Clinical Trials Logo

Clinical Trial Summary

Intravenous catheters are often placed in large (central) veins in critically ill patients to provide special medications or frequent blood sampling. The body reacts to the presence of foreign material by forming a biofilm on the surface within the catheter. Either due to the patients condition or to emergency access to these intravenous lines can become infected with bacteria and reside within the biofilm. When bacteria is grown from these lines it is referred to as: a central line infection. A medical device company (ICU Medical) has obtained the rights to a device that delivers a controlled amount of a cleaning material called chlorhexidine into the catheter to prevent bacterial growth when not in use. Chlorhexidine is the standard cleaning material used on patients when cleaning the skin for surgical procedures or central intravenous catheter insertion. In laboratory tests and animal studies that chlorhexidine inhibits the growth of bacteria and fungi that often cause central line infections. This study will the first assessment in patients with central lines.


Clinical Trial Description

Randomization Randomization will be determined using an online random number generator. "www.randomize.net". The research coordinator will randomize the patients and provide bedside staff with the devices when appropriate. Intervention Eligible patients that have provided informed consent will be randomized to receive: 1. Steril-flow® (CHG-Lock™) device OR 2. Usual care Test Protocol 1. For patients randomized to the CHG-LockTM device, attach a attach a BD Posiflush ™ 0.9% Sodium Chloride (Na Cl) 10ml syringe and a CHG-Lock™ device for each IV line that is to be locked. Follow hospital approved protocol for flush, volumes and hand hygiene (see appendix I, II and III). After a Catheter has been locked, before re-accessing the catheter for further sampling or infusions, all fluid should be aspirated from the catheter to clear the device of CHG, Heparin and the like. This should also confirm patency of the device. 2. Discard the syringe and device in biohazard waste. 3. "Blue Cap" the IV as per routine practice. - There is no need to use the CHG-Lock™ device for IV lines with IV solutions infusing or those attached to an IV pressure bag, to maintain IV patency. - If the Central Line IV is blocked, access is done by withdraw 2-3 ml discard of blood, flush with 20 mls. - If a line is blocked, do not force, the order must be obtained for Cathflo and administered by a certified Cathflo nurse. - A CHG-Lock™ device will be applied with every intravenous flush for patients in the Active (CHG-LockTM ) arm. - Bedside nurses will be educated on the use of the CHG-Lock™ device. - The device will be used for every central line and peripheral IV instillation. - All locking solutions must be removed prior to access. This is standard of practice. - Bedside nurses will be asked to document application of the device and instillation in the medication profile. - Pre-printed Physician Order Set will be created to ensure compliance with device use and protocol. - A box with devices will be placed at the bedside to ensure ease of access for nurses and that patients receive the device at every lock episode. Duration of intervention: - The intervention will be used while the central line or peripheral IV remains in situ. - The intervention will be discontinued when the patient leaves the ICU or the IV is discontinued. Measures to be taken to ensure compliance: 1. Study boxes labeled with patient name and ID at the bedside. 2. Staff education (see 3.13) 3. Daily oversight by research coordinator/Assistant ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03309137
Study type Interventional
Source Hamilton Health Sciences Corporation
Contact
Status Completed
Phase N/A
Start date November 19, 2017
Completion date November 30, 2020

See also
  Status Clinical Trial Phase
Completed NCT04529421 - Assocation Between In-person Instruction and COVID-19 Risk
Recruiting NCT04081792 - Optimal Antibiotics for Operated Diabetic Foot Infections N/A
Completed NCT04332861 - Evaluation of Infection in Obstructing Urolithiasis
Recruiting NCT04674657 - Does Extra-Corporeal Membrane Oxygenation Alter Antiinfectives Therapy Pharmacokinetics in Critically Ill Patients
Enrolling by invitation NCT05052203 - Researching the Effects of Sepsis on Quality Of Life, Vitality, Epigenome and Gene Expression During RecoverY From Sepsis
Recruiting NCT00342589 - New Techniques for Using a Saline Wash as a Diagnostic Tool for Pneumocystis Pneumonia
Completed NCT03295825 - Heparin Binding Protein in Early Sepsis Diagnosis N/A
Completed NCT03296423 - Bacillus Calmette-guérin Vaccination to Prevent Infections of the Elderly Phase 4
Withdrawn NCT04217252 - Clinical Application of High-throughput Sequencing Technology for the Diagnosis of Patients With Severe Infection N/A
Recruiting NCT02905552 - Myelodysplasic Syndromes and Risk Factors for Infection N/A
Recruiting NCT02899143 - Short-course Antimicrobial Therapy in Sepsis Phase 2
Withdrawn NCT02904434 - Gastrointestinal Implications of Voriconazole Exposure
Active, not recruiting NCT02768454 - Antimicrobials Stewardship by Pharmacist N/A
Completed NCT02219776 - Decreasing Infection In Arthroscopic Shoulder Surgery N/A
Completed NCT02210169 - RCT of Continuous Versus Intermittent Infusion of Vancomycin in Neonates N/A
Recruiting NCT02098226 - Evaluation of MALDI Biotyper CA System for Detection of Gram- and Gram+ Bacteria and Yeasts N/A
Completed NCT01846832 - A Study of TMC435 Plus Pegylated Interferon Alfa-2a and Ribavirin in Participants With Chronic HCV Infection Phase 3
Terminated NCT01441206 - Safety and Pharmacokinetics of Single and Multiple Dose Rifampin in Infants Phase 1
Completed NCT01434797 - Value of PET/CT Imaging in the Diagnosis of Permanent Central Venous Catheters Infection
Completed NCT01159834 - Human Papillomavirus (HPV) Vaccination in Barretos (Pio XII Foundation - Barretos Cancer Hospital) N/A