Administrative data

NCT number NCT03057561
Other study ID # Pro00012234
Secondary ID
Status Enrolling by invitation
Phase N/A
First received
Last updated
Start date October 1, 2016
Est. completion date June 30, 2021

Study information

Verified date January 2019
Source The Methodist Hospital System
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This project is designed to demonstrate equivalence of Dotarem enhanced LGE-CMR (late gadolinium enhancement cardiac MRI) with Gadoviost enhanced LGE-CMR from the standpoint of visual image quality, quantitative image quality, and association with clinical outcomes.


Description:

Gadolinium-containing contrast agents (GdCAs) are intravenous agents used for contrast enhancement with magnetic resonance imaging (MRI) and with magnetic resonance angiography (MRA). The GdCAs (gadodiamide, gadopentetic acid, gadobenic acid, gadoxetic acid, gadoteridol, gadobutrol and gadoteric acid) have been in use for few decades for different types of MR scan varying from product to product, including liver, brain, and whole body scan.

Recently, there has been a great interest in employing contrast-related techniques to assess for fibrosis in the myocardium of the heart. As opposed to nuclear methods, viability assessment by MRI is a nonstress examination that provides high-resolution detail, including functional assessment of the left ventricle in approximately 30 minutes. Assessment of myocardial viability is performed using 5- to 20-minute delayed, gadolinium-enhanced MRI. On delayed MRI, there is a relatively decreased washout of the gadolinium contrast agent in areas of myocardium that have been replaced by fibrosis or scar. In normal viable myocardium, the gadolinium contrast agent washes out more rapidly than it does from the fibrosis or scar. Since the difference between normal and abnormal myocardium is based on washout kinetics, images that are delayed by 5 to 20 minutes after contrast injection will optimally depict the fibrosis or scar.

The differences in gadolinium enhancement on MRI of viable myocardium and fibrosis or scar have been known for many years. Recently, however, MRI pulse sequences have been developed that greatly improve the conspicuity of the enhanced areas of myocardium that have been replaced by fibrosis or scar. The pulse sequence used is an inversion-recovery prepared gradient-echo sequence. In this method, an inversion pulse is used to null the signal from normal myocardium. Myocardium that is replaced by fibrosis or scar retains gadolinium and shows very high signal intensity compared with the suppressed, darker myocardium.

Gadovist has been the standard gadolinium contrasts used in the U.S. in CMR imaging for the past few years. On the other hand, Dotarem, a widely used contrast agent in Europe, has been introduced to be used in the U.S. market.The sensitivity of Dotarem to that of Magnevist in determining the location and extent of scar in patients scanned with CMR will be Gadovist in this study.

The CMR laboratory at the Houston Methodist DeBakey Heart & Vascular Center is one of the largest dedicated CMR laboratories in the U.S. performing 3,000 clinical CMR procedures per year. The laboratory has been in existence since 2008 and is currently equipped with 2 dedicated MRI scanners: 1.5T Siemens Avanto and 3.0T Siemens Verio. Through a research agreement with Siemens Medical Solutions, the laboratory has access to numerous works-in progress sequences as they are developed. The laboratory is equipped with an MRI compatible patient monitoring system, infusion pump, and power injector and is staffed by a team of 5 dedicated CMR technologists, 2 clinical nurses, 1 CMR fellow, an MRI scientist, and 2 attending cardiologists.

One hundred twenty patients with known or suspected cardiovascular disease will be recruited for this study. Patients will be randomized (in a 1:1 fashion) to receive either Dotarem or Gadovist for LGE-CMR such that there will be 60 patients in the Dotarem cohort and 60 patients in the Gadovist cohort.


Recruitment information / eligibility

Status Enrolling by invitation
Enrollment 120
Est. completion date June 30, 2021
Est. primary completion date December 31, 2020
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Patients undergoing clinically referred CMR.

Exclusion Criteria:

1. Patients who are unable to give informed consent.

2. Individuals with severe claustrophobia.

3. Individuals unable to lie flat for 90 minutes (the anticipated amount of time to complete the MRI procedure).

4. Individuals who are pregnant.

5. Patients with implants or pacemakers.

6. Patients that have hypersensitivity to components of gadolinium.

7. Patients with renal failure.

8. Patients who had any trauma or surgery which may have left ferromagnetic material in the body.

Study Design


Intervention

Drug:
Cardiac MRI taken using contrast agent, Dotarem® (Gd-DOTA)
Gadolinium based contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI
Cardiac MRI with contrast agent, Gadovist
Brand of Gd-DO3A-butrol; contrast agent used in cardiac MRI scanning using 3.0 Tesla MRI

Locations

Country Name City State
n/a

Sponsors (2)

Lead Sponsor Collaborator
Dipan Shah Guerbet

Outcome

Type Measure Description Time frame Safety issue
Primary Compare visual image quality of LGE-CMR when performed with Dotarem or Gadovist in a randomized fashion. All LGE-CMR scans scoring for visual image quality using a 5-point scale: 1 = LV myocardium not visible, 2 = severe artifact interfering with ability to visualize LV myocardial borders limiting assessment for presence of LGE (poor), 3 = LV myocardial borders are well delineated but there is moderate artifact affecting ability to identify LGE (fair), 4 = LV myocardium is well delineated with minor artifacts affecting ability to identify LGE (good), 5 = LV myocardium well delineated with no artifacts affecting ability to identify LGE (excellent). Two years
Primary Compare quantitative signal enhancement of LGE when performed with Dotarem or Gadovist in a randomized fashion. Assessment of the intensity of hyperenhancement with Dotarem and Gadovist using a semi-automated computer software. Two Years
Primary Compare association of LGE and clinical cardiovascular outcomes when performed with Dotarem or Gadovistin a randomized fashion. Patient screened for outcomes (e.g. acute myocardial infraction, sudden cardiac death, heart failure, stroke, cardiovascular hemorrhage, other death from cardiovascular causes) Eight years
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A