamic myocardial CT perfusion compared to static CTP approach to detect hemodynamically significant coronary artery disease.


Clinical Trial Description

This will be a prospective study comparing the low-dose dynamic vs. static CTP combined with the CTA for detecting hemodynamically significant coronary artery stenosis. The aim of the study is to assess the feasibility, safety and accuracy of low-dose dynamic CTP following CTA. The study will enroll patients who have documented coronary artery disease and an indication for coronary angiography or CT angiography. Referred patients will be assessed for eligibility through phone calls followed by in-person interviews. Patents will be provided with the informed consent forms for CTA-CTP and iodine contrast if it is determined that participants are eligible for the study. Patients have the right to refuse to participate in the study and in that case participants will receive the regular care, per clinical guidelines. Baseline information will be collected from the patients after participants consent to participate in the study. Baseline data collection will happen at the same day that the patients will undergo CTA-CTP. The CTA-CTP acquisition takes less than 60 minutes after the patient is on the CT scanner table. Patient preparation time before patient is brought on the CT scanner depends on patients' heart rate and the time that takes to reduce patient's heart rate to a level that is appropriate for CTA-CTP acquisition. The blood sample will be obtained from the patients at the same day as CTA-CTP acquisition. Patients will be discharged to home at the same day participants undergo CTA-CTP. b. Study duration and number of study visits required of research participants. There will be only one visit required for the purposes of the study, during which the CTA-CTP acquisition will be completed, baseline information will be collected and the blood samples will be drawn. The study participants will be contacted through phone 3-days after CTA-CTP acquisition for follow-up. CT Imaging protocol Patients will have two 18-20 gauge intravenous lines placed, one preferably in an antecubital vein for contrast administration. The patient will be hydrated with normal saline intravenously (250 - 500 ml) prior to CT scanning. The patient will lie supine on the scanner table and be attached to a 12 lead electrocardiographic monitor and an automated blood pressure monitor. Baseline ECG, heart rate, and blood pressure will be recorded and reviewed by one of the study investigators. Due to resultant artifacts from precordial leads, the 12 ECG leads and electrodes will be removed and rhythm monitoring will continue using the 3 lead system attached to the scanners monitoring system during scanning. A physician will be present at all times during adenosine infusion and CT imaging. Patients may receive an oral and/or intravenous dose of metoprolol up to one hour prior to the CT. If the heart rate is >60 beats per minute, 75 mg (max 80 mg) of metoprolol will be given orally. If Heart rate remains >60 beats per minute at the scan acquisition then, intravenous beta blocker (metoprolol, propranolol or landiolol) 2.5 - 5.0 mg every 5 minutes will be administered to achieve a heart rate between <60 beats per minute as blood pressure tolerates under the supervision of a physician. Scout images for determining scanning range will be obtained in the anterior-posterior and lateral views. Patients with systolic blood pressure ≥110 will receive sublingual fast acting short lasting nitrates (e.g. nitroglycerin, isosorbide dinitrate). Patients will then be asked to hold their breath (approximately 10-15 seconds) and non-contrast CT imaging will be performed starting just cranial to the coronary ostia and extending just caudal to the apex of the heart in order to obtain a coronary calcium score. CT angiogram will be performed to evaluate the coronaries and myocardial perfusion at rest. Blood pressure will be checked and intravenous adenosine infusion (0.14 mg/kg/min) will begin with continuous heart rate and rhythm monitoring. After 5 minutes of adenosine infusion, contrast-enhanced CT perfusion imaging will be performed during a 4-5 ml/sec intravenous iodinated contrast (ISOVUE®-370) infusion. Total contrast dose for the entire protocol will not exceed 140 ml and will be based on patient's body size. Patients will be asked to hold their breath during scanning. Immediately following completion of the scan, the adenosine infusion will be discontinued. A twelve lead ECG and blood pressure measurement will be repeated after discontinuation of adenosine and reviewed by a physician. Intravenous hydration will be continued during recovery with normal saline for a total volume for the entire post scan of 250 to 500 ml if deemed appropriate by the supervising physician. 320-Detector CT Protocol for Combined Coronary Angiography and Perfusion Imaging 1. Coronary calcium scan will be performed using the following protocol: - No contrast. - CT Imaging: tube voltage = 120kV, tube current = 140 Milliampere (mA), gantry rotation speed = 0.35 seconds, slice thickness = 0.5 mm, rows = 256-320, range = 128-160 mm. X-ray tube will be on for a total of 0.35 seconds. Estimated radiation dose = 1.5 Millisievert (mSv). 2. Rest coronary arterial imaging Rest perfusion and coronary arterial imaging will be performed during a 4-5 ml/sec intravenous iodinated contrast (ISOVUE®-370) infusion. The rest CTA-dynamic CTP images will be started using a test bolus acquisition and accurate quantification of optimum timing for dynamic CTP and boost CTA acquisition and will continue for 20-30 sec using a ECG triggering method to allow acquiring the images only within 70-80% of the R-R interval, but not continuously. The parameters for the dynamic CTP image acquisition are the followings: For the heart rate of <60 bpm the tube voltage will be 80 kV and the tube current will be 100mA. Other parameters are: gantry rotation=0.275, range=120mm. The CTA and static CTP imaging will be performed as a boost scan during the dynamic CTP with the same tube voltage (80kV) but the tube current of 600mA within 70-80% of R-R interval. The boost timing will be quantified from test bolus acquisition. The average radiation dose for rest CTA and rest dynamic and static CTP acquisition is 3.69mSv. 3. Stress Myocardial Perfusion imaging 20 minutes after rest image acquisition Blood pressure will be checked and intravenous adenosine infusion will begin with continuous heart rate and rhythm monitoring. After 5 minutes of adenosine infusion, contrast-enhanced CT perfusion imaging will be performed during a 