Clinical Trials Logo

Clinical Trial Summary

Medical titanium plates are routinely used in fixing mobilized bone segments in jaw surgeries. Generally these plates are commercialized with standard construction specifications. Thus they should be repeatedly bended and arched to match the contour of anchored jaw bones before located in place and fastened by screws. To prevent stress fatigue induced by plate bending and improve structural design, we utilized the three-dimensional printing technique and developed a new production procedure in fabricating customized titanium plates according to each patient's specific skeletal contours and dimensions derived from medical imaging data. In general, the three-dimensional printing of customized implants are expected to facilitate surgical operation, reduce application duration and improve precise restoration. Up until now, the application of three-dimensional printing of titanium fixation plates in jaw surgery has been available only at two centers globally. The published preliminary work have proved the prospect of customized titanium plates in promoting mandibular reconstruction surgery and upper maxilla orthognathic surgery though their printed titanium plates looked rather bulky and the sample sizes were small and there is still lack of qualified randomized controlled trials between the printed and the conventional titanium plates. To better benefit from the burgeoning use of three-dimensional printing in health care, it is imperative to conduct a feasibility study in exploring the application of three-dimensional printing of titanium fixation plates in jaw surgery based on our patients. The aim of the study is to conduct a case series study focusing on the feasibility and safety of applying three-dimensional printed titanium plates in jaw reconstruction surgery and orthognathic surgery. The outcome measures include the success rate, potential adverse events and accuracy. A sample size of 48 subjects will be recruited prospectively. Considering the facts that titanium plates are widely used in jaw surgery and our unit is the largest oral and maxillofacial surgery center in Hong Kong, the well-designed customized titanium plate is therefore with great potential benefit for the patients in our population. Furthermore, the well-developed three-dimensional manufacturing protocol could also be applied in other relevant medical areas and push forward the personalized medicine era in the future.


