Clinical Trials Logo

Clinical Trial Summary

This registry is a large-scale epidemiological study (PREVASC) aimed at estimating the prevalence of symptomatic and asymptomatic valvular hear disease in men and women aged over 65 years randomly selected in Italy.


Clinical Trial Description

PREVASC is a cross-sectional, population-based study. Participating subjects are invited from the general population and underwent a physical examination and an electrocardiography and echocardiographic examination by a local cardiologist. A random sample of about 2000 subjects over 65 years will be considered for sampling. The sample size is determined on the basis of a priori criteria in order to estimate a prevalence of 3% [standard error (SE) ± 1.1] for VHD. Both clinical and demographic information will be collected to better characterize the invited population. Written informed consent for the clinical examination will be asked. Demographic variables, cardiovascular (CV) risk, clinical history, physical findings, and medications will be recorded in a Case Report Form (CRF) by physicians or trained nurses. Assessment of anthropometric measures, blood pressure, and heart rate will be performed according to MONICA recommendations. Overweight is defined as a body mass index (BMI) between 25 and 29.9 kg/m2. Obesity is defined as BMI ≥30 kg/m2. Symptoms and signs attributable to VHD will be evaluated and reported on the CRF by a dedicated expert physician in each site at the time of the physical examination. Echocardiography Complete Colour Doppler echocardiography will be performed in peripheral centers using commercially available machines according to a pre-defined protocol. Echocardiograms will be recorded in standard DICOM format on digital. The following parameters will be acquired: - Linear measurements of cardiac chambers will be obtained from the two-dimensional (2D) parasternal long axis view or, when available, from the M-mode parasternal short axis recording according to the recommendations of the European American Society of Echocardiography and the European Association of Cardiovascular Imaging []. - LV volumes will be obtained from the apical four-chamber view and the EF calculated by using the modified Simpson's rule method. - Left ventricular mass will be calculated according to the Devereux formula. - Left ventricular systolic function will be calculated using the formula for ejection fraction EF: EDV-ESV/EDV X100. - Also left atrium area or volume will be measured by the 4-chamber view. - Calcifications of the aortic valve and mitral apparatus will be quantified as light, moderate, or severe, according to a published approach. The bicuspid aortic valve will be searched for and recorded. Trans-aortic and trans-mitral gradients, as well as mitral, aortic, and tricuspid regurgitation, will be reported and quantified according to continuous wave Doppler and Color Doppler area of regurgitation or vena contracta (VC) width (light, moderate, severe), respectively. For quantitative measurement of mitral regurgitation and tricuspidal regurgitation PISA method will be used. For aortic regurgitation PHT will be adopted other than VC. The aortic valve area will be calculated using the continuity equation other than the planimetric area. Mitral valve area will be calculated using pressure half time (PHT) other than planimetric area. Pulmonary artery systolic pressure will be estimated according to standard method. - Doppler-derived indexes of transmitral flow and pulmonary vein flow, and tissue Doppler imaging of the lateral mitral annulus (E/e') will be used to define diastolic LVD. Peak early diastolic filling wave (E) velocity, peak atrial diastolic filling wave (A) velocity, and deceleration time of the E wave (DTE) will be measured at the tips of the mitral leaflets. The DTE will be calculated as the time from E to the time when the descent of E intercepts the zero line. The duration of the transmitral A wave velocity will also be measured. The peak velocity of pulmonary venous (PV) systolic (S), and diastolic (D) flow, the peak velocity of PV backward flow at atrial contraction (PVa), and the PVa wave duration (PVa dur) will be measured with the sample volume placed in the right upper pulmonary vein in the four-chamber axis view. The difference between the transmitral A wave duration (Adur) and PVa dur will be derived as an indirect index of increased LV filling pressures, according to the standard method. Tissue Doppler will be used to calculate the E/e' ratio. - All digital echocardiograms will be analyzed offline on a dedicated workstation by three independent observers, blind to clinical data, and reviewed by the same experienced reader. Measurements will be expressed as an average of three cycles in sinus rhythm and from three to five cycles in atrial fibrillation. Cardiologists and nurses will be trained locally according to standardized methodologies. Before enrolment begins, all participating centers will be required to perform and send an echo test to the Core Lab to verify the appropriateness of the acquisition procedure. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05892588
Study type Observational [Patient Registry]
Source Azienda Ospedaliero-Universitaria Careggi
Contact Nazario NC Carrabba, phisician
Phone 00393355939482
Email carrabban@aou-careggi.toscana.it
Status Recruiting
Phase
Start date June 1, 2022
Completion date July 1, 2023

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Active, not recruiting NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease