Type 2 Diabetes Clinical Trial
Official title:
Validation Study for the Alertgy Non-invasive Continuous Glucose Monitor
Diabetes mellitus (DM) affects 30 million people in the United States. To achieve glucose control, most patients are prescribed glucose meters by their physicians. Obtaining glucose levels in this manner necessitates cleaning the fingers, attaching a lancet to a device (or simply using a lancet if a device is not available), pricking the finger with a lancet, placing a drop blood on a strip, and awaiting the readout that results after some chemical reactions. Thereafter, the lancet has to be disposed of in a safe receptacle and the finger has to be blotted to stop the blood from oozing. The anxiety, pain, and tedious process have led researchers to develop other means of checking glucose levels. There are now continuous glucose monitoring systems (CGMS) that entail inserting a subcutaneous sensor that sends readings through a transmitter. These CGMs may or may not need calibration with a fingerstick glucose reading, and the subcutaneous sensor still has to be changed every 10 -14 days. The Alertgy non-invasive continuous glucose monitor (ANICGM) is a device that does not entail any subcutaneous insertion of a sensor. It is strapped on to the wrist, and glucose readings are given based on subcutaneous signals. In 2001, a non-invasive device called Glucowatch Biographer was introduced that also involved subcutaneous signals without needing a subcutaneous insertion. However, for various reasons such as long calibration period and reading inaccuracies, the product did not take off. The ANICGM is a promising device that might overcome the limitations of existing and previous methods of non-invasive glucose measurement.
The ANICGM uses a weak electromagnetic field generated by its wrist band sensor to look into the body to produce a spectrum that provides a measurement of blood glucose present in the wrist area of the body. The core sensing technology used is dielectric spectroscopy, and has been shown capable of measuring blood glucose, non-invasively, in a laboratory environment. The system uses proprietary and patented dielectric materials and signal processing to enhance performance in both selectivity and sensitivity for blood glucose measurement. Much like how a MRI uses a strong magnetic field and its interaction with the body to create a picture of what is inside, the ANICGM uses a safe weak low frequency radiofrequency field to take a picture of a person's chemical spectrum, some of it specific only to blood glucose. The device sends and receives back signals from the wrist area that are used to generate a dielectric spectrum once every 6 seconds. The POC BG using the Accuchek Inform II will be used to provide calibration values for the ANICGM every 5 minutes in mg/dL, during the calibration process. The POC BG levels will be entered into the Alertgy laptop and a proprietary calibration program will be used to analyze the spectral data collected and will generate a calibration algorithm. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT05219994 -
Targeting the Carotid Bodies to Reduce Disease Risk Along the Diabetes Continuum
|
N/A | |
| Completed |
NCT04056208 -
Pistachios Blood Sugar Control, Heart and Gut Health
|
Phase 2 | |
| Completed |
NCT02284893 -
Study to Evaluate the Efficacy and Safety of Saxagliptin Co-administered With Dapagliflozin in Combination With Metformin Compared to Sitagliptin in Combination With Metformin in Adult Patients With Type 2 Diabetes Who Have Inadequate Glycemic Control on Metformin Therapy Alone
|
Phase 3 | |
| Completed |
NCT04274660 -
Evaluation of Diabetes and WELLbeing Programme
|
N/A | |
| Active, not recruiting |
NCT05887817 -
Effects of Finerenone on Vascular Stiffness and Cardiorenal Biomarkers in T2D and CKD (FIVE-STAR)
|
Phase 4 | |
| Active, not recruiting |
NCT05566847 -
Overcoming Therapeutic Inertia Among Adults Recently Diagnosed With Type 2 Diabetes
|
N/A | |
| Recruiting |
NCT06007404 -
Understanding Metabolism and Inflammation Risks for Diabetes in Adolescents
|
||
| Completed |
NCT04965506 -
A Study of IBI362 in Chinese Patients With Type 2 Diabetes
|
Phase 2 | |
| Recruiting |
NCT06115265 -
Ketogenic Diet and Diabetes Demonstration Project
|
N/A | |
| Active, not recruiting |
NCT03982381 -
SGLT2 Inhibitor or Metformin as Standard Treatment of Early Stage Type 2 Diabetes
|
Phase 4 | |
| Completed |
NCT04971317 -
The Influence of Simple, Low-Cost Chemistry Intervention Videos: A Randomized Trial of Children's Preferences for Sugar-Sweetened Beverages
|
N/A | |
| Completed |
NCT04496154 -
Omega-3 to Reduce Diabetes Risk in Subjects With High Number of Particles That Carry "Bad Cholesterol" in the Blood
|
N/A | |
| Completed |
NCT04023539 -
Effect of Cinnamomum Zeylanicum on Glycemic Levels of Adult Patients With Type 2 Diabetes
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Enrolling by invitation |
NCT05530356 -
Renal Hemodynamics, Energetics and Insulin Resistance: A Follow-up Study
|
||
| Completed |
NCT03960424 -
Diabetes Management Program for Hispanic/Latino
|
N/A | |
| Completed |
NCT04097600 -
A Research Study Comparing Active Drug in the Blood in Healthy Participants Following Dosing of the Current and a New Formulation (D) Semaglutide Tablets
|
Phase 1 | |
| Completed |
NCT05378282 -
Identification of Diabetic Nephropathy Biomarkers Through Transcriptomics
|
||
| Active, not recruiting |
NCT06010004 -
A Long-term Safety Study of Orforglipron (LY3502970) in Participants With Type 2 Diabetes
|
Phase 3 | |
| Completed |
NCT03653091 -
Safety & Effectiveness of Duodenal Mucosal Resurfacing (DMR) Using the Revita™ System in Treatment of Type 2 Diabetes
|
N/A |