View clinical trials related to Pneumothorax.
Filter by:Background: The Pleura is a double-layered membrane that surrounds the lungs. Pathological processes that involve the Pleura are called "Pleural diseases". Among them are included Pneumothorax (Air the chest cavity), Pleural effusions, and tumor formation. Ultrasound imaging of the Pleura to detect and assess pleural diseases has been proven as an excellent diagnostic and safe option. Ultrasound test uses sound waves to characterize the structure and function of different organs in health and disease. The standard technique used to create two-dimensional ultrasound picture is called Delay and Sum (DAS). Signals are transmitted and received from a series of elements and allow a two dimensional picture to be created. Because a large number of sensors is required, creating a two dimensional picture creates a large and usually redundant data pool. This fact leads to a need for stronger processors and larger operating systems, Consumption of higher energy, and hence an ungainly, slow, and expensive system. Signal Acquisition Modeling and Processing Laboratory (SAMPLE) in Weizmann institute has developed a data processing system that allows narrowing down the number of elements needed to process the ultrasound signal, while creating an ultrasound picture of abdominal organs in a satisfying resolution. Sometimes even better than standard methods. Research goal: Improvement of diagnosis and characterization of pleural diseases by Ultrasound, using a novel algorithm that was developed in SAMPLE laboratory in Weizmann Institute. The aim is to create a faster, more reliable ultrasound imaging while minimizing sampling rate and data volume. Methods: Tested population: Women and/or men who were diagnosed with Pneumothorax or Plural effusion with other imaging modalities, and healthy volunteers as a control group, Up to 30 participants per each group (Total up to 90), in a 1:1:1 Ratio. Research type: An open-labeled study. Experimental design: Participants that will meet the required conditions will be summoned to an exam in our imaging institute or will be scanned bedside, using the Verasonics ultrasound system, which allows free access to ultrasound raw Channel data. The information acquired, as well as other imaging scans of the participant, will be coded and delivered anonymously to SAMPLE laboratory for analysis.
Endotracheal intubation is a life-saving intervention that few infants need after birth. Although an endotracheal tube is the most reliable way of providing positive-pressure breath, the critical factor that determines the maximal efficacy of positive-pressure ventilation is the optimal placement of the endotracheal tube tip. There are various methods available to determine the initial depth of endotracheal tube (ETT) that are based on the infant's birth weight, gestational age, anthropometric measurements, and others include vocal cord guide and suprasternal palpation methods. The Neonatal Resuscitation Program (NRP) textbook, in its 7th edition of the textbook, recommends a gestational age chart and nasal-tragus length method for estimating endotracheal tube insertion depth during cardiopulmonary resuscitation of the neonate. The evidence to support these two methods is, however, limited. Hence, we designed this study to determine the accuracy of two methods, gestational age chart and nasal-tragus length method, recommended by the Neonatal Resuscitation Program.
Out-of-hospital care during Chemical-Biological-Radiological-Nuclear-explosive (CBRNe) events have recently evolved, but the available knowledge is still extremely partial. In particular, the debate is still ongoing regarding which life-saving maneuvers should be implemented in the pre-decontamination phase while wearing CBRNe personal protective equipment (PPE). The investigators hypothesized that PPE may lengthen the execution times and worsen the success rate of invasive and non-invasive procedures. This trial involves residents in emergency medicine and anesthesia/critical care of the University of Padova (Italy) with the following procedures performed on high-fidelity manikins, after being divided into two groups (wearing and not wearing PPE): positioning of peripheral venous access; intraosseous access; drug preparation and administration; tension pneumothorax (PNX) needle decompression; tourniquet positioning; chest compressions. The primary outcome was the chest compressions depth mean difference between the two groups. As secondary outcomes, the investigators measured differences between the two groups in: the percentages of correct release during chest compressions; chest compressions rate (beats per minute); and the times needed to complete the above-mentioned procedures (other than chest compressions). The investigators expect that PPE will reduce CPR quality or delay the completion of the procedures.
The study will be carried out by the principal investigator and his team at the Division of Cardiovascular and Thoracic Surgery of the Department of Surgery, College of Medicine, University of Ibadan and the University College Hospital, Ibadan (UCH), which is the Teaching Hospital of the Medical College.The study sets out to prospectively compare the early and long-term outcomes between the use of purse-string (suturing U-technique) and Un-reapproximated thoracostomy wound edges (Occlusive adhesive-absorbent dressing application) at the time of removal of thoracostomy tube drain in patients who have had chest tube insertion.
