Clinical Trials Logo

Clinical Trial Summary

This research will investigate the PPG signal morphology related to physiological and non- physiological changes in arrhythmia-related heart rate as well as the performance of the PPG-based features previously developed within the framework of the Mini-Holter study to discriminate between several cardiac arrhythmias. To this end, clinical data will be recorded on patients by using a wrist-based PPG monitor simultaneously with 12-lead ECG and intracardiac electrogram (EGM) signals at the university hospital in Lausanne. Importantly, this study will remain purely observational as it will not change the diagnostic and therapeutic management of the included patients, nor will it interfere with the time course of the procedures. The aim of enHEART study is to validate on a larger database the ability of several previously developed PPG-based features to detect a variety of cardiac arrhythmias.


Clinical Trial Description

The aim of the study is to acquire high quality PPG signals of various types of cardiac arrhythmias during diagnostic and therapeutic procedures, under controlled conditions (i.e., electrophysiology lab), which can be compared beat-to-beat to a concurrently-acquired, gold-standard reference (12-lead ECG and intracardiac EGM signals), and expert annotations by CHUV physicians. To this end, a total of 99 patients referred for diagnostic or therapeutic interventions (ablation) of 9 different types of cardiac arrhythmias at the CHUV will be enrolled. 11 patients per type of arrhythmia will be included. The following clinical data will be collected from the electronic file of the patient: 1. Clinical data such as age, gender, weight, size, BMI, blood pressure and heart rate, cardiovascular risk factors, clinical history 2. Baseline treatment and treatment at time of the electrophysiological procedure 3. Arrhythmia type and arrhythmia-related symptoms 4. Left and right ventricular ejection fraction as provided by the patient's private cardiologist echocardiogram. The following paraclinical data will be synchronously collected during the diagnostic and/or therapeutic intervention in the electrophysiology laboratory: 1. Surface ECG signals 2. Intracardiac EGM signals as provided by the intracardiac catheters used for the diagnostic and/or therapeutic interventions. Depending on the type of intervention, up to three different catheters may be used 3. PPG signals as provided by the PPG wrist monitor The primary objective of our study is to investigate if features extracted from the pulse morphology of PPG signals (waveform-based features) significantly improve the classification accuracy of cardiac arrhythmias compared to a classification based on heart rate variation (HRV) features only. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04884100
Study type Interventional
Source Centre Hospitalier Universitaire Vaudois
Contact
Status Completed
Phase N/A
Start date September 15, 2021
Completion date July 21, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A