Keratoconus Clinical Trial
— LinkCorOfficial title:
Evaluation of Safety and Efficacy of Intrastromal Implantation of LinkCor Bioengineered Corneal Implant for Management and Treatment of Keratoconus: a Prospective, Non-randomized, Non-controlled Case Series.
This is a prospective, Phase I open-label safety study to evaluate the safety, feasibility and initial efficacy of a bioengineered corneal stromal substitute after implantation into the stroma of adults with advanced keratoconus. The bioengineered substitute and implantation technique may provide a less invasive treatment option for advanced keratoconus than current surgical approaches, that additionally does not rely on the limited availability of human donor corneal tissue.
Status | Recruiting |
Enrollment | 40 |
Est. completion date | July 31, 2024 |
Est. primary completion date | December 31, 2023 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Advanced keratoconus (according to Amsler-Krumeich classification) - No corneal scar - Male or female aged = 18 years, no upper age limit - Subjects indicated for a first corneal stromal transplantation (treatment naïve) - Corneal thickness (including epithelium) at least 300µm centrally, as measured by OCT. - Patients who gave their written signed and dated informed consent for participation Exclusion Criteria: - Prior corneal surgery (e.g., refractive surgery, cataract, collagen cross-linking, endothelial keratoplasty, etc.) - Dry eye / tear film pathology - Active ocular infection - Glaucoma / ocular hypertension - Active corneal ulceration - Acute or chronic disease or illness that would increase the operation risk or confound the outcomes of the study (immune- compromised, connective tissue disease, clinically significant atopic disease, etc.) - Any other medical condition that in the judgment of the clinical investigator or corneal surgeon is not compatible with the study procedures - General history judged by the investigator to be incompatible with the study (e.g., life-threatening patient condition, other condition where postoperative follow-up may be difficult). - known diabetes or other neuro-degenerative disorder (as corneal nerves can be affected leading to impaired wound healing) - Inability of patient to understand the study procedures and thus inability to give informed consent. - Participation in another clinical study within the last 3 months - Already included once in this study (can only be included for one treated eye). |
Country | Name | City | State |
---|---|---|---|
India | All India Institute of Medical Sciences, Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, | New Delhi | |
Iran, Islamic Republic of | Farabi Eye Hospital, Tehran University of Medical Sciences | Tehran |
Lead Sponsor | Collaborator |
---|---|
LinkoCare Life Sciences AB |
India, Iran, Islamic Republic of,
Rafat M, Jabbarvand M, Sharma N, Xeroudaki M, Tabe S, Omrani R, Thangavelu M, Mukwaya A, Fagerholm P, Lennikov A, Askarizadeh F, Lagali N. Bioengineered corneal tissue for minimally invasive vision restoration in advanced keratoconus in two clinical cohor — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Safety outcome measure | The primary safety endpoint is defined such that a rejection leading to implant removal should occur in no more than 10% of implanted eyes. The implant rejection is defined as a clinical situation when the implanted eye has decreased central corneal clarity and decreased implant clarity, corneal vascularization inside of laser created pocket and inflammation. | 6 months | |
Primary | Corneal curvature measured by keratometry (efficacy measure) | The maximum and minimum corneal curvature (steepness) of each eye will be measured by a keratometer and reported in diopter (D) unit and represented as "K-value". The efficacy outcome is that more than 60% of the eyes should have a decrease in K-value at 6 months postoperatively. | 6 months | |
Primary | Central corneal thickness measured by topography techniques (efficacy measure) | Central corneal thickness (CCT) will be measured in microns and reported using a two-dimensional thickness map made by optical coherence tomography (OCT) and/or Pentacam topography. The efficacy outcome is that more than 60% of the eyes should have an increase in CCT at 6 months postoperatively. | 6 months | |
Primary | Visual acuity (efficacy measure) | Vision improvement equivalent of minimum one line in Snellen chart in uncorrected distance visual acuity (UDVA) or corrected distance visual acuity (CDVA). | 6 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04570020 -
Scleral Lens Fitting Using Wide-Field OCT
|
||
Recruiting |
NCT02921009 -
McNeel Eye Center Corneal Crosslinking Study
|
N/A | |
Completed |
NCT01691651 -
Botulinum Toxin A for the Treatment of Keratoconus
|
N/A | |
Terminated |
NCT02762253 -
Study of the Safety and Effectiveness of Photochemically Induced Collagen Cross-Linking in Eyes With Keratoconus.
|
Phase 2 | |
Completed |
NCT01527708 -
Accuracy of Curvature and Wavefront Aberrations of Posterior Corneal Surface, in Keratoconic and Post-CXL Corneas
|
N/A | |
Completed |
NCT01527721 -
Blurring Strength & Aberrometric Changes Following Corneal Cross-linking (CxL) and CxL Combined With Photorefractive Keratectomy (PRK) in Keratoconus
|
N/A | |
Recruiting |
NCT00841386 -
Treatment of Keratoconus Using Collagen Cross-Linking
|
Phase 2/Phase 3 | |
Completed |
NCT00347074 -
A Clinical Study of Keratoconus in Asian Patients and Assessment of Different Topographic Patterns of Keratoconus in Asian Patients
|
N/A | |
Completed |
NCT03187912 -
Accelerated Corneal Cross-linking With Different Riboflavin Solutions
|
Phase 3 | |
Completed |
NCT00584285 -
Corneal Topographer Fluorescein Patterns
|
||
Completed |
NCT03511495 -
Reliability of Topography Measurements in Keratoconus
|
||
Not yet recruiting |
NCT05395650 -
Cyanocobalamin as Photosensitizing Agent
|
||
Completed |
NCT04418999 -
Safety and Efficacy of Intracanalicular Dexamethasone Compared to Loteprednol Etabonate in Patients With Keratoconus
|
Early Phase 1 | |
Completed |
NCT03235856 -
Retrospective Digital Computer Analysis of Keratoconus Evolution - REDCAKE
|
||
Completed |
NCT05019768 -
Topo-pachimetric Accelerated Epi-On Cross-linking Compared to Dresden Protocol Using Riboflavin With Vitamin E TPGS
|
N/A | |
Withdrawn |
NCT01789333 -
Higher Irradiance in Keratoconus Ectasia
|
N/A | |
Completed |
NCT05114928 -
Correlation Between Q-value Changes and Progression of Pediatric Keratoconus.
|
||
Completed |
NCT03647046 -
Custom Anterior Surfacing of Scleral Lens for Vision Quality Improvement in Patients With Keratoconus
|
N/A | |
Recruiting |
NCT04439552 -
fMRI and IVCM Cornea Microscopy of CXL in Keratoconus
|
||
Recruiting |
NCT06100939 -
Epithelium-On Corneal Cross-linking in Subjects 8 to 45 Years of Age With Keratoconus
|
Phase 3 |