Clinical Trial Description

Plate osteosynthesis is the basic philosophy in maintaining skeletal stabilization in jaw surgery. Numerous branded osteosynthesis systems are available and most of them are made from pure titanium or titanium alloys with standard construction specifications. Usually these titanium plates should be bended and arched to better match the three-dimensional contour of anchored jaw bones. However the optimal bending of the titanium plate sometimes is difficult and time-consuming especially for the inexperienced surgeons and in complicated cases. Excessive bending could also initiate residual stress and potentially worsen the mechanical properties of titanium plates(1). The three-dimensional (3D) printing, or additive manufacturing, has been well developed in fabricating customized materials from the computer-generated digital files. In recent years, 3D printing of patient-specific medical implants has been evolving with the newly-emerged technology of powder bed fusion, which enabled the melting of metals and further shaping of devices(2). In September 2015, China's innovative 3D printed hip joint prosthesis was commercially certified by China's State Food and Drug Administration. In February 2016, the world's first 3D printed patient-specific titanium cranial/craniofacial plate implant got the U.S. Food and Drug Administration's approval. Beyond that, a number of other printed implants have showed excellent performance in clinical research. These printed medical implants are majorly from pure titanium or Ti6Al4V alloy, which exhibit good resistance to fatigue and corrosion and are considered the most biocompatible metal(3). Relying on individualized imaging data, the printed implants are patient-specific and adapt to the anatomical structures precisely. Since the additive manufacturing is ultimately different from the conventional multi-step production operations, it could reduce costs and lead times, especially in printing complex devices for individualized cases. While in clinical applications, 3D printing of customized implants are expected to facilitate surgical operation, reduce application duration and improve precise restoration(4). It is predicted the application of 3D printing technique in medical area may bring forward another major advance toward personalized medicine(5). Many more customized medical implants will be approved in the future across the world. With the advent of metal additive manufacturing, the 3D-printed patient-specific titanium plates have been successfully fabricated. In 2012, Per Derand et al. reported the first application of 3D-printed titanium plates with the established workflow from imaging, via virtual design, to manufacturing of cutting guide and customized titanium reconstruction plates, and its utility in the fibula-based mandibular reconstruction surgery. The pre-printed plates did facilitate the operation and reduced the operation duration about half an hour though the postoperative accuracy of the grafted bone was modest compared with the virtual planning(6). Simultaneously, Leonardo Ciocca et al. reported the computer-aided designing and manufacturing in guiding secondary mandibular reconstruction of a discontinuity defect involving the employment of the surgical guide and printed titanium reconstruction plate in surgical transferring of virtual planning(7). In 2013, Simona Mazzoni and Leonardo Ciocca et al. applied the same surgical protocol in a study group of seven mandibular reconstruction patients and compared its advantages with the standard pre-plating technique on stereolithographic models in a control group. The results revealed the computer-aided surgical protocol was viable in reproducing the patients' anatomical contour, giving the surgeon better procedural control and reducing procedure time(8). In 2015, Simona Mazzoni et al. further developed the computer-aided designing and manufacturing technique in fabricating surgical cutting guides and titanium fixation plates in upper maxilla repositioning surgery without an occlusal wafer. The study result confirmed the high accuracy in transferring the virtual planning by using the surgical guides and fixation plates(9). In reviewing the literature, the application of 3D printing of titanium fixation plates in jaw surgery are available only at two centers currently: the Maxillofacial Surgery Department of S Orsola Malpighi Hospital in Italy and the Oral and Maxillofacial Surgery Department of Lund University in Sweden(6,7). The published preliminary work have proved the prospect of 3D-printed titanium plates in promoting mandibular reconstruction surgery and upper maxilla orthognathic surgery though their printed titanium plates looked rather bulky and the sample sizes were small and there is still lack of qualified randomized controlled trials between the printed and the conventional titanium plates. To better benefit from the burgeoning use of 3D printing in health care, we will develop a new designing and manufacturing protocol in printing customized fixation plates, which will be designed in specific loading circumstances and will perfectly adapt to the anatomical structures of the jaw. It is imperative to conduct a feasibility study in exploring the application of 3D printing of titanium fixation plates in jaw surgery based on our patients. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03057223
Study type Interventional
Source The University of Hong Kong
Contact
Status Completed
Phase N/A
Start date September 1, 2016
Completion date April 6, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT05522348 - Stability of Two Designs of Patient Specific Osteosynthesis For Fixation of LeFort 1 Osteotomy in Orthognathic Surgery N/A
Completed NCT03913429 - Ultrasound-guided Bilateral Suprazygomatic Maxillary Nerve Block and Bimaxillary Osteotomy N/A
Recruiting NCT04117360 - Orthognathic Speech Pathology: Phonetic Contrasts of Patients With Dental Discrepancies Pre- and Post-Treatment Analyses
Recruiting NCT06140043 - Augmented Reality for Orthognatic Surgery Patient Education Phase 2/Phase 3
Completed NCT04863170 - Cross Cultural Adaptation and Validation of Orthognathic Quality of Life Questionnaire (OQLQ)
Completed NCT06132906 - Comparison Between Two Techniques to Reposition the Maxilla After le Fort 1 N/A
Recruiting NCT05151042 - Digital Occlusal Wafer Versus Waferless Distal Segment Repositioning for BSSO in Skeletal Mandibular Deformities N/A
Completed NCT04224805 - The Use of Bone-borne Guides in Orthognathic Surgery Cases N/A
Recruiting NCT05340036 - Skeletal Stability of Le Fort I Osteotomy Using Patient-specific Osteosynthesis Compared to Mini-plate Fixation for Patients With Dentofacial Disharmony N/A
Completed NCT05060133 - Changes of the Upper Airway Volume After Orthognathic Surgery
Recruiting NCT02889432 - Effects of Oral Melatonin on Neurosensory Recovery Following Facial Osteotomies Phase 2
Completed NCT02491619 - Correlation Between Dental Inclination and Bone Thickness in Patients With Class III Dentofacial Deformities N/A
Recruiting NCT05755022 - 3D Photogrammetry Versus Commercial Scanners for Accurate Repositioning of the Maxilla for Correction of the Dentofacial Deformity. N/A
Completed NCT03974035 - Does it Worth to Reinforce With Additional Anesthesia to Improve Postoperative Course After Orthognathic Surgery? Phase 2
Active, not recruiting NCT03652155 - Evaluating the Relationship Between Hard and Soft Tissue Advancement in Orthognathic Surgery
Recruiting NCT04635865 - 3D-Printed Patient-Specific Surgical Plates Versus Conventional Surgical Plates in Jaw Reconstruction N/A
Active, not recruiting NCT03532828 - Interaction Between Body Posture and Nocturnal Sleeping Disorders in Dysgnathic Patients N/A
Completed NCT04464252 - Development and Validation of an Automated Three-dimensional Cephalometry Method
Recruiting NCT02639312 - Natural History of Craniofacial Anomalies and Developmental Growth Variants