Cataract Clinical Trial
Official title:
Evaluation of the Impact of Light Intensity and Light Temperature on the Efficacy of Presbyopic Corrections With Bilateral Implantation of Multifocal Intraocular Lenses in a Series of Activities of Daily Living
Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 activities of daily living (ADLs) that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal intraocular lenses (IOLs) implantation, and to compare their capacity to perform ADLs (ADL scores) between three study groups (SG): SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs
Patients who underwent presbyopic correction with bilateral implantation of multifocal IOLs are supposed to have sufficient uncorrected vision capacity for ADLs that require near (ie. book reading) or intermediate (ie. reading in a computer screen) vision acuity. However, it is known that light intensity and light temperature has a great impact on near/intermediate vision capacity, but also patients that have been implanted with multifocal IOLs are most likely to present completely different lighting needs than patients with their own crystalline lenses. Primary objective of this study is to identify the optimal task lighting conditions (in terms of light intensity and light temperature) for 10 ADLs that require near or intermediate vision acuity in a validated ADL simulation framework for a sample of patients who underwent presbyopic correction with bilateral multifocal IOLs implantation, and to compare their capacity to perform the ADLs (ADL scores) in 9 different lighting combinations (combinations of light intensity and light temperature) between three study groups: SG1. patients implanted bilaterally with trifocal diffractive IOLs, SG2. patients implanted bilaterally with bifocal hybrid (diffractive-refractive) IOLs, SG3. patients implanted bilaterally with monofocal IOLs The study is conducted in an experimental facility in a hospital room with a dimension of 6.87 × 2.9 × 3 m (depth × width × height) and flat white surface walls (reflectance: 70%). Αn advanced light diffusion system has been installed, which consists of four linear LED luminaires producing low glare (unified glare rating (UGR) < 19). Light intensity (dimming / in foot candles - fc) and light temperature (white tuning / (in Kelvins - K) have been adjusted using the Casambi wireless control application (Casambi Technologies Oy Inc., Espoo, Finland), which uses integrated Bluetooth mesh technology and secures maximal uniformity at different user-defined lighting settings. The four LED luminaires have been mounted on the ceiling. The exact luminaire positioning and the amount of the provided luminous flux have been defined using the RELUX light simulation tool (version 2021.1.1.0) (Relux Informatik AG, Münchenstein, Switzerland) prior to the installation. The confirmation of illuminance and on-site adjustments have been confirmed with the Extech Lux Meter EA30 (Extech Instruments Corporation, Nashua, NH, United States). As regards photometric properties derived from lighting laboratory photometric measurements, the correlated color temperature (CCT) of the luminaires ranges between 2700 K and 6500 K, emitting a maximum luminous flux of 10,626 lm and 11,508 lm, respectively. The exact radiant flux P(λ) emitted from the selected light sources has been measured using a Konica Minolta CL-500A spectrum meter for the wavelength range of 380-780 nm using a step of 1 nm. The power of each luminaire is 106 W, resulting in luminous efficacy of 100.2 lm/W and 108.6 lm/W for 2700 K and 6500 K, respectively. The color rendering index (CRI) is 84. The wireless dimming control system enables dimming from 0% to 100% and vice versa. The 9 lighting combinations (light intensity, light temperature) are the following: 3000 K - 25 fc, 3000 K - 50 fc, 3000 K - 75 fc / 4000 K - 25 fc, 4000 K - 50 fc, 4000 K - 75 fc / 6000 K - 25 fc, 6000 K - 50 fc, 6000 K - 75 fc In specific, patients address the following ten ADLs: 1. Phone Book Search (PBS), 2. Supermarket receipt (SupRe), 3. Book reading (BR), 4. Cellular message (CM), 5. Cellular entry search (CES), 6. Reading computer screen (RCS), 7. Drops bottle reading (DR), 8. Subtitles reading (SubRe), 9. Open door test (ODT), and, 10. Screwdriver test (ST). Test-retest reliability will be assessed by calculating intraclass correlation coefficients (ICCs) for all ADLs at the nine combinations of light conditions in two different visits with an average 15-day time window to prevent memory effect. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |