Mechanical Ventilation Clinical Trial
Official title:
Continuous Monitoring of the Lungs Ventilation Dynamics During Mechanical Ventilation by Small Surface Patches That Include Safe Motion Sensors
Background: Patients that suffer from respiratory failure and need mechanical ventilation are at risk of further deterioration due to complications induced by progression of lung disease or the mechanical ventilation. The complications usually develop in a progressive manner, but are currently detected relatively late, when there is already severe and life threatening deterioration in patient oxygenation and sometimes irreversible damages. Objective:To measure chest wall dynamics, derived from sensors placed on the chest and abdomen. Methods: The system comprises of patches attached to the chest wall and upper abdomen that include mechanical sensors that measure the mechanics of lung inflation and deflation.
Patients that suffer from respiratory failure and need mechanical ventilation are at risk of further life threatening deterioration following the development of mechanical problems related to airway management, development of lung barotrauma or displacement of the endotracheal tube. Neonates especially need tight and sensitive monitoring of lung ventilation, because of the high prevalence of lung disease and need for ventilatory support in this population. Methods: The system comprises of patches attached to the chest wall and to the epigastrium. The patches include sensors that measure the mechanics of the lung inflation and deflation. Study protocol Following parental informed consent, three patches will be placed on both sides of the chest and over the epigastric area in infants that require tight respiratory monitoring. The patches will be placed just beside the ECG patches. The placement of the patches will be performed by a physician. The monitoring can be preformed as long as the baby needs a tight respiratory monitoring. The patches will be replaced according to routine replacement policy of patches in the neonatal intensive care units, and at the regular time defined by the attending staff, and no longer than 24 hours. At the end of the data acquisition, the patches will be removed. No additional intervention is required. The patient will be inspected by the supervising physician involve in the research. It will not provide any data that may alter the treatment and will not interfere or influence the other monitoring devices that are used to evaluate the clinical status of the patient. The other parameters that are regularly monitored, that are displayed on the bedside monitor and respirator will be recorded by the research assistant. The ventilated baby will be identified by a study number. There will be a separate database for the measurements and the demographic and clinical data. There will be no disclosure of the patient's identity along with the data analysis and publication of the results or communication to authorities or other medical practitioners. Equipment safety: The system is safe for the use in human subjects. The whole system is approved for safety according to the acquired standard ICE-60601 ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05921656 -
Construction and Evaluation of Airway Leakage Risk Model of Patients With Endotracheal Tube
|
||
Recruiting |
NCT03941002 -
Continuous Evaluation of Diaphragm Function
|
N/A | |
Withdrawn |
NCT04288076 -
The Brain and Lung Interaction (BALI) Study
|
N/A | |
Completed |
NCT03031860 -
Semi-quantitative Cough Strength Score (SCSS)
|
N/A | |
Completed |
NCT02312869 -
Local Assessment of Management of Burn Patients
|
N/A | |
Completed |
NCT02545621 -
A Role for RAGE/TXNIP/Inflammasome Axis in Alveolar Macrophage Activation During ARDS (RIAMA): a Proof-of-concept Clinical Study
|
||
Completed |
NCT01885442 -
TryCYCLE: A Pilot Study of Early In-bed Leg Cycle Ergometry in Mechanically Ventilated Patients
|
N/A | |
Completed |
NCT01204281 -
Proportional Assist Ventilation (PAV) in Early Stage of Critically Ill Patients
|
Phase 4 | |
Terminated |
NCT01059929 -
Dexmedetomidine Versus Propofol in the Medical Intensive Care Unit (MICU)
|
Phase 4 | |
Completed |
NCT00824239 -
Intermittent Sedation Versus Daily Interruption of Sedation in Mechanically Ventilated Patients
|
Phase 3 | |
Completed |
NCT00529347 -
Mechanical Ventilation Controlled by the Electrical Activity of the Patient's Diaphragm - Effects of Changes in Ventilator Parameters on Breathing Pattern
|
Phase 1 | |
Unknown status |
NCT00260676 -
Protective Ventilatory Strategy in Potential Organ Donors
|
Phase 3 | |
Terminated |
NCT00205517 -
Sedation and Psychopharmacology in Critical Care
|
N/A | |
Completed |
NCT03281785 -
Ultrasound of Diaphragmatic Musculature in Mechanically Ventilated Patients.
|
N/A | |
Recruiting |
NCT04110613 -
RCT: Early Feeding After PEG Placement
|
N/A | |
Completed |
NCT04410783 -
The Emergency Department Sedation Pilot Trial
|
N/A | |
Recruiting |
NCT04821453 -
NAVA vs. CMV Crossover in Severe BPD
|
N/A | |
Completed |
NCT03930147 -
Ventilation With ASV Mode in Children
|
N/A | |
Recruiting |
NCT05029167 -
REstrictive Versus LIberal Oxygen Strategy and Its Effect on Pulmonary Hypertension After Out-of-hospital Cardiac Arrest (RELIEPH-study)
|
N/A | |
Recruiting |
NCT04849039 -
Lung Microbiota and VAP Development (PULMIVAP)
|