Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05754281
Other study ID # STUDY00000130
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date February 3, 2023
Est. completion date December 31, 2025

Study information

Verified date March 2024
Source Joslin Diabetes Center
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The purpose of this study is to evaluate the accuracy of the Cambridge Medical Technologies, LLC second generation (2nd Gen) LabPatch glucose sensing system compared to a laboratory glucose analyzer (YSI 2300 STAT Plus) and 2 commercial glucometers, OneTouch Verio and Freestyle Lite. The primary endpoint of this study is the mean absolute relative difference (MARD) for 2nd Gen LabPatch system compared to each of the above mentioned glucose references over a 6 hour outpatient visit.


Description:

In a pilot study conducted previously by our group using the prototype 1st generation LabPatch system (PRECISION study, 2016-31), we found that LabPatch glucose measurements strongly correlated with those of YSI, OneTouch Verio, and Freestyle lite in a sample of 30 subjects (Tomah et al Diabetes Jun 2020, 69 (Supplement 1) 885-P). However, we observed significant inter- and intra-subject variability of LabPatch glucose measurements. Factors that may have contributed to this variability include: manual manufacturing of the 1st Gen LabPatch circuit chips and/or variability in the pressure applied by subjects on the circuit chip at each measurement. To control for these variables with the goal of improving overall accuracy, Cambridge Medical Technologies, LLC significantly improved and completely automated the manufacturing process of the circuit chips. In addition, the system has been miniaturized to a more user-friendly layout and with a clasp unit to control for pressure applied by the subject finger on the circuit chip. The 2nd Gen LabPatch system consists of: I. The 2nd Gen LabPatch chip which lies in the center of a clasp unit. The chip measures approximately 15.7 mm [0.618"] x 15.7 mm [0.618"]. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact II. A LabPatch clasp device III. A wire that connects the clasp unit to a Windows tablet which will communicate with the clasp via an application. Each data point will be viewed on the tablet and the application will also have some limited graphing capabilities to view trends of previous measurements The system has been previously tested on 10 human subjects with type 1 diabetes, each for six hours, at the Georgetown University Medical Center under clinical conditions supervised by a medical team including an endocrinologist and dermatologist. The test confirmed the absence of pain or abnormal physical sensation and that the operation of the device causes no tissue damage,instigates no neural sensation for the subject, and leaves no blemish on the skin. No skin damage incurred by the LabPatch operation was detected. The 2nd Gen LabPatch system is an in vitro diagnostic device (IVD), does not have significant risk and is therefore exempted from the IDE requirements. In addition, the device uses an in vitro diagnostic technology that does not create adverse events and therefore a data safety monitoring board (DSMB) is not requited.


Recruitment information / eligibility

Status Recruiting
Enrollment 60
Est. completion date December 31, 2025
Est. primary completion date September 30, 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria: 1. Subject has voluntarily signed and dated an informed consent form, approved by an Institutional Review Board/Independent Ethics Committee, and provided Health Insurance Portability and Accountability Act authorization (HIPAA) or other privacy authorization prior to any participation in study. 2. Subject is between 18 and 75 years of age. 3. Subject is diagnosed with type 1 diabetes or type 2 diabetes for =3 months and is being treated with insulin injections in the form of multiple daily injections or through insulin infusion pump. 4. Subject is a male or a non-pregnant and non-lactating female, at least 6 weeks postpartum prior to screening visit. A urine pregnancy test is required for all female subjects unless she is not of childbearing potential, defined as postmenopausal for at least one year prior to screening visit or surgically sterile (bilateral tubal ligation, bilateral oophorectomy, or hysterectomy). Exclusion Criteria: 1. Subject is pregnant or lactating. 2. Subject is not treated with insulin. 3. Subject has/had acute or chronic, contagious, infectious disease 4. Subjects with history of blood-born chronic viral infection (e.g. Hepatitis C and HIV) 5. Subject has/had clotting or bleeding disorders or other hematological disease. 6. Subject has an active malignancy (excluding the following dermal malignancies: basal cell carcinoma, squamous cell carcinoma, carcinoma in-situ of the cervix). 7. Subject had a recent cardiovascular event (e.g., myocardial infarction, stroke) = six months prior to screening visit; or stated history of congestive heart failure.

