Clinical Trials Logo

Clinical Trial Summary

Urinary Tract Infection (UTI) is the most common hospital acquired infection worldwide, and is most commonly associated with catheterisation of the bladder. Catheter associated urinary tract infection (CAUTI) causes increased hospital costs, increased length of stay and increased mortality. This burden of disease is, in part, mediated by a lack of diagnostic and monitoring modalities for CAUTI. Both traditional and novel UTI diagnostic tests are susceptible to false positives associated with bacterial colonisation, and correlate poorly with clinically meaningful symptomatic CAUTI. As such, the current standard of care is reliant on clinical monitoring, which is susceptible to diagnostic delays, over and under treatment. Imperial College London have developed a wireless biosensor for continuous monitoring of catheter-urine biochemistry. This project aims to validate this biosensor and demonstrate it's potential for preemptive CAUTI diagnosis through continuous urinary biochemical monitoring.


Clinical Trial Description

This research project aims to demonstrate that continuous urinary biochemical monitoring using a Smart Catheter biosensor can provide rapid diagnosis of impending catheter associated urinary tract infection (CAUTI). The primary research question will then be: "Does the Smart Catheter device reduce the time to diagnosis of CAUTI?" This will be accomplished through four studies: The aim of the first study will be to show the reliability and robustness of the Smart Catheter device through the question: "Is there any difference between the biochemical measurements from the Smart catheter device and a gold-standard laboratory measurement?" The aim of the second and third studies aim to demonstrate the different biochemical profiles of infected and healthy urine by addressing the research question: "What is the difference in biochemical concentrations in healthy urine as compared to infected urine?" Study 3 will accomplish this by comparing infected human catheter-acquired urine as compared to uninfected human catheter-urine. Study 3 will monitor the changes in biochemical changes in an artifical bladder with artificial urine over time while an infection is induced. The final study will demonstrate the reduced time to diagnosis in a clinical setting by addressing the research question: " What is the time difference in diagnosis of CAUTI from the CAUTI as compared to the current standard of clinical monitoring?" ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04315129
Study type Interventional
Source Imperial College London
Contact
Status Completed
Phase N/A
Start date April 1, 2018
Completion date July 31, 2021

See also
  Status Clinical Trial Phase
Completed NCT03287089 - Nitrofurantoin Administration for the Prevention of Short-Term Catheter Associated Urinary Tract Infection After Pelvic Surgery Phase 4
Recruiting NCT05860231 - Comparative Study Between Foley and T-Control® Catheter in Patients With Long-term Catheterization N/A
Not yet recruiting NCT06319352 - Evaluation of Quality-of-Life Improvements Using UroShield Device N/A
Completed NCT05309317 - Preventing Catheter-Associated Urinary Tract Infections With a Virtual Simulation Game N/A
Not yet recruiting NCT05913180 - Vitamin C Effectiveness in Preventing Urinary Tract Infections After Gynecological Surgeries Phase 2
Completed NCT06295627 - The Analysis of Factors Causing Indwelling Urinary Catheter-related Infections in ICU Patients and Their Nursing Strategies
Active, not recruiting NCT05485051 - Daily Chlorexidine Bath for Health Care Associated Infection Prevention Phase 3
Withdrawn NCT05643950 - Effectiveness and Cost-effectiveness of the T-Control® Catheter in Patients With Acute Urine Retention N/A
Completed NCT03645967 - Efficacy of a Prepackaged Cleansing Cloth and Standardized Cleansing Protocol for Catheter Care at Reducing CAUTI Rates N/A
Terminated NCT01108757 - Prevention of Catheter-Associated Urinary Tract Infection in Incontinence and Reconstructive Pelvic Surgery Patients N/A