4-5 ml/sec intravenous iodinated contrast (ISOVUE®-370) infusion. The stress dynamic CTP images will be started using a test bolus acquisition and accurate quantification of optimum timing for dynamic CTP and boost CTA acquisition and will continue for 20-30 sec using a ECG triggering method to allow acquiring the images only within 70-80% of the R-R interval, but not continuously. The parameters for the stress dynamic CTP image acquisition are the followings: For the heart rate of <80 bpm the tube voltage will be 80 kV and the tube current will be 100mA. Other parameters are: gantry rotation=0.275, range=120mm. The stress static CTP imaging will be performed as a boost scan during the stress dynamic CTP with the same tube voltage (80kV) but the tube current of 600mA within 70-80% of R-R interval. The boost timing will be quantified from test bolus acquisition. The average radiation dose for stress dynamic and static CTP acquisition is 5.17mSv. The estimated average radiation dose for the entire cardiac computed protocol is 10.55 mSv and shall not exceed 15mSv. Beta-blockers will be used to control the heart rate and thus maintain the radiation dose as low as reasonably achievable. The total contrast dose will not exceed 140 ml. Depending on patient size, 50-70 ml of iodinated contrast will be used for each of rest and stress scans. In the event that the CT raw data are not readable at the Johns Hopkins University, a copy of the raw data (anonymized without patient identifiers) will be transferred to Toshiba Medical Systems for engineering support of image reconstruction in these isolated cases. Toshiba Medical Systems will perform the image reconstruction and return the raw data and the reconstructed image data to the Johns Hopkins University for image analysis. Within 3 weeks of the CT, the CT will be reviewed for non-cardiac findings by a locally qualified, institutionally approved cardiologist and reported to the patient's clinical physician and patient in a timely fashion preferably prior to or during the 30-day follow-up. c. Blinding, including justification for blinding or not blinding the trial, if applicable. Dynamic and static CTP images will be analyzed separately and when analyzing the CTP images with each method, the readers will be blinded to the results the other method. However the readers will have access to the results for CTA interpretation while reading the CTP images with either of static or dynamic methods. d. Justification of why participants will not receive routine care or will have current therapy stopped. The study will be only enrolling patients with an indication for CTA or invasive coronary angiography and will undergo these tests. So routine care will be delivered to the participants. 7. Study Statistics a. Primary outcome variable. The primary outcome measures will be feasibility, safety and accuracy of dynamic CTP-CTA compared to static CTP-CTA to detect hemodynamically significant coronary artery stenosis. The hemodynamically significant coronary artery stenosis will be defined as having at least one vessel with a ≥50% stenosis associated with perfusion defect in static CTP images. At the index visit, failure to complete the CTP protocol will constitute an incomplete study and such patients will be excluded from the per protocol analysis. All patients completing the CTP protocol and providing informed consent will be included in per-protocol analyses. All data from all consented patients who do not complete the CTP protocol will be included in the intent-to-diagnose analysis. Descriptive statistics will be given for all variables including indications for the test, demographics, patient history, CTA test information, dynamic and static CTP information. Categorical variables will be summarized as counts and percentages. All continuous variables will be summarized as means+/- the standard deviation followed by the median, minimum and maximum and 25th, 75th percentiles where needed. The frequency of the primary safety outcomes [death, myocardial infarction, unstable angina, ventricular tachycardia, asystole, severe bradycardia, allergic skin reactions, allergic respiratory reactions, hypotension, anaphylaxis and contrast induced nephropathy] will all be summarized; 95% binomial confidence intervals for the proportions of these outcomes will be calculated. The additional safety outcomes involving CTP complications will be summarized with frequencies and 95% confidence intervals for proportions. Radiation dose and efficiency measures (duration(s) involving the CTP procedure) will be summarized overall with median and 25th and 75th percentiles. Also minima and maxima will be provided. The investigators may explore possible associations between patient characteristics [demographics (gender, age), prior histories or indications] and the binary safety outcomes using contingency table methods, t tests or Wilcoxon Rank Sum, as appropriate. Associations between radiation dose and patient characteristics may be explored with nonparametric methods. The investigators may also explore possible relationships between the CTA stenosis categories (0%, 1-49%, 50-100%) and the dynamic and static CTP results. The occurrence of clinical events recorded at 30-day chart review will be related to the category of CTP final results (Normal, Probably Normal, Equivocal, Probably Abnormal and Abnormal) using methods for contingency tables which incorporate the natural ordering of CTP categories. The frequency of the studies with the adequate image quality for interpretation of dynamic CTP images will be reported as a measure is feasibility. This feasibility index will be also reported at the myocardial segment level and the frequency of Left Ventricular (LV) segments with adequate dynamic CTP image quality will be reported. The inter- and intra-reader reproducibility of dynamic CTP interpretation will be assessed using kappa statistics, intra-class correlation coefficients and Bland-Altman plot, as appropriate. The accuracy of the dynamic CTP for detection of hemodynamically significant coronary artery stenosis will be based on the area under the receiver operating characteristic (ROC) curve (AUC) with the static CTP results as the comparator. The correlation of the dynamic vs. static CTP will be also assessed in the categorical (Chi-squared test) and continuous (Spearman's correlation coefficient) scale. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03324308
Study type Interventional
Source Johns Hopkins University
Contact
Status Withdrawn
Phase N/A
Start date March 30, 2018
Completion date May 8, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A