Study Design


Intervention

Device:
2nd Gen LabPatch Glucose Sensing System
I. The 2nd Gen LabPatch chip which lies in the center of a clasp unit. The chip measures approximately 15.7 mm [0.618"] x 15.7 mm [0.618"]. The chip has a telescopic micropipette which draws interstitial fluid to be analyzed for glucose levels. The chip is also able to measure skin temperature to ensure appropriate skin contact II. A LabPatch clasp device III. A wire that connects the clasp unit to a Windows tablet which will communicate with the clasp via an application. Each data point will be viewed on the tablet and the application will also have some limited graphing capabilities to view trends of previous measurements

Locations

Country Name City State
United States Joslin Diabetes Center Boston Massachusetts

Sponsors (2)

Lead Sponsor Collaborator
Joslin Diabetes Center Cambridge Medical Technologies, LLC

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Mean absolute relative difference (MARD) Blood glucose values (mg/dL) from the LabPatch system and reference YSI, One Touch Verio, and FreeStyle Lite will be used to report the mean absolute relative difference (MARD) in Percentage (%). Baseline, every 15 minutes for a total of 6 hours
See also
  Status Clinical Trial Phase
Completed NCT02771093 - An Exploratory Study of the Effects of Trelagliptin and Alogliptin on Glucose Variability in Patients With Type 2 Diabetes Mellitus Phase 4
Completed NCT02545842 - Assessment Study of Three Different Fasting Plasma Glucose Targets in Chinese Patients With Type 2 Diabetes Mellitus (BEYOND III/FPG GOAL) Phase 4
Recruiting NCT03436212 - Real-Life Home Glucose Monitoring Over 14 Days in T2D Patients With Intensified Therapy Using Insulin Pump. N/A
Completed NCT03244800 - A Study to Investigate Different Doses of 0382 in Overweight and Obese Subjects With Type 2 Diabetes Mellitus. Phase 2
Completed NCT03960424 - Diabetes Management Program for Hispanic/Latino N/A
Withdrawn NCT02769091 - A Study in Adult Patients With Nonalcoholic Steatohepatitis Who Also Have Type 2 Diabetes Phase 2
Recruiting NCT06065540 - A Research Study to See How Well CagriSema Compared to Semaglutide, Cagrilintide and Placebo Lowers Blood Sugar and Body Weight in People With Type 2 Diabetes Treated With Metformin With or Without an SGLT2 Inhibitor Phase 3
Recruiting NCT05008276 - Puberty, Diabetes, and the Kidneys, When Eustress Becomes Distress (PANTHER Study)
Completed NCT04091373 - A Study Investigating the Pharmacokinetics of a Single Dose Administration of Cotadutide Phase 1
Completed NCT03296800 - Study to Evaluate Effects of Probenecid, Rifampin and Verapamil on Bexagliflozin in Healthy Subjects Phase 1
Recruiting NCT06212778 - Relationship Between Nutritional Status, Hand Grip Strength, and Fatigue in Hospitalized Older Adults With Type 2 Diabetes Mellitus.
Completed NCT05979519 - Fresh Carts for Mom's to Improve Food Security and Glucose Management N/A
Recruiting NCT05579314 - XW014 in Healthy Subjects and Patients With Type 2 Diabetes Mellitus (T2DM) Phase 1
Completed NCT03859934 - Metabolic Effects of Melatonin Treatment Phase 1
Terminated NCT03684642 - Efficacy and Safety of Efpeglenatide Versus Dulaglutide in Patients With Type 2 Diabetes Mellitus Inadequately Controlled With Metformin Phase 3
Completed NCT03248401 - Effect of Cilostazol on Carotid Atherosclerosis Estimated by 3D Ultrasound in Patients With Type 2 Diabetes Phase 4
Completed NCT03644134 - A Personalized Intervention to Manage Physiological Stress and Improve Sleep Patterns N/A
Completed NCT05295160 - Fasting-Associated Immune-metabolic Remission of Diabetes N/A
Completed NCT02836873 - Safety and Efficacy of Bexagliflozin in Type 2 Diabetes Mellitus Patients With Moderate Renal Impairment Phase 3
Completed NCT02252224 - Forxiga (Dapagliflozin) Regulatory Postmarketing Surveillance