Clinical Trials Logo

Clinical Trial Summary

Background: Cardiovascular disease (CVD) is one of the leading causes of morbidity and mortality among dialysis patients. Eotaxin-1(also known as Eotaxin and CCL11), an eosinophil-specific chemoattractant that plays a role in a variety of pathologic conditions including allergy, coronary heart disease, and inflammatory bowel disease. CCL11 has been shown to be overexpressed in human atherosclerotic lesions. Moreover, eotaxin-1 levels are higher in non-uremic coronary artery disease patients than in healthy individuals. Methods: The study will enrolled 400 hemodialysis patients. Patients are diagnosed with coronary artery disease based on clinical presentation and confirmed by angiography. Serum eotaxin-1 and 8-isoprostane levels are determined by enzyme-linked immunosorbent assay (ELISA). High-sensitivity cTnI immunoassays and albumin redox state by high-performance liquid chromatography are used for measurements. Aim: In this study, we aimed to determine the eotaxin-1 concentrations of patients with coronary artery disease and to investigate the role of eotaxin-1 and markers of myocardial injury.


Clinical Trial Description

Study Design and Patient Population This cross-sectional trial, and will be carried out in accordance with the Declaration of Helsinki and applicable regulations. The protocol will be sent to the institutional ethics committee and patients' written informed consent will be obtained. To be included in the study, patients will be at least 20-years-old and on outpatient HD for at least 3 months. All the patients were dialyzed three times a week with a high-flux membrane and bicarbonate dialysate solutions. Patients will excluded if they had an acute infection or malignancy. A total of 400 long-term HD patients are randomly invited and enrolled in the study. The medical records will thoroughly reviewed for each subject by a collaborating physician in the study. Information such as underlying kidney disease, cardiovascular disease history, and other comorbid illnesses are abstracted. A pre-existing history of CVD was defined as a history of CAD ( including a history of myocardial infarction, coronary artery angioplasty/stenting/bypass surgery, carotid endarterectomy/stenting), cerebrovascular disease (CVD, e.g., stroke), non-traumatic lower extremity amputation, and lower limb artery bypass surgery/angioplasty/stenting Measurements Predialysis blood samples are obtained on a mid-week day.Within 30 min after sampling, the remaining blood arecentrifuged at 3,000 g for 10 min, immediately aliquoted and frozen at-80 °C until further analysis. The total serum cholesterol is measured through the reaction of cholesterol esterase/cholesterol oxidase/peroxidase, using Hitachi 747 (Hitachi, Bohemia, NY, USA). HDL cholesterol is quantified after precipitation with polyethylene glycol at room temperature. Serum glucose concentrations are measured by the glucose oxidase method. Low-density lipoprotein cholesterol was calculated using the Friedewald formula. Total serum triglycerides were measured through the reaction of glycerol/ phosphate/oxidase and peroxidase. The serum levels of high-sensitivity C-reactive protein (hsCRP) are measured using a Behring Nephelometer II (Dade Behring, Tokyo, Japan). Serum levels of IL-6 and MCP-1 are measured by a commercially available enzyme-linked immunosorbent assay (Quantikine HS Immunoassaykit, R&D System, Minneapolis, MN, USA). Serum 8-isoprostane concentrations were measured using the ELISA assay (Cayman Chemical, Ann Arbor, Michigan, USA) with a detection limit of 3 pg/mL, according to the manufacturer's instruction. Serum eotaxin levels will be determined using a commercial ELISA kit (R&D systems, Minneapolis, MN, USA)according to the manufacturer's protocol. In brief, mouse antihuman antibody against eotaxin is used to capture eotaxin from plasma. Captured eotaxin is detected with biotynilated goat antihuman eotaxin antibody. After washing, plates are incubated with streptavidin-HRP, developed with appropriate substrate, and OD450 is determined using an ELISA plate reader. Measurements are done in duplicate in an assay able to detect 10 pg of eotaxin/ml. The intraand inter-assay coefficients of variation values are <4% and <6%, respectively. The Siemens Atellica IM High Sensitivity Troponin I assay (Siemens Healthineers) is a three-site sandwich immunoassay with a limit of detection of 1.6 ng/L and limit of quantification of 2.5 ng/L. The upper reference limit 99th centile was determined in 2007 samples from healthy individuals as 34 ng/L in women, and 53 ng/L in men, with a single threshold of 45 ng/L. In the reference range population, 75% of patients had values greater than the limit of detection. All measurements were undertaken at a central laboratory, who were blinded to all clinical information with results provided to the research team and linked to the trial database for analysis. The redox state of serum albumin was determined by fractionating it into human mercaptalbumin (HMA), human nonmercaptalbumin-1 (HNA-1), and human non-mercaptalbumin-2 (HNA-2) with high-performance liquid chromatography (HPLC). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06211244
Study type Observational
Source Tungs' Taichung Metroharbour Hospital
Contact Paik Seong Lim, PhD
Phone +886935045292
Email jamespslim@gmail.com
Status Not yet recruiting
Phase
Start date May 1, 2024
Completion date December 31, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions N/A