A prospective randomized controlled study was undertaken to compare the postoperative analgesic effect between ultrasound-guided serratus anterior plane block and intercostal nerve block after single port video-assisted thoracoscopic surgery with primary spontaneous pneumothorax.
Pneumothorax is a common life-threatening complication, frequently seen in patients who have been admitted to the emergency department and intensive care unit. This study aimed to describe the features of patients with pneumothorax due to blunt or penetrating trauma. A total of 615 patients admitted to the emergency department between January 2008 and December 2010 due to multi-trauma, and underwent both chest x-ray and computed chest tomography were included in the study. There were 157 patients with a diagnosis of pneumothorax. Fifty-five of them were excluded because of the eligible criteria. The final study population included 105 patients. The computed chest tomography reading was considered as the gold standard for the occult pneumothorax diagnosis. Data on patient characteristics, trauma types, accompanied traumas, etiology of the chest trauma, and chest x-ray, and computed chest tomography results were recorded.
According to the problems of traditional closed thoracic drainage in clinical work, this study aims to further improve and improve the new closed thoracic drainage system by changing the material of drainage tube, increasing the regulating valve of external fixator and increasing the gas flow monitoring kit for special patients, so as to expand its clinical application scope and formulate its operation. Standardize. At the same time, through a randomized controlled study, the simplicity, effectiveness and safety of the new minimally invasive thoracic closed drainage system developed by the research group were deeply studied.
This is a prospective clinical trial with each patient serving as his/her own control. Patients will be recruited in three different Hong Kong hospital. All patients at the recruitment centers with ongoing air leak after ≥ 3 days from the initial diagnosis of SSP will be approached by site investigators. Patient consented to enter the study will have their rate of air leak measured on day 3 (or after if enrolled later than day 3) byreplacing the conventional chest drain system with the digital chest drainage device (Thopaz). Autologous blood patch will be instilled if the patient still has persistent air leak on day 5 of chest drain insertion ( or 48 hours of electronic chest drain measurement of airleak).
Abstract: INTRODUCTION: Pneumothorax and hydro-pneumothorax are the most common thoracic injuries and poses a risk of serious morbidity.To prevent the lung from collapsing in such condition, pleurodesis procedure is performed either with surgical pleurodesis,or chemical pleurodesis which adheres outside the lung to the inside chest cavity. The common chemicals that are used are bleomycin, tetracycline, minocycline, slurry of talc and povidoneiodine. In developed countries, the most common chemical agent used is talc, tetracycline derivatives and bleomycin. However, its clinical results depend on the level of collapse of the lung on the affected side.Internationally, for spontaneous pneumothoraces, talc is the best chemical for pleurodesis procedure which is insufflation through thoracoscopy. However its safety is debateable especially in acute respiratory disease after its administrationwhich made it null and vide consequently. Secondly, in developing countries,medical grade talc availability and affordability remains a constraint. The other suitable chemical is Iodopovidone which is inexpensive and widely used as topical antiseptic in many countries. It also hasshown a safe and effective chemical agent for pleurodesis procedure. OBJECTIVES: To determine the efficacy, safety and reoccurrence rate of in pneumothorax and hydro-pneumothorax patients after procedure with talc and pyodine pleurodesis: A comparative study. MATERIALS AND METHOD: On the basis of inclusion criteria, the selected 104 patients will be grouped (talc and pyodine) through Non probability, purposive sampling method. In each group 52 willing participants will be included without considering the size of pneumothorax. Six readings of each individual participant will be taken (3 before procedure and 3 after procedure for each group) for pulse and respiratory rate, fever, and total counts of leukocyte. Pain will be assessed on analogue scale. The readings will be taken with 8 hours gap apart. Re-occurrence will be determined after 6 months period of the procedure along with complications if any. The results of both groups will be compared for Efficacy, Safety and Re-occurrence of Pneumothorax and Hydro-pneumothorax. KEYWORDS: Pyodine pleurodesis, Talc, hydro-pneumothorax, iodopovidone, pleural effusion, pneumothorax, malignant/prevention & control; Pleurodesis/methods; Recurrence
The study will assess the safety and feasibility of a new medical device, MIPP-Kit, for the prevention of complications during diagnostic, CT guided ,percutaneous lung needle biopsy.