The current methods of oxygen supply administer medicinal oxygen to the patient at a constant flow. Oxygen is being delivered when the patient needs it (at inhalation) and when the patient does not need it (at exhalation and at rest) if the volume of oxygen needs to be adjusted, the clinician typically increases the rate of flow in an effort to increase the oxygen concentration in the air inhaled by the patient. This traditional way of administering oxygen is clinically effective but it also wastes significant amounts of oxygen that the patient never uses. The BUFEO system addresses this problem by altering the supply of oxygen to an on-demand delivery model, the patient receives oxygen only when needed (during inhalation) and no oxygen is wasted at rest or during exhalation. The aim of this study is to evaluate, the efficacy, tolerability, and non-inferiority in SpO2 of the BUFEO device in saving oxygen and reaching a target SpO2 rate, in comparison to the standard of care by measuring the volume of oxygen used and the SpO2 reached when administering medical oxygen with the traditional supply method and through BUFEO system to hospitalized, oxygen-dependent subjects with pulmonary pathology.


Clinical Trial Description

The BUFEO system is a class 2a device that saves oxygen by altering the supply of oxygen to an on-demand delivery model through the insertion of a reservoir between the oxygen source and the patient. The reservoir accepts oxygen from the pressurized source where it is converted to ambient pressure. The BUFEO reservoir is approximately 1.75 Liters in volume and, once full, a shut-off valve automatically stops the flow of oxygen from the source and continues to hold the oxygen at ambient pressure. The rate of flow to BUFEO from the oxygen cylinder has no bearing on the volume or concentration of oxygen dispensed to the subject; the only change in the oxygen when entering the reservoir bag from the pressurized source is that it becomes ambient pressure. BUFEO is designed to be connected directly to the pressurized source, typically 50 psi in hospital settings. From the reservoir, oxygen is withdrawn on-demand by the patient's inhalation. After a certain volume is withdrawn from the BUFEO reservoir, the valve is triggered to open and refill from the pressurized source. The rate of flow from the pressurized source to BUFEO affects only the rate at which the reservoir refills upon valve opening; it has no effect on the rate of flow to the mask. Only the volume that the subject inhales on their own is dispensed at the rate of inhalation. Similar to continuous oxygen delivery systems, oxygen from the BUFEO reservoir is available to the patient at the start of the next inspiration. Unlike continuous delivery systems, the flow of oxygen to the patient stops upon the start of expiration. As a result, BUFEO's on-demand model of oxygen delivery greatly reduces waste. In addition to the conservation of oxygen dispensed, BUFEO also provides efficiency by delivering a high concentration of oxygen (99.9%) directly from the reservoir. In contrast to the standard pressurized delivery of oxygen where one titrates the concentration of oxygen upward by increasing the rate of flow, the BUFEO device requires a downward titration to reduce the concentration of oxygen. The dilution can be done by allowing a set amount of room air to be entrained and blend with the oxygen as it flows from the reservoir to the patient's mask or cannula. Safety Assessments Vital Signs Vital signs will be recorded during the study at various points. Physical Exam All subjects will undergo a brief, focused physical exam at screening that includes an examination of the heart and lungs. BUFEO device monitoring BUFEO device is an attachment to the oxygen delivery system that allows for unobstructed, on-demand access to oxygen contained in the device's reservoir. Each BUFEO device has undergone thorough quality control testing at the point of manufacturing. Each BUFEO device will also undergo testing by study staff prior to the delivery of any study assessments or treatment as indicated by instructions in the BUFEO operation manual. The study staff will also ensure that the device is turned on via examination of the device's power switch indicator prior to the delivery of any study assessments or treatment. Oxygen Monitoring Subjects will be continuously monitored by study staff during the course of the study. Subjects' oxygenation levels will also be monitored continuously with the use of a pulse oximeter, the results of which will be recorded in the study's source documents. Data Collection and Management Data Management Source documents provide evidence for the existence of the study participant and substantiate the integrity of the data collected. Study data will be recorded on the provided study source documents. Study source documents, including the participant's original signed informed consent, will be kept and securely maintained at the research site. The investigator must retain all study records and source documents for the maximum time period required by local regulations. Only study staff will have access to study source documents. Source documents will be scanned and sent to the sponsor for quality assurance and data analysis. Any queries will be sent to the study team for reconciliation. All final data will be entered into a secure Excel file using double data entry. A final review and database lock will be completed after all queries have been resolved. Confidentiality All information generated in this study is considered confidential and must not be disclosed to any person or entity not directly involved with the study without prior written consent from the sponsor. Identification of study participants will be via subject initials and assigned study numbers. Study numbers will be assigned to all subjects (including those who screen fail) at the time of screening. Any participant records or data transferred to the sponsor will contain only these identifiers. ETHICS AND RESPONSIBILITIES This study will be conducted in compliance with the protocol, Good Clinical Practice (GCP), International Conference on Harmonization (ICH) guidelines, and all applicable local regulations. The protocol will receive Institutional Review Board/Ethics Committee approval prior to the initiation of study activities. The investigator is responsible for submitting the protocol and information regarding Serious Adverse Events to the Ethics Committee. All ethics committee correspondence will be kept with the study records. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05677009
Study type Interventional
Source Oxfo Corporation
Contact
Status Completed
Phase N/A
Start date November 4, 2022
Completion date December 17, 2022

