Clinical Trials Logo

Clinical Trial Details — Status: Enrolling by invitation

Administrative data

NCT number NCT04241692
Other study ID # Pro00013642
Secondary ID
Status Enrolling by invitation
Phase N/A
First received
Last updated
Start date November 19, 2020
Est. completion date March 1, 2023

Study information

Verified date July 2022
Source Children's National Research Institute
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study will be a comparison of two externally worn recording systems for documentation of cardiac arrhythmias in symptomatic patients or patients at risk for arrhythmia. Non-invasive documentation of cardiac arrhythmias can be done using the standard electrocardiogram (ECG). This has limitations given it is performed for only a 10 sec period. Alternative methods for making longer term recording have been developed. The standard device is the 24 hour 7-lead Holter monitor. Newer technology has simplified the hardware needed to make these longer term recordings, and incorporate a self-contained recording system in a patch that is applied over the patient's chest. Little is known comparing the sensitivity, specificity and recording noise / signal artifact between the older technology (standard 24-Hour Holter monitor) and the Patch electrode.


Description:

Objective: Comparison of two externally worn recording systems for documentation of cardiac arrhythmias in symptomatic patients or patients at risk for arrhythmia. Non-invasive documentation of cardiac arrhythmias can be done by attempting to take a snapshot view of a patient's cardiac rhythm using the standard electrocardiogram (ECG). This has limitations given it is performed for only a 10 sec period, and requires the patient to be symptomatic at the time of the recording. Therefore, the sensitivity of this technique is very low. Alternative methods for making longer term recording have been developed and used for decades. The standard device is the 24 hour 7-lead Holter monitor. These devises are large, restrict patient mobility and require cables to be connected between the applied skin ECG electrodes placed on the patient's chest and the recording device. Newer technology has simplified the hardware needed to make these longer term recordings, and incorporate a self-contained recording system in a patch that is applied over the patient's chest. These units allow for unlimited mobility, are significantly smaller, easier to wear and have eliminated the requirement for cables to connect the electrodes with the recording device. However, little is known comparing the sensitivity, specificity and recording noise / signal artifact between the older technology (standard 24-Hour Holter monitor) and the Patch electrode. Specific Aims: Aim 1: Comparison of Cardiac Arrhythmia Documentation between Standard 24-Hour Holter Monitor vs. Patch Monitor To evaluate the diagnostic yield for cardiac arrhythmias between the two recording systems. The presence and frequency (qualitative and quantitative) of cardiac arrhythmias documented by each recording system with be compared. To allow for this type of comparison, each enrolled research subject with wear both systems simultaneously. Aim 2: Comparison of Recording Quality between Standard 24-Hour Holter Monitor vs. Patch Monitor To evaluate percentage of time ECG signal quality is poor and uninterpretable. Aim 3: Comparison of Comfortability Between Standard 24-HourHolter Monitor vs. Patch Monitor Recording Quality To evaluate level of patient's discomfort during the application of each recording system. Since both systems will be applied at the same time it may be hard for the research subject to rank the comfortability of the two systems. We will focus in this aim at more objective measures such as skin irritation under the recording electrodes, and frequency of time during which the skin electrodes come off the patient and require re-application. Hypotheses: Aim 1: Comparison of Cardiac Arrhythmia Documentation between Standard 24-Hour Holter Monitor vs. Patch Monitor We hypothesize that there will be no qualitative or quantitative difference in arrhythmia frequency between the two recording techniques, i.e. that both devices will detect all spontaneous arrhythmias with similar quantitative counts of ectopic beats (+/- 5%). Aim 2: Comparison of Recording Quality between Standard 24-Hour Holter Monitor vs. Patch Monitor We hypothesize that recording quality will be better with the Patch Monitor since there are not 7 separately applied skin electrodes and cables connecting the electrodes with the recorder, resulting in a lower percent of poor ECG signal quality. Aim 3: Comparison of Comfortability Between Standard 24-hour Holter Monitor vs. Patch Monitor Recording Quality We hypothesize that the degree of skin irritation and level of discomfort in the region of application will be less with the Patch Monitor. We hypothesize that the ECG leads will fall off from its site of application will be less with the Patch Monitor.


