Clinical Trials Logo

Tachycardia clinical trials

View clinical trials related to Tachycardia.

Filter by:

NCT ID: NCT00770484 Completed - Clinical trials for Postural Tachycardia Syndrome

Effect of Exercise in OI

Start date: November 2008
Phase: N/A
Study type: Interventional

The main limitation patients with orthostatic intolerance (OI, or postural tachycardia syndrome, POTS) have to exercise is related to their increase in heart rate when standing. Main pharmacological treatment today is aimed at reducing heart rate with the use of betablockers (propanolol), this theoretically could also improve their exercise capacity; if their heart rate do not increase as much with the medication, they could exercise more. In addition, it has been suggested that in healthy volunteers subjected to head down tilt for 2 weeks (situation that produces a "simulated" transient POTS-like state) a single bout of intense exercise can improve orthostatic tolerance the day after exercising. The mechanisms involved in such response are not that clear but could be an increase in plasma volume already diminished in POTS patients. It seems likely that the same could be true for POTS patients. The purpose of the present study are to pharmacologically improve the amount of exercise POTS patients can perform by reducing their baseline heart rate (specific aim 1) and to evaluate next day heart responses to an acute bout of intense exercise. Therefore, the specific aims of this study are: 1. To test the hypothesis that lowering heart rate response with propanolol will result in an increase in exercise capacity. 2. To test the hypothesis that a single bout of exercise will result in an improvement in orthostatic tolerance the day after exercising.

NCT ID: NCT00746564 Completed - Syncope Clinical Trials

Study of New Implantable Loop Recorder

Start date: September 2008
Phase: N/A
Study type: Interventional

The goal of this IDE clinical study is to evaluate the quality of the cardiac signal recordings obtained by the St. Jude Medical (SJM) Confirm Implantable Cardiac Monitor (device).

NCT ID: NCT00745745 Completed - Clinical trials for Ventricular Tachycardia

Septal Positioning of Ventricular Implanted Cardioverter Defibrillator (ICD) Leads

SPICE
Start date: August 2008
Phase: N/A
Study type: Interventional

This clinical trial is a multi center, prospective, randomized, parallel study designed to compare septal to apical ICD lead placement.

NCT ID: NCT00730548 Completed - Heart Failure Clinical Trials

Compare Remote Patient Management and Standard Care in CRT-D and ICD-patients to Assess the Effect on Heart Failure

ConnectOptiVol
Start date: November 2007
Phase: N/A
Study type: Interventional

This pilot study is to prospectively evaluate the benefit of clinicians being able to access ICD device information in a timelier manner and treat fluid overload with a pre-defined pattern using the Medtronic OptiVol, Medtronic CareAlerts and Medtronic CareLink in Conexus-enabled devices (remote arm) as compared to the same devices without Medtronic OptiVol, Medtronic CareAlerts and Medtronic CareLink available to the treating physician (standard arm).

NCT ID: NCT00729703 Completed - Tachycardia Clinical Trials

Optimal Anti-tachycardia Therapy in Implantable Cardioverter-defibrillator (ICD) Patients Without Pacing Indications

OPTION
Start date: June 2006
Phase: Phase 4
Study type: Interventional

This study evaluates the impact of a new pacing mode avoiding unnecessary ventricular stimulation in combination with advanced dual chamber detection with slow VT management on the clinical outcome for hospitalization and mortality and inadequate therapy in medically stable, ICD-indicated patients with impaired left ventricular function (LVEF ≤ 40%) who do not have pacing indications and no indication for Cardiac Resynchronization Therapy (CRT). It compares a new pacing mode avoiding ventricular stimulation when not needed combined with dual chamber detection with a pure ventricular back up pacing and single chamber detection criteria with pure ventricular back up pacing. Therapies are compared in a prospective, randomized, single-blinded, parallel trial with a 24-month randomized treatment period. Randomization follows a 1:1 ratio. ICD therapy is enabled for all patients throughout the study. All patients receive optimal drug therapy for arrhythmia and heart failure treatment.

