View clinical trials related to Aneurysm.
Filter by:The goal of this observational study is to evaluate the Thoraflex Hybrid device alone and in combination with the RelayPro NBS stent-graft in the treatment of aortic disease affecting the aortic arch and descending aorta with or without involvement of the ascending aorta. Patients who undergo treatment with the Thoraflex Hybrid device with or without extension with a RelayPro NBS stent-graft will be eligible for enrolment and study activities and follow-up regime will follow standard care at each participating site. Participant involvement in the study will last for a total of 10 years from the point at which the Thoraflex Hybrid device is placed.
This is a multi-center, prospective, propensity matched twin armed study conducted on 50 patients in the experimental arm followed for 18 months after intervention evaluating cost effectiveness, safety and efficacy of therapy.
In this project the investigators study the safety and efficacy of the pipeline embolization device with vantage technology in treatment of unruptured brain aneurysms
Abdominal aortic aneurysm (AAA) is a localized dilatation of a segment of the aorta artery in its abdominal portion. It affects 1.7% of men aged 65 years and older. In the high-risk population (male smokers aged 65-75 years), its prevalence is estimated to be between 2.8 and 9%. Mortality of ruptured AAAs is high (80% of deaths before hospitalization or perioperatively), whereas mortality of scheduled procedures for unruptured AAAs is less than 5%. AAA screening has been shown to significantly reduce the specific mortality rate in the medium and long term. The French National Authority for Health (HAS) recommends targeted screening for AAA by ultrasound at the radiologist. The target population is male smokers or former smokers aged 65 to 75 years, as well as all persons aged 50 to 75 years with a family history of AAA. Despite recommendations, the rate of access to targeted screening appears low. Ultrasound screening for AAA is a rapid, noninvasive, and reproducible test. It relies primarily on the measurement of the maximum diameter of the abdominal aorta in cross-section. It has been demonstrated that the learning of the ultrasound screening procedure for AAA is very fast and that the performance of non-radiologists trained in this procedure alone is similar to that of radiologists. In addition, new ultra-portable ultrasound devices, inexpensive and with validated performances have appeared on the market in the last few years, making it possible to equip general practitioners (GPs). We propose a simplified care pathway for AAA screening, by equipping GPs with an ultra-portable ultrasound scanner and by training them to perform the screening procedure, which will be performed in the office or at the patient's home, during a usual consultation of general medicine. Our hypothesis is that this new organization will allow better access to screening for the target population, at a lower cost, compared to the current screening method recommended by the HAS (referral of the patient to the radiologist).
The goal of this multicenter, observational cohort study is to evaluates the clinical effectiveness of a single-renal scallop custom-made stent-graft (TREO, Terumo Aortic, Sunrise, FL) to treat "hostile" AAA with mismatched renal arteries as actual standard of care in this Vascular Unit The main question it aims to answer are: if a dedicated devices could improve the results in the endovascular treatment of patients suffering to infrarenal abdominal aortic aneurism with a mismatched takeoff of the renal arteries. Participants responding to inclusion criteria will be treated as best clinical practice with a custom made device with a single scallop for the renal artery. The minimum follow-up requested, as standard clinical practice, was: 3-months, 12-18 months- and 5-years CTA; clinical and DUS examination at 6- and 12- and 36-months after the intervention and yearly thereafter. No comparison group was present.
Intracranial aneurysm is the main cause of subarachnoid hemorrhage, and the incidence of subarachnoid hemorrhage in Chinese population is about 5%. The intervention of unruptured intracranial aneurysms is controversial because of its great harm after natural rupture and bleeding, and about a quarter of patients still have poor prognosis through existing invasive treatment methods. How to accurately determine the instability risk of unruptured intracranial aneurysms is the key to resolve this controversy. In previous studies, the stability of intracranial aneurysms involves many characteristics, and the sample size is small. Most of them are retrospective studies and studies on the status after change (rupture/growth). Therefore, the relevant risk factors are not clear at present, and there is still a lack of reliable prediction model. Based on the above facts, this study proposed based on the national hundred regional medical institutions set up the network registration platform of unruptured intracranial aneurysms, real time and openness of Internet, through the way of case resource sharing build unruptured intracranial aneurysm queue, collecting clinical characteristics, imaging features, hemodynamic detection of biological samples and the results of the analysis data, And observe them for two years. The artificial intelligence platform of Tonglian Medical Health was used to integrate and analyze and learn all the data, and then the risk factors related to the stability of intracranial aneurysms within two years were obtained, and the stability prediction model of unruptured intracranial aneurysms was constructed. This study will build the largest network registration platform and population follow-up cohort of unruptured intracranial aneurysms in China, and put forward a prediction model for the stability of unruptured intracranial aneurysms by integrating the multi-dimensional factors of intracranial aneurysms, so as to provide a powerful auxiliary judgment tool for the clinical decision-making of this disease.
This project seeks to determine if certain anatomic factors, specifically tortuous and non-conformable iliac arteries, may predict device complications, including seal zone failure, type III endoleak, and occlusion. Approximately 400 subjects from 5 academic centers across the United States, Europe, and Asia will be included in this study. Various markers of pre- and post-treatment iliac anatomy will be measured using CT imaging, and clinical events will be reported by academic centers. The relationship of imaging data to patient demographics will then be assessed alongside anatomic and demographic predictors of non-conformability.
The aorta distributes cardiac stroke volume into the whole body through its finetuned conductance function, that is propagation and modulation of flow pattern. Physicomechanic properties of the aortic wall assure continuous and homogenous blood flow distribution to organs. The physicomechanic properties of the aortic wall are heterotopic: The collagen/elastin ratio doubles in the abdominal aorta as compared to the thoracic aorta. Malfunction of aortic conduction due to large artery stiffening (LAS) leads to premature wave reflection and excess pulsatility which translate into organ damage in low-resistance beds. The regional heterogeneity of aortic physicomechanic properties and their histomorphological substrate leading to altered regional hemodynamics are not well investigated. Within the PHaRAo population, there is a spectrum of higher and lower risk patients. The aim of this cohort study is to collect prospectively and systematically clinical research data from PHaRAo patients. This cohort study is an open-end observational study to identify master switches in aortic disease
The objective of the study is to assess the stent stability and durability as well as the seal of the stent graft during the cardiac cycle and over time as well as to evaluate safety and clinical performance of the E-tegra Stent Graft System used in endovascular treatment of infrarenal aortic aneurysm.
In recent years, researches on the natural history and risk factors of intracranial unruptured aneurysms have become a hot topic at home and abroad. However, risk factors for aneurysm rupture is still unclear yet. The investigators' preliminary study focused on constructing a rupture risk prediction system for intracranial unruptured aneurysm in the investigators' single center. The investigators' result showed that three significant factors (sex, abnormal serum tumor necrosis factor (TNF)-α and coincidence of thin-walled regions (TWR) and normalized wall shear stress (NWSS)) stood out by using logistic regression to explore the rupture risk factors of intracranial unruptured aneurysms, which could help guide the clinical treatment of intracranial unruptured aneurysms. This study is to evaluate and improve the rupture predict model of intracranial unruptured aneurysm in multi-neurosurgical centers.