Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00635206
Other study ID # BIPAP Rescue
Secondary ID ABF-2007-MCT-03
Status Completed
Phase Phase 3
First received March 6, 2008
Last updated July 13, 2009
Start date September 2007
Est. completion date May 2009

Study information

Verified date July 2009
Source Clayton Sleep Insititute
Contact n/a
Is FDA regulated No
Health authority United States: Institutional Review Board
Study type Interventional

Clinical Trial Summary

The primary objective outcome is the proportion of participants compliant (at least four hours of use per night for all nights) in the Auto Bilevel group compared to the CPAP group after 90 days of treatment during the investigation. Proportion will be calculated using the cumulative number of hours on therapy divided by the total number of days of the investigation for each participant. The mean and standard deviation of these mean therapy hours will then be calculated for each arm of the investigation. Participants with compliance of at least four hours will be classified as "compliant" and those with less than four hours will be classified as "non-compliant". The null hypothesis will be rejected if the mean of the primary objective outcome for all participants in the BiPAP® Auto with Bi-Flex® therapy arm is significantly greater than that for all participants in the CPAP therapy arm.

Secondary Measures

The secondary measures used to evaluate potentially improved adherence to BiPAP® Auto with Bi-Flex® therapy compared to CPAP therapy will include:

- Hours of use per night, for all nights

- Hours of use per night, for nights with therapy use

- Device derived AHI

- Heart Rate Variability

- Functional Outcomes of Sleep Questionnaire (FOSQ),

- 10 cm Visual Analog Scale (VAS) for mask comfort and satisfaction with therapy,

- Epworth Sleepiness Scale (ESS) questionnaire

- Psychomotor Vigilance Task

- Attitudes toward use

- Actigraphy (sleep continuity) and sleep diary

- Fatigue Severity Scale

- Daytime Functioning Scale


Description:

The hypothesis of this investigation is that the BiPAP® Auto with Bi-Flex® improves acceptance of and adherence to positive pressure therapy in participants who are newly diagnosed with OSA and who meet objective criteria for PAP failure during their initial encounter with CPAP in the sleep laboratory.

This hypothesis will be tested using a two-arm, randomized, double-blind design. Participants failing to tolerate CPAP therapy in the sleep laboratory during their titration night will be randomized to a BiPAP® Auto with Bi-Flex® titration or a CPAP titration night in the lab. Participants will then go home with their respective therapy for three months.


Recruitment information / eligibility

Status Completed
Enrollment 51
Est. completion date May 2009
Est. primary completion date May 2009
Accepts healthy volunteers No
Gender Both
Age group 21 Years to 75 Years
Eligibility Inclusion Criterion:

1. Age 21-75

2. New Diagnosis of OSA with a baseline RDI = 15 events/hr of sleep determined by either full night or split night PSG

3. Able and willing to provide written informed consent

4. Able to follow study procedures

5. Sub-optimal PSG titration with at least 3 hours of attempted PAP titration (defined below): and deemed by their physician as a titration failure

Sub-optimal PSG titration: at least one of the following:

1. Poor sleep efficiency during titration period (sleep efficiency = 70%) (participants may be on sleep medications as per standard lab CPAP protocol ) or;

2. Frequent arousals based on three seconds of alpha frequency on EEG (non PLM-related) of 20 or greater per hour during the titration portion of the study or;

3. CPAP titration aborted due to participant's request (due to intolerance), or

4. Persistent sleep disruption despite therapeutic CPAP therapy and in the judgment of the reviewing physician, suggesting a low probability to CPAP adherence

Exclusion Criterion:

1. Participation in another interventional research study within the last 30 days

2. Major uncontrolled medical or psychiatric condition such as congestive heart failure, neuromuscular disease, renal failure etc.

3. Prior CPAP or Bi-Level PAP use (within last 2 years)

4. Chronic respiratory failure or insufficiency, moderate COPD (FEV1 < 60%), or any known condition of an elevation of arterial carbon dioxide levels while awake

5. Surgery of the upper airway, nose, sinus, or middle ear within the previous 90 days

6. Presence of an untreated, diagnosable, non-OSA related sleep disorder (e.g. restless legs syndrome, insomnia, etc.)

7. Periodic Limb movement arousal index of 10 or greater.

8. Refusal to consider further interventions to standard CPAP to optimize positive pressure therapy (e.g. different mask than what was used in lab)

9. PAP therapy otherwise medically complicated or contraindicated such as those with a difficult to size or adjust interface (mask) resulting in facial pain, skin irritation or trauma, or excessive air leaks

10. Shift workers or people experiencing jet lag

11. Known history of alcohol and or drug abuse

12. Diagnosis of Complex Sleep Apnea, (appears to be classic obstructive or mixed sleep apnea, but exhibits disruptive central apneas and periodic breathing on CPAP) 11, 12 or persistent central apnea during diagnostic PSG.

