Clinical Trials Logo

Clinical Trial Summary

Anesthesia quality and safety have improved over the past decades, thanks to improved monitoring devices. No nociception monitoring is currently part of the standard of care. Usually, hemodynamic parameters are used to evaluate nociception (heart rate, HR, and mean arterial pressure, MAP), but none of them are specific. However, nociception evaluation is critical. Indeed, where excess of nociception can lead to arterial hypotension and respiratory depression, insufficient nociception can lead to acute postoperative pain, which is followed by persistent chronic pain in 10-50% of patients. Different monitoring devices have been developed but none of them are still used in current practice. Recently developed, the nociception level (NoL) index (MEDASENSE BIOMETRICS Ltd®, Ramat Gan, Israel) is an index of nociception, based on a nonlinear algorithm combination of heart rate, heart rate variability, photoplethysmograph wave amplitude, skin conductance, skin conductance fluctuations, and their time derivatives. Robotic surgeries have started to spread over the world 20 years ago, claiming to be mini-invasive with less hemorrhage complications, with better success based on the technical advantages of the robot allowing better access during anatomical challenges procedures. Robotic surgery has been suggested to decrease pain during surgery and post-operatively, because of the decreases abdominal wall constraints induced by the robotic arms compared to the surgeon arms. This observational prospective non-interventional monocentric study intend to evaluate the performance of the NoL index to discriminate protocol-defined nociceptive from non nociceptive stimuli during robotic surgery. All patients, scheduled for a robotic surgery procedure, will be orally informed about the study during the anesthesia consultation. During the procedure, the anesthesia procedure will be the same for all patients, as part of the usual care in our department. The NoL monitor will be added for the purpose of this study, but the results will be hidden from all physicians. All settings will be left the physician in charge. At the end of the surgical procedure, before transfer to the recovery room, data for the monitor will be extracted on a dedicated universal serial bus (USB) key. Files will be safely stored under RedCap before analysis.


