View clinical trials related to Oxygen Deficiency.
Filter by:The main aim of this randomized controlled trial is to evaluate cerebral blood oxygenation after 7-day administration of a creatine-guanidinoacetic acid (GAA) mixture in healthy adults before, during, and after a series of cognitive tests.
The objective of our study is to evaluate the effectiveness of prone position in preventing intubation or death in spontaneously ventilated patients with COVID-19 with acute respiratory failure.
The type of this study is an observational prospective study. It will be done to determine the oxygenation status of the intercostal muscles and quadriceps femoris muscle during exercise in patients with fibrosing lung and to examine its relationship with exercise capacity, respiratory functions and respiratory muscle strength. The main questions that the study aims to answer are: - Question 1: Do changes in muscle oxygenation during exercise affect respiratory functions in patients with Fibrosing Lung? - Question 2: Do changes in muscle oxygenation during exercise affect exercise capacity in patients with Fibrosing Lung? Participants; demographic information such as age, height, weight will be questioned. Respiratory functions will be evaluated with a desktop spirometer, peripheral muscle strength measurement will be evaluated with a digital myometer, and functional capacity will be evaluated with a 6-minute walk test (6MWT). The Moxy device, which is a non-invasive near-infrared spectroscopy (NIRS), will be attached to the upper leg (the vastus lateralis of the quadriceps muscle) and the rib (intercostal muscles) with a silk patch, and the oxygenation of the muscles here will be measured during the 6-minute walking test. In addition, fatigue status will be evaluated with the Modified Borg Scale.
Anesthesia induction is associated with hemodynamic imbalances that can affect the blood flow to major organs. Moreover it can result in deoxygenation as well. During standard anesthesia induction the patient is manually ventilated with a circle-valve-mask system until the effect of muscle relaxant shows of. Near-infrared spectroscopy (NIRS) is a modification of a well-known peripheral pulse oxymetry that is used in the detection of the regional oxygen saturation (rSO2) in organs, including brain, liver, muscle, and intestines. In this study we will compare the regional oxygenation status of the patients during anesthesia induction in which either standard manual ventilation or mechanical ventilator-assisted ventilation was performed. AutoFlow(R) mode of Draeger-Perseus mechanical ventilator will be used for the ventilator-assisted ventilation.
With the oxygen mask with reservoir, oxygen can be given to patients with FiO2 values that can reach 80-100%. Reservoir oxygen mask is superior to other oxygen treatment methods with the high oxygen rate applied.Our hypothesis is that the use of an oxygen mask with a reservoir will reduce the incidence of respiratory complications in adult patients who will undergo sedation in the endoscopy unit.
The current methods of oxygen supply administer medicinal oxygen to the patient at a constant flow. Oxygen is being delivered when the patient needs it (at inhalation) and when the patient does not need it (at exhalation and at rest) if the volume of oxygen needs to be adjusted, the clinician typically increases the rate of flow in an effort to increase the oxygen concentration in the air inhaled by the patient. This traditional way of administering oxygen is clinically effective but it also wastes significant amounts of oxygen that the patient never uses. The BUFEO system addresses this problem by altering the supply of oxygen to an on-demand delivery model, the patient receives oxygen only when needed (during inhalation) and no oxygen is wasted at rest or during exhalation. The aim of this study is to evaluate, the efficacy, tolerability, and non-inferiority in SpO2 of the BUFEO device in saving oxygen and reaching a target SpO2 rate, in comparison to the standard of care by measuring the volume of oxygen used and the SpO2 reached when administering medical oxygen with the traditional supply method and through BUFEO system to hospitalized, oxygen-dependent subjects with pulmonary pathology.
After obtaining the approval of the hospital ethics committee, this prospective, observational study included written informed consent from 51 participants with 19<BMI<25 m/kg2 and 51 participants with BMI>40 m/kg2 undergoing an elective surgical requiring endotracheal intubation. In addition to standard monitors, an oxygen reserve index (ORI) sensor was placed and baseline values were recorded. The participants were preoxygenated until end expiratory oxygen concentration (EtO2) is reached 90%. After anesthesia induction and endotracheal intubation, the breathing circuit was not connected endotracheal tube until the peripheral oxygen saturation (SpO2) decreased until 95%.ORÄ° and SpO2 values were continuously recorded. Time of tolerable apnea, ORI warning, SpO2 warning and added warning were also recorded.
In this study, the effects of nicardipine and esmolol applied for controlled hypotension in rhinoplasty on hemodynamics and regional renal oxygenation will be investigated.
Tissue oxygen saturation monitoring was a useful indicator of blood flow insufficiency in the gastric tube leading to anastomotic leakage during radical esophagectomy.
The investigators and other groups have demonstrated that high-flow nasal oxygen used during preoxygenation for emergency surgery is at least equally effective as preoxygenation compared to standard tight fitting mask. The investigators also have data from a recent study that indicates that high-flow nasal oxygen might decrease the risk of clinically relevant desaturation below 93% of arterial oxygen saturation. The studies investigating the concept of high-flow nasal oxygen has up to this date excluded pregnant women. Pregnant woman is a patient group with known difficulties to maintain adequate saturation levels during apnoea. Due to smaller functional residual capacity their oxygen stores after preoxygenation are smaller compared to patients with a normal body mass index. The pregnant woman also have a higher oxygen demand and metabolism due to the growing placenta and the fetus. Pregnant women are therefore a patient group where a method that could prolong time until desaturation would be even more valuable and potentially could save lives. Based on the above, the investigators now aim to conduct a clinical pilot study, where pregnant women undergoing caesarian section under general anesthesia are pre and perioxygenated with high-flow nasal oxygen. Data from that group will be compared with patients preoxygenated in a traditional manner with tight facemask. This study is done to evaluate an established technique on a patient category that in theory could gain a lot from it.