Posterior Capsule Opacification Clinical Trial
Official title:
Influence of CleaRing Open-capsule Device on Refractive Predictability in Cataract Patients (Part 2)
The Hanita CleaRing device is an intraocular implant designed for inhibition of PCO leading to reduction in the Nd:YAG treatment rate. The device is implanted into the capsular bag after the extraction of the crystalline lens and prior to implantation of the IOL. The device is manufactured by Hanita Lenses from a hydrophilic acrylic co-polymer which is being used for the production of Intra-ocular lenses.
Cataract surgery has undergone significant improvement in terms of surgical technique, instrumentation and the quality of intraocular lenses (IOLs) over the past decades. Although the rate of posterior capsular opacification (PCO) has decreased, it is still the most common complication following uneventful cataract surgery, with the rate of laser capsulotomy ranging from 10% to 37%1-5 ND:YAG capsulotomy is a highly successful treatment, but it is not free of complications, such as increased intraocular pressure (IOP), pitting or dislocation of the IOL, cystoid macular edema, and retinal detachment. PCO also places an economic burden on the healthcare system. The importance of PCO prevention has increased in recent years, due to the expanding popularity of premium IOLs. Patients implanted with a premium IOL usually have high demands with regard to outcome, and PCO can also have an earlier effect on the performance of a premium IOL (i.e., multifocal IOLs). Previous attempts to prevent PCO have included investigations of various IOL materials and designs, surgical techniques, and pharmacological materials. Unexpectedly lower PCO rates were recently noticed in eyes that were implanted with a special type of IOL, e.g., the Synchrony IOL (AMO, Santa Ana, CA, USA)8 and the FluidVision IOL (PowerVision, Belmont, CA, USA). It was hypothesized that the capsular bag stayed open due to the special design of these IOLs, and that this should reduce the PCO rate. Based upon this concept, a special open capsule ring was designed for intracapsular implantation in an attempt to maintain the capsular bag open and to reduce PCO rate. Safety and efficacy of the device was demonstrated through several animal studies. The tested devices were effective in reducing posterior capsule opacification and Soemmering's ring formation by 69% to 77% compared to control group. The Hanita CleaRing device is designed to be implanted in the capsular bag together with a standard posterior chamber IOL in a minimally invasive cataract surgery. The device is intended to reduce posterior capsular opacification leading to reduced Nd:YAG treatment rate. The raw material of the device is a hydrophilic co-polymer, considered to be biocompatible and practically inert to the eye tissue. The objective of this study is to evaluate the safety and the efficacy of CleaRing device in cataract patients. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Completed |
NCT03321253 -
Changes of Macular Pigment and Parameters of Eyes After YAG Laser Treatment in Cases With Capsule Opacification
|
N/A | |
Recruiting |
NCT03701139 -
Posterior Capsulotomy in Cataract Complicated With Primary Posterior Capsule Opacification.
|
N/A | |
Recruiting |
NCT05501535 -
Refraction Changes After Using ND: YAG LASER In Treatment of Posterior Capsular Opacification In Pseudo Phakic Eye
|
||
Completed |
NCT03184428 -
Posterior Capsule Opacification Following Cataract Surgery With Implantation of the MICS IOL L313
|
||
Recruiting |
NCT02445274 -
Two Different Cataract Surgical Procedures to Prevent Posterior Capsule Opacification
|
N/A | |
Completed |
NCT02968290 -
Quantification of Posterior Capsule Opacification in Pediatric Cataract
|
N/A | |
Completed |
NCT01936701 -
Comparison of the Effect of Hydrophobic Acrylic and Silicone 3-piece IOLs on Posterior Capsule Opacification
|
N/A | |
Completed |
NCT01786356 -
Posterior Capsule Opacification and Frequency of Nd:YAG Treatment and of Two IOLs: Hoya iMics Y-60H vs. Bausch&Lomb MI60 (MIMI)
|
N/A | |
Completed |
NCT03192826 -
Brinzolamide/Brimonidine Combination vs Brimonidine 0.2% in the Prevention of IOP Rise After Nd-YAG Laser Capsulotomy
|
Phase 4 | |
Completed |
NCT00855491 -
Posterior Capsule Opacification (PCO) With AcrySof Single-Piece IOL
|
N/A | |
Completed |
NCT03831074 -
Posterior Capsule Opacification and Optical Quality of Different Hydrophobic Acrylic Intraocular Lenses
|
N/A | |
Completed |
NCT01734343 -
Posterior Capsule Opacification Development With Two Different Intraocular Lenses
|
N/A | |
Completed |
NCT01125345 -
Posterior Capsule Opacification (PCO) With Single Piece Hydrophobic Versus Hydrophillic Intraocular Lens (IOL)
|
Phase 4 | |
Recruiting |
NCT03857685 -
LEC Proliferation in Vivo and In-vitro
|
||
Active, not recruiting |
NCT03605160 -
An Innovative Method Fluid-jet to to Remove Residual Lens Fibers
|
N/A | |
Completed |
NCT04007965 -
Novel Technique of Pneumatic Posterior Capsulorhexis for Treatment and Prevention of Posterior Capsular Opacification
|
N/A | |
Recruiting |
NCT03857412 -
Posterior Capsule Opacification After Lens Capsule Polishing
|
N/A | |
Completed |
NCT02975895 -
Outcome of Different IOLs in Patients With and Without Uveitis
|
N/A | |
Completed |
NCT02491918 -
Clinical Trial : Complications of in the Bag IOL Versus Optic Capture of IOL in Pediatric Cataract Surgery
|
N/A |