Clinical Trials Logo

Clinical Trial Summary

This study seeks to provide evidence that use of Philips mobile cardiac outpatient telemetry (MCOT) devices may improve patient care for patients who present to emergency departments (EDs) with syncope, which is a temporary loss of consciousness also known as fainting or who present experiencing a near temporary loss of consciousness (near syncope). It is set up as a random controlled trial, which means research participants will be randomly assigned to receiving the device or usual care. Patients 50 years or older who come to the ED of Carilion Roanoke Memorial Hospital will be screened by study team members for unexplained syncope or near syncope across three ED dispositions: hospital admission, emergency department clinical decision unit admission (ED CDU) and emergency department. After consent, subjects will be enrolled and randomized, via REDCap randomization, in the study. At the time of subject discharge the MCOT device will be placed on the chest for the arm of intervention patients (for subjects who were admitted, the research study team will follow the patient's clinical course and placement of the device will occur at discharge); subjects will also receive brief instruction on the care and maintenance of the device and a patient education guide. The research team will contact the subjects for a telephone follow up at 14 and 30 days post-enrollment. The study will establish the efficacy of mobile cardiac outpatient telemetry in comparison to observation telemetry. Research objectives are to 1) Measure the time to medical intervention in patients with unexplained syncope or near syncope fitted with a Philips MCOT at the time of hospital discharge compared to patients treated with usual care for unexplained syncope or near syncope; and 2) Measure the time to arrhythmia diagnosis in patients with unexplained syncope or near syncope fitted with a Philips MCOT at the time of hospital discharge compared to patients treated with usual care for unexplained syncope or near syncope.


Clinical Trial Description

The study will establish the efficacy of ED-based, post-discharge mobile cardiac outpatient telemetry for patients discharged with a diagnosis of unexplained syncope. Research objectives are to 1) Measure the time to medical intervention in patients with unexplained syncope fitted with a Philips MCOT at the time of hospital discharge compared to patients treated with usual care for unexplained syncope; and 2) Measure the time to arrhythmia diagnosis in patients with unexplained syncope fitted with a Philips MCOT at the time of hospital discharge compared to patients treated with usual care for unexplained syncope. The hypothesis for this study is that participants who receive the Philips MCOT device upon discharge will experience a shorter time to diagnosis for the cause of their episode of syncope and receive subsequent medical intervention sooner than those who do not receive an MCOT device. Medical intervention is defined as a change in medical management, escalation of diagnostic testing or device, or medical procedure that might result from diagnostic information obtained from outpatient cardiac monitoring following a syncopal episode. Change in medical management includes, but is not limited to, initiation of a new medication, lifestyle modification recommendations, referral to medical specialist such as cardiology or electrophysiology. Escalation of diagnostic device may include, but is not limited to, ordering of diagnostic studies such as a cardiac stress test, echocardiogram, other cardiac testing at the preference of the treating subspecialist, or placement of a longer duration cardiac monitor such as an implantable loop recorder or cardiac event monitor. Medical procedure is defined as cardiac pacemaker implantation, cardiac heart catheterization, or other invasive cardiac procedure felt to be medically necessary by the treating specialist or subspecialist physician. An arrhythmia is an abnormal heart rhythm. In some instances syncope/near syncope, or fainting/near fainting, may be the result of an undiagnosed abnormal heart rhythm. Abnormal heart rhythms that might result in a fainting include atrial fibrillation, supraventricular tachycardia, sinus pause, Mobitz Type II heart block, complete heart block, and ventricular tachycardia. Wearing the mobile cardiac outpatient telemetry monitor increases the likelihood of identifying fainting episodes that were caused by abnormal heart rhythms. Previous studies are variable in the number and type of arrythmias captured that would mandate medical intervention of some type that is measurable (medication, ablation, etc). All comer diagnosis and absolute diagnosis of any arrythmia is much higher than 10%. Thus, we based the pilot study size based on the lowest reported incidence in the literature for arrythmias requiring a change in a patient's medical care of 10% as the lowest suspected incidence for the Na sample size calculation. With a one-sided means test, 1-b at 0.80, and a of 0.05, 8 events in Na requiring medical intervention of some type would be required to demonstrate a 7d difference in time to intervention from the usual care group or 80 patients in the Na and 160 total. The device manufacturer is providing up to 120 devices with monitoring (up to 240 total study enrollees), which will allow for flexibility in the event of loss to follow up or to increase power. Study participants will be randomized at ED discharge into either the control group, which receives usual care (referrals to follow up with outpatient services), or the experimental group, which receives usual care AND are fitted with a Philips MCOT device and remotely monitored for 30 days along with possible referrals to follow up with outpatient services. Data will be collected from participants' medical records to determine whether additional episodes of syncope or near syncope, diagnosis, and/or treatment occurred. Additionally, participants will be contacted by the study team at 14 and 30 days post-discharge to answer questions to determine whether additional episodes of syncope or near syncope occurred, whether treatment occurred, and whether they complied with follow up referrals. To determine if there is a difference in the time to medical intervention and in time to arrhythmia diagnosis, we will conduct two-sample tests of proportions. Secondary outcome analysis will be descriptive. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05957315
Study type Interventional
Source Carilion Clinic
Contact Andrew B Moore, MD
Phone 540-981-7000
Email abmoore1@carilionclinic.org
Status Not yet recruiting
Phase N/A
Start date September 1, 2023
Completion date October 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05048602 - Drug-induced Brugada Syndrome Research Database
Completed NCT05053243 - Clinical Validation of the AliveCor Kardia 12L and 6L Devices N/A
Completed NCT01913561 - The Use of Master Caution Garment for Continuous Monitoring for Arrhythmia Detection N/A
Completed NCT01688648 - Comparison Between Lidocaine, Dexmedetomidine, and Their Combined Infusion in Subjects Undergoing Coronary Artery Bypass Graft N/A
Completed NCT01396226 - A Multi-centre Study Comparing the Effects of AZD2927 and Placebo on the Electrical Activity in the Heart in Patients Phase 2
Completed NCT00756886 - Does Atorvastatin Prevent Post Operative Atrial Fibrillation After Pulmonary Resection: A Randomized Clinical Study N/A
Terminated NCT00624520 - Mental Stress Reduction in Defibrillator Patients Phase 3
Terminated NCT00721149 - NAVISTAR® THERMOCOOL® Catheter for the Radiofrequency Ablation of Symptomatic Paroxysmal Atrial Fibrillation- Treatment Use Study Phase 3
Completed NCT00510029 - Single Ascending Dose Study of the Safety, Tolerability, and Pharmacokinetics of GAP-134 Administered Intravenously Phase 1
Completed NCT00578617 - Ablation vs Drug Therapy for Atrial Fibrillation - Pilot Trial N/A
Active, not recruiting NCT00135174 - Cost-Effectiveness of Routine Follow-up Visits in Patients With a Pacemaker: The Followpace Study N/A
Completed NCT00119847 - Electrophysiological Effects of Late PCI After MI N/A
Completed NCT00035490 - Efficacy and Safety Evaluation of Azimilide Dihydrochloride in Patients With Implantable Cardioverter Defibrillators Phase 3
Completed NCT00023556 - Genetic Architecture of Heart Disease in Rural Brazil N/A
Completed NCT01076361 - Model 4968 CAPTURE EPI® STERIOD-ELUTING BIPOLAR EPICARDIAL PACING LEAD Post-approval Study N/A
Completed NCT00004560 - Public Access Defibrillation (PAD) Community Trial Phase 3
Recruiting NCT00138931 - Genetics of Cardiovascular and Neuromuscular Disease
Completed NCT00622453 - Arrhythmias in Myotonic Muscular Dystrophy N/A
Completed NCT01076348 - Model 4965 Post-Approval Study
Completed NCT00000531 - Antiarrhythmics Versus Implantable Defibrillators (AVID) Phase 3