Clinical Trial Summary

This research aims to integrate and develop a novel Brain-Computer Interface (BCI) controlled soft robotic glove, evaluate the ability of the glove in achieving common hand grasping postures and to assess the efficacy of the glove in assisting stroke patients with completing functional tasks. The BCI-controlled soft robotic glove utilizes patients' user intent to deliver specific electroencephalographic patterns that can trigger robot-assisted hand movement to the affected hand.


Description:

Hand motor impairment is very common after a stroke. These impairments include difficulty moving and coordinating the hands and fingers, which inhibits stroke patients from being able to perform daily functional tasks independently, resulting in a reduced quality of life. More than half of people with upper limb impairment after stroke will still have problems many months to years after their stroke. Therefore, improving hand function is a core element of rehabilitation. Many possible interventions have been developed; these may involve different exercises or training, specialist equipment or techniques, or they could take the form of a drug (pill or injection) given to help hand movement. There is limited evidence that suggests the following interventions may be effective: constraint-induced movement therapy, mental practice, mirror therapy,interventions for sensory impairment, virtual reality and a relatively high dose of repetitive task practice. Current hand rehabilitation robotic devices are typically driven by rigid linkages or joints, which subject the patient's fingers into a single plane of motion that will feel unnatural and uncomfortable. On top of that,these devices belong to the class of continuous passive motion (CPM) devices that only promote hand range-of-motion, but do not require the patient to play a semi-active role in performing the hand exercises. Furthermore, there is a huge demand for solutions assisting stroke patients with using the densely paralyzed hand to perform activities of daily living (ADL) in real life, which is not available at present. Most of the hand rehabilitation robotic devices available in the market cannot assist paralyzed hand to carry out ADL. To develop an assistive device to solve this unmet need, we decided to combine BCI technology with the wearable soft robotic glove, which enables actuation of paralyzed hand by motor imagery.


Recruitment information / eligibility

Status Completed
Enrollment 11
Est. completion date April 22, 2019
Est. primary completion date April 22, 2019
Accepts healthy volunteers No
Gender All
Age group 55 Years to 90 Years
Eligibility Inclusion Criteria:

- Aged 55-90 years regardless of lesion size, race

- History of stroke less than 3 months prior to participation

- Stroke type: ischemic or haemorrhagic

- Fugl-Meyer motor score (FM score) of upper extremity impairment of 0-45 out of a maximum score of 66 on the Fugl-Meyer assessment scale

- Ability to pay attention and maintain supported sitting for 1.5 hours continuously

- Lack of or poor hand mobility (Medical Research Council Grade = 2/5)

- Able to give own consent

- Able to comprehend and follow commands (Abbreviated Mental Test equal or more than 7)

- Fulfil BCI resting brain states on initial screening.

- Unilateral upper limb impairment

Exclusion Criteria:

- Recurrent clinical stroke

- Functional status: severe aphasia or inattention, unstable medical conditions which may affect participation (e.g. unresolved sepsis, postural hypotension) or anticipated life expectancy of <1 year due to malignancy or neurodegenerative disorder)

- Hemispatial neglect (visual or sensory) or severe visual impairment despite visual aids

- History of severe depression or active psychiatric disorder

- Skull defect or previous cranial surgery as this would affect physical fit of EEG cap interface

- Local arm factors: severe spasticity Modified Ashworth scale >1+ in any region, fixed joint contractures or joint replacements, patients with poor skin conditions which would contraindicate repetitive arm training, upper limb pain impeding movements with visual analogue scale (VAS score) >4/10, other conditions ensuing upper limb weakness, skull defect, polydactyly or amputation of fingers, and allergy to electrodes or adhesive gel

Study Design


Related Conditions & MeSH terms


Intervention

Device:
BCI Robot Assisted Hand Therapy
18 sessions (3 times per week for a total of 6 weeks) of 1.5 hours each training (60 minutes of BCI Robot and 30 minutes of the standard hand therapy). Session 1-3. Peg game: Lateral movement of gears/cups Session 4-6. Moving cups onto a shelf: Elevation process for the arm, small cups to be used. Session 7-9. Carrying of basket: Heavier load to be used, patient to hold the basket by the handles at the side, not by its base. Session 10-12. Opening bottle + pouring into a cup: Training of ADL Session 13-15. Eating: Use of a modified spoon to train ADL Session 16-18. Box and blocks: Precise index finger and thumb control
CPM Robot Assisted Hand Therapy
18 sessions (3 times per week for a total of 6 weeks) of 1.5 hours each training (60 minutes of Passive Robot and 30 minutes of the standard hand therapy).The procedure will include the following: Session 1-18: Continuous passive motion