Clinical Trial Description

Anesthesia quality and safety have improved over the past decades, thanks to improved monitoring devices. Excess of anesthetics could lead to arterial hypotension which has been shown to be associated with increased cardiovascular events. On the other hand, insufficient anesthetics could lead to awareness and memorization during general anesthesia (GA). Whereas almost all drugs currently used in the operating room (OR), have a validated monitoring tool, no nociception monitoring is currently part of the standard of care. Usually, hemodynamic parameters are used to evaluate nociception (heart rate (HR), and mean arterial pressure (MAP)), but none of them are specific and several factors in the OR influence these parameters. There is growing interest in the literature for nociception monitoring. Indeed, where excess of nociception can lead to arterial hypotension and respiratory depression, insufficient nociception can lead to acute postoperative pain, which is followed by persistent chronic pain in 10-50% of patients. Opioids per se can also induce nausea and vomiting, hyperalgesia for remifentanil. Different monitoring devices, like the surgical pleth index, pupillometry or the "Analgesia Nociception Index", have been developed, based on several variables and algorithms, but none of them are still used in current practice. One of the major reason is that although they might had some effects on clinical parameters or drugs consumption, none of them had any influence on patient outcome. Recently developed, the nociception level (NoL) index (MEDASENSE BIOMETRICS Ltd®, Ramat Gan, Israel) is an index of nociception, based on a nonlinear algorithm combination of heart rate, heart rate variability, photoplethysmograph wave amplitude, skin conductance, skin conductance fluctuations, and their time derivatives. One of the first study to report the ability of the NoL index to discriminate noxious from non-noxious stimuli with high sensitivity and specificity was performed in 2016. In that randomized trial (continuous infusion of remifentanil target 2 versus 4 ng/ml) enrolling 58 patients undergoing a large range of surgery, the NoL index was superior than the hemodynamic parameters alone to characterize nociception. In a study enrolling 72 patients randomized within 6 remifentanil concentration targets undergoing several surgical procedures by the same authors, the NoL index was not affected by remifentanil doses, whereas it had an dose-dependent hemodynamic effect on HR and MAP. Robotic surgeries have started to spread over the world 20 years ago, claiming to be mini-invasive with less hemorrhage complications, with better success based on the technical advantages of the robot allowing better access during anatomical challenges procedures. Debates recently arise based on the procedures cost and the little (or lack) of evidence of mini-invasive procedures in patients with cancers. Robotic surgery has been suggested to decrease pain during surgery and post-operatively, in gynecologic, thoracic, and general procedures although results are controversial, because of the decreases abdominal wall constraints induced by the robotic arms compared to the surgeon arms. To our knowledge, none of these studies evaluated pain based on a nociception monitoring device. This observational prospective non-interventional monocentric study intend to evaluate the performance of the NoL index to discriminate nociceptive from non nociceptive stimuli during robotic surgery. All patients, scheduled for a robotic surgery procedure, will be orally informed about the study during the anesthesia consultation. During the procedure, the anesthesia procedure will be the same for all patients, as part of the usual care in our department. Patients will be closely monitored by electrocardiogram, intermittent blood pressure by arm cuff, continuous pulse oximetry by finger probe, neuromuscular monitoring by train-of-four (TOF)-Cuff, bispectral index (BIS) monitoring using the BIS forehead 4-sensor. The NoL monitor will be added for the purpose of this study, but the results will be hidden. The probe will be placed on the hand contralateral to the blood pressure arm cuff. Anesthesia will be delivered by target-controlled infusion of remifentanil and propofol by two separate infusion pumps. Once consciousness will be lost and a TOF calibration done, neuromuscular blockade will be performed by rocuronium 0.6 mg/kg. All settings will be left the physician appreciation. Different stimuli (nociceptive and non-nociceptive) are defined according to protocol (such as intubation, incision, surgical haemostasia, urinary track catheter…) and their time of arrival will be collected in a Case Report Form. At the end of the surgical procedure, before transfer to the recovery room, data for the monitor will be extracted on a dedicated USB key. Files will be safely stored under RedCap before analysis. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04566536
Study type Observational
Source Assistance Publique - Hôpitaux de Paris
Contact
Status Completed
Phase
Start date October 7, 2020
Completion date April 22, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04580030 - Tricuapid Annular Plane Sistolic Excursion Before General Anesthesia Can Predict Hypotension After Induction
Active, not recruiting NCT04279054 - Decreased Neuraxial Morphine After Cesarean Delivery Early Phase 1
Completed NCT03640442 - Modified Ramped Position for Intubation of Obese Females. N/A
Recruiting NCT04099693 - A Prospective Randomized Study of General Anesthesia Versus Anesthetist Administered Sedation for ERCP
Terminated NCT02481999 - Pre- and Postoperative EEG-Monitoring for Children Aged From 0,5 to 8 Years
Completed NCT04235894 - An Observer Rating Scale of Facial Expression Can Predict Dreaming in Propofol Anesthesia
Recruiting NCT05525104 - The Effect of DSA on Recovery of Anaesthesia in Children (Het Effect Van DSA op Het Herstel na Anesthesie Bij Kinderen). N/A
Recruiting NCT05024084 - Desflurane and Sevoflurane Minimal Flow Anesthesia on Recovery and Anesthetic Depth Phase 4
Completed NCT04204785 - Noise in the OR at Induction: Patient and Anesthesiologists Perceptions N/A
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Terminated NCT03940651 - Cardiac and Renal Biomarkers in Arthroplasty Surgery Phase 4
Terminated NCT02529696 - Measuring Sedation in the Intensive Care Unit Using Wireless Accelerometers
Completed NCT05346588 - THRIVE Feasibility Trial Phase 3
Terminated NCT03704285 - Development of pk/pd Model of Propofol in Patients With Severe Burns
Recruiting NCT05259787 - EP Intravenous Anesthesia in Hysteroscopy Phase 4
Completed NCT02894996 - Does the Response to a Mini-fluid Challenge of 3ml/kg in 2 Minutes Predict Fluid Responsiveness for Pediatric Patient? N/A
Completed NCT05386082 - Anesthesia Core Quality Metrics Consensus Delphi Study
Terminated NCT03567928 - Laryngeal Mask in Upper Gastrointestinal Procedures N/A
Recruiting NCT06074471 - Motor Sparing Supraclavicular Block N/A
Completed NCT04163848 - CARbon Impact of aNesthesic Gas