View clinical trials related to Aneurysm.
Filter by:This research study is being done to test the effectiveness of a new generation FDA approved device for treating aneurysms compared to the current standard device for endovascular aneurysm treatment which is bare platinum coils. Endovascular procedures are a form of minimally invasive surgery, which is performed on blood vessels. The technique involves the introduction of a catheter which is a long, thin, flexible, hollow plastic tube through the skin into a large blood vessel. Typically the chosen blood vessel is the femoral artery found near the groin. The catheter is then maneuvered through the body to the location of the aneurysm in the brain using image guidance. Coils are delivered into the aneurysm through the catheters. Once the coils are delivered in the aneurysm, they are detached from the catheter. This is repeated until enough coils fill the aneurysm, blocking the blood flow to the aneurysm. The body responds by forming blood clots around the coil(s), which helps block the flow of blood into the aneurysm and keeps the vessel from rupturing or leaking. This study will compare the study device to the standard bare platinum coil to see which is better at preventing future rupturing or leaking. The study device is called the HydroCoil Embolization System and this study is a post-market clinical trial. About 600 subjects from multiple institutions will take part in this study.
This is an observational Registry designed to obtain early data on the use of the GORE® EXCLUDER® AAA Endoprosthesis with C3 Delivery System.
Study of the prevalence of Abdominal Aortic Aneurysms (AAA) (> 3 cm) in patients with echocardiography (transthoracic or) during a specific day, with cardiologists in France. This is a cross-sectional epidemiological investigation, assembling evidence from a routine ultrasound screening for AAA at the waning of echocardiograms performed during a specific day. The study will be offered a list of centers selected by the Scientific Committee in the complete list of locations being in France, the subsidiary of echocardiography Echocardiography of French Society of Cardiology. These centers will be 500 in number representative of the French centers, geographically and by type of centers.
The purpose of this study is compare two different surgical treatments of splenic artery aneurysms: open and laparoscopic approach.
ClarityIQ is a novel X-ray imaging technology, that combines advanced real-time image noise reduction algorithms, with state-of-the-art hardware to reduce patient entrance dose significantly. This is realized by anatomy-specific optimization of the full acquisition chain (grid switch, beam filtering, pulse width, spot size, detector and image processing engine) for every clinical task individually. Furthermore, smaller focal spot sizes and shorter pulses are used, which are known to positively influence image quality . The final effect on the clinical image quality is investigated in this study.
The purpose of the study is to demonstrate the long term safety and effectiveness of the Endurant Stent Graft System for the endovascular treatment of infrarenal abdominal aortic aneurysms in a post-approval environment, through the endpoints established in this protocol. The clinical objective of the study is to evaluate the long term safety and effectiveness of the Endurant Stent Graft System assessed at 5 years through freedom from Aneurysm-Related Mortality (ARM).
This is a prospective observational post-market study of subjects receiving the Ovation™ or Ovation Prime™ Abdominal Stent Graft System ("Ovation™ or Ovation Prime™ Abdominal Stent Graft System Post-Market Study") in the treatment of abdominal aortic aneurysms (AAA). The Ovation™ or Ovation Prime™ Abdominal Stent Graft System Post-Market study is intended to expand the clinical knowledge base by collecting data on subjects treated with the Ovation™ or Ovation Prime™ Abdominal Stent Graft System in actual clinical practice following commercial approval.
This is a prospective multicenter observational study with 20 patients to evaluate the performance of SCITECH stent for treatment of AAA. Will be enrolled the patient demographics, laboratory tests, medical history, clinical evaluation, physical examination, adverse events. The benefits and risks of the study should be explained before any specific test or procedure of the study. The written consent must be obtained from the patient. No action specifies the study should be performed while the patient has not signed the form of consent.
ThoraflexTM is designed for the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta. Each system is advanced from a transfemoral or transiliac approach over a 0.035" guidewire and positioned under fluoroscopic control. If necessary, an arterial conduit technique may be required to allow access to the arterial system. The soft tapered tip allows atraumatic insertion into the vessel, while the catheter and sheath are designed to provide excellent flexibility and control through tortuous arterial anatomy. Each individual stent graft device is supplied sterile and pre-loaded in a single-use delivery system. The stent graft is a self-expanding endoprosthesis constructed of a thin wall woven polyester and nitinol ring stents, which are attached to the fabric with braided polyester sutures. The delivery system central catheter is a stainless steel braided co-extrusion of polytetrafluoroethylene (PTFE) and polyester elastomer, designed to provide significant torque control and strength, while also maintaining superior flexibility. The outer sheath is made in a tri-layer construction consisting of a PTFE liner, a stainless steel flat braid layer and a polyester elastomer outer jacket with a hydrophilic lubricant coating. These materials provide very low friction force during device insertion and deployment together with enhanced flexibility of the delivery system. The handle components are moulded from thermoplastic polyurethane. The materials of the endoprosthesis are identical to those of the current Conformité Européenne (CE) marked Vascutek Ltd. AnacondaTM Stent Graft System intended for abdominal aortic aneurysm repair. The materials of the delivery system are well established in medical applications. The design of ThoraflexTM is based on the same principles as other clinically established thoracic endovascular devices. The endoprosthesis is constructed of self-expanding nitinol stents and a polyester tube graft. Four proximal hooks anchor the endoprosthesis within the aorta. Unlike existing thoracic endovascular devices, the delivery system of ThoraflexTM allows repositioning of the endoprosthesis so that the optimal deployment position can be enhanced. The intended use of ThoraflexTM is the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta, which is identical to other CE approved thoracic endovascular devices.
The aim of this study is to prospectively compare the perioperative mortality severe morbidity and the costs of endovascular versus conventional surgical repair of type 1, 2 and 3 thoracal abdominal aortic aneurysms.