Locations

Country Name City State
Singapore National University Hospital Singapore

Sponsors (3)

Lead Sponsor Collaborator
National University Hospital, Singapore Agency for Science, Technology and Research, National University, Singapore

Country where clinical trial is conducted

Singapore, 

References & Publications (15)

Ang KK, Chin ZY, Wang C, Guan C, Zhang H. Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b. Front Neurosci. 2012 Mar 29;6:39. doi: 10.3389/fnins.2012.00039. eCollection 2012. — View Citation

Ang KK, Chua KS, Phua KS, Wang C, Chin ZY, Kuah CW, Low W, Guan C. A Randomized Controlled Trial of EEG-Based Motor Imagery Brain-Computer Interface Robotic Rehabilitation for Stroke. Clin EEG Neurosci. 2015 Oct;46(4):310-20. doi: 10.1177/1550059414522229. Epub 2014 Apr 21. — View Citation

Ang KK, Guan C, Phua KS, Wang C, Zhao L, Teo WP, Chen C, Ng YS, Chew E. Facilitating effects of transcranial direct current stimulation on motor imagery brain-computer interface with robotic feedback for stroke rehabilitation. Arch Phys Med Rehabil. 2015 Mar;96(3 Suppl):S79-87. doi: 10.1016/j.apmr.2014.08.008. — View Citation

Ang KK, Guan C, Phua KS, Wang C, Zhou L, Tang KY, Ephraim Joseph GJ, Kuah CW, Chua KS. Brain-computer interface-based robotic end effector system for wrist and hand rehabilitation: results of a three-armed randomized controlled trial for chronic stroke. Front Neuroeng. 2014 Jul 29;7:30. doi: 10.3389/fneng.2014.00030. eCollection 2014. — View Citation

C.H. Yeow, A.T. Baisch, S.G. Talbot, C.J. Walsh. Differential spring stiffness design for finger therapy exercise device: bio-inspired from stiff pathological finger joints. ASME Journal of Medical Devices 2012

F.Z. Low, H.K. Yap, J.H. Lim, F. Nasrallah, J.C.H. Goh, C.H. Yeow. Wearable Soft Robotics for Rehabilitation. 8th Asian Pacific Conference on Biomechanics 2015 (Sapporo).

H.K. Yap, F. Nasrahllah, J.H. Lim, F.Z. Low, J.C.H. Goh, C.H. Yeow. MRC-Glove: A fMRI Compatible Soft Robotic Glove for Hand Rehabilitation Application, 14th IEEE/RAS-EMBS International Conference on Rehabilitation Robotics (ICORR 2015).

H.K. Yap, J.C.H. Goh, C.H. Yeow. Design and Characterization of Soft Actuator for Hand Rehabilitation Application. 6th European Conference of the International Federation for Medical and Biological Engineering (MBEC 2014)

H.K. Yap, J.H. Lim, F. Nasrahllah, J.C.H. Goh, C.H. Yeow. A Soft Exoskeleton for Hand Assistive and Rehabilitation Application Page 8 using Pneumatic Actuators with Variable Stiffness, in IEEE Int. Conf. Robotics and Automation 2015.

H.K. Yap, J.H. Lim, F. Nasrallah, J.C.H. Goh, C.H. Yeow. Customizable Pneumatic Bending Actuator for Finger Rehabilitation. Design of Medical Devices Conference Europe 2014 (Delft)

Hong Kai Yap, Kamaldin N, Jeong Hoon Lim, Nasrallah FA, Goh JCH, Chen-Hua Yeow. A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging. IEEE Trans Neural Syst Rehabil Eng. 2017 Jun;25(6):782-793. doi: 10.1109 — View Citation

Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, de Ferranti S, Després JP, Fullerton HJ, Howard VJ, Huffman MD, Judd SE, Kissela BM, Lackland DT, Lichtman JH, Lisabeth LD, Liu S, Mackey RH, Matchar DB, McGuire DK, Mohler ER 3rd, Moy CS, Muntner P, Mussolino ME, Nasir K, Neumar RW, Nichol G, Palaniappan L, Pandey DK, Reeves MJ, Rodriguez CJ, Sorlie PD, Stein J, Towfighi A, Turan TN, Virani SS, Willey JZ, Woo D, Yeh RW, Turner MB; American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Heart disease and stroke statistics--2015 update: a report from the American Heart Association. Circulation. 2015 Jan 27;131(4):e29-322. doi: 10.1161/CIR.0000000000000152. Epub 2014 Dec 17. Erratum in: Circulation. 2016 Feb 23;133(8):e417. Circulation. 2015 Jun 16;131(24):e535. — View Citation

Rojas JI, Zurrú MC, Romano M, Patrucco L, Cristiano E. Acute ischemic stroke and transient ischemic attack in the very old--risk factor profile and stroke subtype between patients older than 80 years and patients aged less than 80 years. Eur J Neurol. 2007 Aug;14(8):895-9. — View Citation

Rosamond W, Flegal K, Furie K, Go A, Greenlund K, Haase N, Hailpern SM, Ho M, Howard V, Kissela B, Kittner S, Lloyd-Jones D, McDermott M, Meigs J, Moy C, Nichol G, O'Donnell C, Roger V, Sorlie P, Steinberger J, Thom T, Wilson M, Hong Y; American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Circulation. 2008 Jan 29;117(4):e25-146. Epub 2007 Dec 17. Erratum in: Circulation. 2010 Jul 6;122(1):e10. Kissela, Bret [corrected to Kissela, Brett]. — View Citation

Venketasubramanian N, Chen CL. Burden of stroke in Singapore. Int J Stroke. 2008 Feb;3(1):51-4. doi: 10.1111/j.1747-4949.2008.00181.x. — View Citation

* Note: There are 15 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Action Research Arm Test It assesses a client's ability to handle objects differing in size, weight and shape and therefore can be considered to be an arm-specific measure of activity limitation 30 minutes
Primary Fugl-Meyer Assessment It is designed to assess motor functioning, balance, sensation and joint functioning. 20 minutes
Primary Grip Strength Test The purpose of this test is to measure the maximum isometric strength of the hand and forearm muscles. 5 minutes
See also
  Status Clinical Trial Phase
Recruiting NCT04043052 - Mobile Technologies and Post-stroke Depression N/A
Recruiting NCT03869138 - Alternative Therapies for Improving Physical Function in Individuals With Stroke N/A
Completed NCT04101695 - Hemodynamic Response of Anodal Transcranial Direct Current Stimulation Over the Cerebellar Hemisphere in Healthy Subjects N/A
Completed NCT04034069 - Effects of Priming Intermittent Theta Burst Stimulation on Upper Limb Motor Recovery After Stroke: A Randomized Controlled Trial N/A
Terminated NCT03052712 - Validation and Standardization of a Battery Evaluation of the Socio-emotional Functions in Various Neurological Pathologies N/A
Completed NCT00391378 - Cerebral Lesions and Outcome After Cardiac Surgery (CLOCS) N/A
Recruiting NCT06204744 - Home-based Arm and Hand Exercise Program for Stroke: A Multisite Trial N/A
Active, not recruiting NCT06043167 - Clinimetric Application of FOUR Scale as in Treatment and Rehabilitation of Patients With Acute Cerebral Injury
Active, not recruiting NCT04535479 - Dry Needling for Spasticity in Stroke N/A
Completed NCT03985761 - Utilizing Gaming Mechanics to Optimize Telerehabilitation Adherence in Persons With Stroke N/A
Recruiting NCT00859885 - International PFO Consortium N/A
Recruiting NCT06034119 - Effects of Voluntary Adjustments During Walking in Participants Post-stroke N/A
Completed NCT03622411 - Tablet-based Aphasia Therapy in the Chronic Phase N/A
Completed NCT01662960 - Visual Feedback Therapy for Treating Individuals With Hemiparesis Following Stroke N/A
Recruiting NCT05854485 - Robot-Aided Assessment and Rehabilitation of Upper Extremity Function After Stroke N/A
Active, not recruiting NCT05520528 - Impact of Group Participation on Adults With Aphasia N/A
Completed NCT03366129 - Blood-Brain Barrier Disruption in People With White Matter Hyperintensities Who Have Had a Stroke
Completed NCT03281590 - Stroke and Cerebrovascular Diseases Registry
Completed NCT05805748 - Serious Game Therapy in Neglect Patients N/A
Recruiting NCT05993221 - Deconstructing Post Stroke Hemiparesis