NCT ID: NCT00729235 Completed - Clinical trials for Biventricular Tachycardias

Biventricular Tachycardias Outcome Trial

BITAC
Start date: May 2006
Phase: Phase 4
Study type: Interventional

This clinical investigation is a device-based open, prospective, multicenter two-arm randomized trial, comparing patients who are treated in the slow VT zone versus patients who are not treated in that zone. The device intended to be used is the OVATIOTM CRT model 6750 but future generation of Sorin Group/ ELA Medical devices may be used provided they are CE marked. Ethics committees and health authorities will be informed prior to any use of a newer device if applicable. All patients will have a 3-zone detection configuration programmed. The slow VT zone will be defined by programming the detection parameters as follows: - Slow VT detection rate: 100 bpm (or if the resting rate is higher than 80 bpm, we recommend to adjust this parameter to: resting rate + 30 bpm) - VT detection rate: 150 bpm PARAD+ will be the first choice for SVT/ST and VT discrimination in the VT zones. The Fast VT and VF limits are left to investigator's judgment. Therapy on VT, fast VT and VF are also left to the investigator's judgment. Patients will be randomized at implant to have the slow VT zone programmed as a monitoring zone (monitoring arm) or to have therapies programmed within the slow VT zone (therapy arm). The randomization table will be generated by Sorin Group/ELA Medical.

NCT ID: NCT00728026 Completed - Clinical trials for Irritable Bowel Syndrome

Autonomic Profiles in Pediatric Patients With Cyclic Vomiting Syndrome (CVS), Irritable Bowel Syndrome (IBS),Postural Orthostatic Tachycardia Syndrome (POTS), Functional Abdominal Pain (FAP) or Chronic Nausea

Start date: June 2008
Phase: N/A
Study type: Observational

Retrospectively review the charts of all children who had heart rate variability, deep breathing test, valsalva maneuver, tilt table test, thermoregulatory sweat testing, quantitative sudomotor axon reflex test (QSART) completed and were cared for at Children's Hospital of Wisconsin.

NCT ID: NCT00721136 Completed - Atrial Fibrillation Clinical Trials

Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation

Start date: September 2007
Phase: N/A
Study type: Interventional

Patients requiring long term anticoagulation often undergo transition of their warfarin to heparin in anticipation of invasive surgical procedures such as pacemaker or ICD implantation. This may require inpatient hospitalization several days prior to and after the procedure, potentially increasing medical costs and patient inconvenience. Patients undergoing such a process are initiated on heparin while their INRs drift to normal levels. Immediately prior to surgery, heparin is discontinued and restarted several hours after the procedure. Unfortunately, this process has resulted in a high incidence of surgical wound hematomas and other bleeding complications often requiring longer periods of discontinued anticoagulation or repeat surgical exploration. Previous investigators have tried to reduce the incidence of wound hematomas by prolonging the time from surgical wound closure to the reinitiation of heparin. A small randomized trial demonstrated that there was no significant difference in the incidence of wound hematomas whether heparin was started 6 hours or 24 hours after surgery (J Am Coll Cardiology 2000;35:1915-8). This has led many investigators to perform pacemaker and ICD implantation without reversal of warfarin therapy. A recent retrospective observational study demonstrated that the incidence of wound hematomas in patients with an INR of 2.6 was no different than patients with an INR of 1.5 (PACE 2004;27:358-60). Furthermore, a more recent, larger retrospective observational study reported in abstract form at the recent Heart Rhythm Society Annual 2007 Scientific Meeting demonstrated that not only is performing pacemaker and ICD implantations safe without reversing warfarin anticoagulation, but the incidence of wound hematomas is significantly smaller as compared to the strategy of reversing warfarin and initiating periprocedural heparin. Given these findings, the hypothesis of this randomized study is that pacemaker and ICD implantation while fully anticoagulated on warfarin therapy is safe. Findings from this study will have significant implications on the clinical practice of pacemaker or ICD implantation in this patient population given that no randomized study on this subject has been performed to date.

NCT ID: NCT00711893 Completed - Heart Failure Clinical Trials

Feature Assessment Study for Indications Based Programming

FASt-IBP
Start date: June 2008
Phase: N/A
Study type: Observational

The purpose of this evaluation is to assess the acceptance level of specific programming recommendations based on the patient's clinical needs and primary indications when using the feature 'Indications Based Programming' (IBP) available in the ZOOMVIEW Software Application for the TELIGEN DR / VR and COGNIS family of devices compared to daily life programming chosen by physicians.

NCT ID: NCT00709384 Completed - Atrial Flutter Clinical Trials

Prevention of Atrial Tachycardia After a Right Atriotomy II

Start date: January 2006
Phase: Phase 2
Study type: Interventional

The investigators performed a prophylactic peroperative linear lesions connecting the tricuspid annulus with a right atriotomy and the atriotomy with the inferior caval vein to prevent atrial flutter on 15 consecutive adult patients undergoing surgery for congenital heart disease. Conduction time between electrodes placed on both sides of the lesions is measured on the second postoperative day. Coronary angiography and electrophysiology study using an electroanatomic mapping system to assess conduction across the line are performed three month after the operation.