Clinical Trials Logo

Clinical Trial Summary

The Hanita CleaRing device is an intraocular implant designed for inhibition of PCO leading to reduction in the Nd:YAG treatment rate. The device is implanted into the capsular bag after the extraction of the crystalline lens and prior to implantation of the IOL. The device is manufactured by Hanita Lenses from a hydrophilic acrylic co-polymer which is being used for the production of Intra-ocular lenses.


Clinical Trial Description

Cataract surgery has undergone significant improvement in terms of surgical technique, instrumentation and the quality of intraocular lenses (IOLs) over the past decades. Although the rate of posterior capsular opacification (PCO) has decreased, it is still the most common complication following uneventful cataract surgery, with the rate of laser capsulotomy ranging from 10% to 37%1-5 ND:YAG capsulotomy is a highly successful treatment, but it is not free of complications, such as increased intraocular pressure (IOP), pitting or dislocation of the IOL, cystoid macular edema, and retinal detachment. PCO also places an economic burden on the healthcare system. The importance of PCO prevention has increased in recent years, due to the expanding popularity of premium IOLs. Patients implanted with a premium IOL usually have high demands with regard to outcome, and PCO can also have an earlier effect on the performance of a premium IOL (i.e., multifocal IOLs). Previous attempts to prevent PCO have included investigations of various IOL materials and designs, surgical techniques, and pharmacological materials. Unexpectedly lower PCO rates were recently noticed in eyes that were implanted with a special type of IOL, e.g., the Synchrony IOL (AMO, Santa Ana, CA, USA)8 and the FluidVision IOL (PowerVision, Belmont, CA, USA). It was hypothesized that the capsular bag stayed open due to the special design of these IOLs, and that this should reduce the PCO rate. Based upon this concept, a special open capsule ring was designed for intracapsular implantation in an attempt to maintain the capsular bag open and to reduce PCO rate. Safety and efficacy of the device was demonstrated through several animal studies. The tested devices were effective in reducing posterior capsule opacification and Soemmering's ring formation by 69% to 77% compared to control group. The Hanita CleaRing device is designed to be implanted in the capsular bag together with a standard posterior chamber IOL in a minimally invasive cataract surgery. The device is intended to reduce posterior capsular opacification leading to reduced Nd:YAG treatment rate. The raw material of the device is a hydrophilic co-polymer, considered to be biocompatible and practically inert to the eye tissue. The objective of this study is to evaluate the safety and the efficacy of CleaRing device in cataract patients. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06083025
Study type Interventional
Source Hanita Lenses
Contact Inbal Ratner
Phone 035028702
Email inbalr@wmc.gov.il
Status Recruiting
Phase N/A
Start date April 15, 2023
Completion date April 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Completed NCT03321253 - Changes of Macular Pigment and Parameters of Eyes After YAG Laser Treatment in Cases With Capsule Opacification N/A
Recruiting NCT03701139 - Posterior Capsulotomy in Cataract Complicated With Primary Posterior Capsule Opacification. N/A
Recruiting NCT05501535 - Refraction Changes After Using ND: YAG LASER In Treatment of Posterior Capsular Opacification In Pseudo Phakic Eye
Completed NCT03184428 - Posterior Capsule Opacification Following Cataract Surgery With Implantation of the MICS IOL L313
Recruiting NCT02445274 - Two Different Cataract Surgical Procedures to Prevent Posterior Capsule Opacification N/A
Completed NCT02968290 - Quantification of Posterior Capsule Opacification in Pediatric Cataract N/A
Completed NCT01936701 - Comparison of the Effect of Hydrophobic Acrylic and Silicone 3-piece IOLs on Posterior Capsule Opacification N/A
Completed NCT01786356 - Posterior Capsule Opacification and Frequency of Nd:YAG Treatment and of Two IOLs: Hoya iMics Y-60H vs. Bausch&Lomb MI60 (MIMI) N/A
Completed NCT03192826 - Brinzolamide/Brimonidine Combination vs Brimonidine 0.2% in the Prevention of IOP Rise After Nd-YAG Laser Capsulotomy Phase 4
Completed NCT00855491 - Posterior Capsule Opacification (PCO) With AcrySof Single-Piece IOL N/A
Completed NCT03831074 - Posterior Capsule Opacification and Optical Quality of Different Hydrophobic Acrylic Intraocular Lenses N/A
Completed NCT01734343 - Posterior Capsule Opacification Development With Two Different Intraocular Lenses N/A
Completed NCT01125345 - Posterior Capsule Opacification (PCO) With Single Piece Hydrophobic Versus Hydrophillic Intraocular Lens (IOL) Phase 4
Recruiting NCT03857685 - LEC Proliferation in Vivo and In-vitro
Active, not recruiting NCT03605160 - An Innovative Method Fluid-jet to to Remove Residual Lens Fibers N/A
Completed NCT04007965 - Novel Technique of Pneumatic Posterior Capsulorhexis for Treatment and Prevention of Posterior Capsular Opacification N/A
Recruiting NCT03857412 - Posterior Capsule Opacification After Lens Capsule Polishing N/A
Completed NCT02975895 - Outcome of Different IOLs in Patients With and Without Uveitis N/A
Completed NCT02491918 - Clinical Trial : Complications of in the Bag IOL Versus Optic Capture of IOL in Pediatric Cataract Surgery N/A