Recruitment information / eligibility

Status Enrolling by invitation
Enrollment 50
Est. completion date March 1, 2023
Est. primary completion date February 1, 2023
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group N/A to 35 Years
Eligibility Inclusion Criteria: - Any infant, child, adolescent, or young adult with one or more of the following: 1. Syncope 2. Pre-syncope 3. Palpitations 4. Management of a known or suspected cardiac arrhythmia Exclusion Criteria: - Any inflamed or friable skin over the anterior thorax and upper abdomen or a sternal incision within 3 months from the date of enrollment

Study Design


Related Conditions & MeSH terms


Intervention

Device:
CarnationTM Ambulatory Monitoring Sternal ECG Patch System
A newly developed cardiac rhythm monitoring system
Conventional 24-Hour 7 Lead Holter Monitor Recorder
Traditional recordings made using a standard 24-hour Holter monitor.

Locations

Country Name City State
United States Children's National Hospital Washington District of Columbia

Sponsors (1)

Lead Sponsor Collaborator
Children's National Research Institute

Country where clinical trial is conducted

United States, 

References & Publications (7)

Bigger JT Jr, Reiffel JA, Coromilas J. Ambulatory electrocardiography. In: Platia E, ed. Non-Pharmacologic Management of Cardiac Arrhythmias. Philadelphia: JB Lippincott, 1986:36-61.

Clark PI, Glasser SP, Spoto E Jr. Arrhythmias detected by ambulatory monitoring. Lack of correlation with symptoms of dizziness and syncope. Chest. 1980 Jun;77(6):722-5. — View Citation

Gibson TC, Heitzman MR. Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope. Am J Cardiol. 1984 Apr 1;53(8):1013-7. — View Citation

Heilbron EL. Advances in modern electrocardiographic equipment for long-term ambulatory monitoring. Card Electrophysiol Rev. 2002 Sep;6(3):185-9. Review. — View Citation

Jonas S, Klein I, Dimant J. Importance of Holter monitoring in patients with periodic cerebral symptoms. Ann Neurol. 1977 May;1(5):470-4. — View Citation

Kapoor WN, Cha R, Peterson JR, Wieand HS, Karpf M. Prolonged electrocardiographic monitoring in patients with syncope. Importance of frequent or repetitive ventricular ectopy. Am J Med. 1987 Jan;82(1):20-8. — View Citation

Zimetbaum P, Josephson ME. Evaluation of patients with palpitations. N Engl J Med. 1998 May 7;338(19):1369-73. Review. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Difference in Cardiac Arrhythmia Detection Between Recording Systems The presence (yes/no) and frequency of cardiac arrhythmias will be quantitated on each recording system for comparison 24 Hours
Primary Difference in Signal Quality Between Recording Systems We will quantitatively evaluate percentage of time signal quality is poor and uninterpretable with each recording system. 24 Hours
Secondary Difference in Skin Discomfort Between Recording Systems User will rate skin discomfort on a pre-determined scale: none, mild, moderate, severe at each site of application 24 Hours
See also
  Status Clinical Trial Phase
Completed NCT06038708 - Head-up Tilt Test in Patients With Reflex Syncope and Asystolic Response Who Received a Dual-chamber Pacemaker With the Closed Loop Stimulation (CLS) and Participated in the BIOSync Trial
Completed NCT00069693 - Evaluation of Chronic Orthostatic Intolerance N/A
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Completed NCT02565238 - BIO.MASTER.BioMonitor 2 Study N/A
Active, not recruiting NCT01965899 - Usability Study to Assess the Reveal LINQ Insertable Cardiac Monitor System N/A
Completed NCT00746564 - Study of New Implantable Loop Recorder N/A
Completed NCT00359203 - ISSUE3: International Study on Syncope of Uncertain Etiology 3 Phase 4
Recruiting NCT04972071 - SW-RCT Implementation of Canadian Syncope Risk Score Based Practice Recommendations N/A
Completed NCT04198220 - BIO|STREAM.ICM Obesity
Recruiting NCT04533425 - Practical Approaches to Care in Emergency Syncope
Completed NCT05571254 - The Management of Transient Loss of Consciousness and Suspected Syncope in European Emergency Departments
Recruiting NCT05621460 - The Effect of Water Carbonation on Orthostatic Tolerance N/A
Not yet recruiting NCT05957315 - Mobile Cardiac Outpatient Telemetry for Unexplained Syncope N/A
Recruiting NCT04615065 - Acutelines: a Large Data-/Biobank of Acute and Emergency Medicine
Completed NCT05729724 - Effect of Pharmacological Interventions on Systolic Blood Pressure Drops (SynABPM 2 Proof-of-concept)
Completed NCT05782712 - Rapid Measurement of Adenosine in Syncope Patients
Completed NCT03786640 - Abbott Brady 3T MRI PMCF
Recruiting NCT03803969 - ConfirmRxTM: Posture and Activity N/A
Recruiting NCT05575934 - Management of Transitory Loss of Consciousness and Syncopes in the Emergency Department
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)