See also
  Status Clinical Trial Phase
Completed NCT04597983 - Effect of 8-week Intake of 2S-hesperidin on Performance, Body Composition and Biochemicals Markers in Amateur Cyclists N/A
Recruiting NCT05858463 - High Intensity Interval Training and Muscle Adaptations During PR N/A
Completed NCT03331471 - Alveolar Recruitment Maneuver During Pneumoperitoneum N/A
Completed NCT04626453 - Oxygenation Changes After 2-month Exercise in Sedentary Older Adults With Diabetes N/A
Enrolling by invitation NCT04322994 - THRIVE Use in Pediatric Populations- Multi Site N/A
Not yet recruiting NCT05578131 - High-flow Nasal Cannula for Pediatric Anesthetic Induction N/A
Completed NCT04612270 - Quantification of Clinically Relevant Drug Induced Changes in HbO2 Affinity N/A
Completed NCT04584788 - Validation of the O3 Regional Somatic Tissue Oxygenation Monitor N/A
Recruiting NCT04141956 - Incidence of Use of High-Flow Nasal Cannula Oxygen Therapy in Intensive Care Units Patients
Completed NCT04973046 - Tissue Oxygen Saturation for Esophagectomy
Terminated NCT03665259 - Lower Inspiratory Oxygen Fraction for Preoxygenation N/A
Recruiting NCT03396172 - FreeDom: Innovative Strategy for the Management of COPD Exacerbations N/A
Completed NCT03128372 - Validation of Next Generation Cerebral and Tissue Oximeter N/A
Completed NCT05430724 - The Effects of Nicardipine and Esmolol Applied for Controlled Hypotension N/A
Recruiting NCT05783050 - Wei Nasal Jet Tube vs Nasal Cannula Oxygen Support in Gastrointestinal Endoscopy Patients N/A
Completed NCT04711317 - Pre-oxygenation With High-flow Nasal Cannula in Caesarian Section Under General Anesthesia N/A
Completed NCT03185507 - The Effect of Cryotherapy on Cerebral Hemodynamics Within Healthy Subjects Phase 1
Completed NCT04266665 - Effect of Dexmedetomidine on Brain Homeostasis and Neurocognitive Outcome Phase 4
Completed NCT06371651 - Creatine and GAA for Brain Oxygenation N/A
Completed NCT05866289 - Awake Prone Positioning for COVID-19 Acute Hypoxaemic Respiratory Failure