13. Diagnosis of Attention Deficit Hyperactivity Disorder

14. Chronic Hypnotic use (nightly use for three months or less)

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Investigator), Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
BiPap auto with Fi Flex
MinEPAP = 4 cmH2O for prescribed CPAP = 10 cmH2O (use 6 cmH2O for prescribed CPAP > 10 cmH2O) MaxIPAP = 25 cm H2O MinPS = 2 cm H2O (cannot be adjusted) MaxPS = 8 cm H2O Bi-Flex setting of 3
Standard CPAP
CPAP = 10 cmH2O (use 6 cmH2O for prescribed CPAP > 10 cmH2O)

Locations

Country Name City State
United States Clayton Slep Institute St. Louis Missouri

Sponsors (1)

Lead Sponsor Collaborator
Clayton Sleep Insititute

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary proportion of participants compliant (at least four hours of use per night for all nights) in the Auto Bilevel group compared to the CPAP group after 90 days of treatment during the investigation. 90 days No
Secondary ASdherence to BiPAP® Auto with Bi-Flex® therapy compared to CPAP therapy will include: compliance, AHI, HRV, FOSQ, Visual Analog Scale for mask comfort & satisfaction, ESS, PVT, Attitudes toward use, Actigraphy & sleep diary, FSS, & DFS 90 days No
See also
  Status Clinical Trial Phase
Recruiting NCT05857384 - Bioavailability, Bioequivalence and Tolerability of IHL-42X Compared to the Reference Drugs Phase 1
Recruiting NCT04547543 - Follow-up of Apneic Patients by Visio-consultation N/A
Recruiting NCT05371509 - Novel Myofunctional Water Bottle to Reduce OSA and Snoring Study N/A
Completed NCT02515357 - Mediterranean Diet/Lifestyle Intervention in Obstructive Sleep Apnea N/A
Completed NCT05582070 - Effect on Sleep of Surgical Treatment of Severe Nasal Obstruction N/A
Active, not recruiting NCT03189173 - Combined Upper-airway and Breathing Control Therapies for Obstructive Sleep Apnea Phase 2
Completed NCT04084899 - The Effect of CPAP on Lung Hyperinflation in Patients With OSA
Completed NCT03032029 - Registry on the Treatment of Central and Complex Sleep-Disordered Breathing With Adaptive Servo-Ventilation
Recruiting NCT04028011 - Clinical Evaluation of a Wearable Technology for the Diagnosis of Sleep Apnoea
Recruiting NCT06047353 - Community Health Advocates for Motivating PAP Use in Our Neighborhoods. N/A
Completed NCT05253963 - Acute Effect of CPAP on Weight in Patients With Obstructive Sleep Apnea N/A
Recruiting NCT06029959 - Stroke and CPAP Outcome Study 3 N/A
Recruiting NCT06150352 - Sleep Apnea, Neurocognitive Decline and Brain Imaging in Patients With Subjective or Mild Cognitive Impairment
Completed NCT03589417 - Postural Stability, Balance and Fall Risk in Patients With Obstructive Sleep Apnea
Recruiting NCT04335994 - ENhancing Outcomes in Cognitive Impairment Through Use of Home Sleep ApNea Testing N/A
Withdrawn NCT04063436 - Evaluation of a New Nasal Pillows Mask for the Treatment of Obstructive Sleep Apnea N/A
Recruiting NCT05385302 - Sociological Determinants of Positive Airway Pressure Adherence in OSA Patients
Recruiting NCT04572269 - Metabolomics of Obstructive Sleep Apnea
Not yet recruiting NCT06467682 - 12-week Tele-exercise Program in Patients With OSA N/A
Withdrawn NCT04011358 - Retinal Vein Occlusion and Obstructive Sleep Apnea: A Case Control Study N/A