Clinical Trials Logo

Clinical Trial Summary

This study aims to evaluate the efficacy and safety of abluminal biodegradable polymer ultrathin sirolimus-eluting stent (Genoss stent) as compared with a durable-polymer everolimus-eluting stent (Xience stent) in patients with coronary artery disease.


Clinical Trial Description

After the introduction of the drug-eluting stents (DES), the rates of device-related failure or target lesion failure (TLF) such as restenosis has been markedly decreased, compared with the era of bare-metal stents. Nevertheless, the risk of ischemic events including very late stent thrombosis after percutaneous coronary intervention (PCI) has still remained even though the use of DES, presumably because of hypersensitivity to the polymer with persistent inflammation and delayed re-endothelialization. To overcome these issues, second-generation DES with thinner stent strut and biocompatible or biodegradable polymer were developed. Several trials demonstrated that second-generation DES provides more favorable outcome in comparison with first-generation DES. Especially, among second-generation DES, biodegradable polymer DES showed better ischemic outcomes compared to durable polymer DES in some studies. Genoss DES™ (Genoss Company Limited, Suwon, Korea) is one of newer second-generation DESs with a cobalt-chromium platform with an abluminal biodegradable polymer containing sirolimus. The Genoss DES™ is the first Korean sirolimus-eluting stent on the market and it has ultrathin strut with 70 μm strut thickness with 3 μm thin abluminal polymer coating containing Sirolimus. The polymer is designed to release approximately 70% of the total drug amount within 30 days of the implantation and is entirely absorbable within 9 months. Thus, only the metal component of the stent will remain. In the first-in-man trial comparing Genoss DES™ and Promus Element™ stent (Boston Scientific Co., Natick, MA, USA), angiographic and clinical outcomes were similar at a 9-month follow-up. However, the study was too small to conclude that the Genoss DES™ is safe and efficient for de novo coronary stenosis. To date, there has been no large-scale randomized trial evaluating the safety and efficacy of Genoss DES™. Therefore, the purpose of this trial is to determine the efficacy and safety of Genoss DES™ as compared with Xience everolimus-eluting stent (Abbott Vascular, Santa Clara, California, USA) which is widely used and has proven efficacy and safety. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05444452
Study type Interventional
Source Samsung Medical Center
Contact Hyeon-Cheol Gwon, MD, PhD
Phone 82-2-3410-3694
Email hcgwon@naver.com
Status Recruiting
Phase N/A
Start date April 24, 2022
Completion date June 30, 2027

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Active, not recruiting NCT04562805 - Infinity-Swedeheart Registry Based Randomized Clinical Trial (R-RCT) N/A
Recruiting NCT05292079 - CAPTURER PMCF Study ( rEPIC04D )
Recruiting NCT05292118 - Navitian PMCF Study ( rEPIC04C )
Recruiting NCT05292092 - Essential Pro PMCF Study ( rEPIC04E )
Recruiting NCT05292014 - ANGIOLITE PMCF Study ( rEPIC04F )
Completed NCT05292105 - NC Xperience PMCF Study( rEPIC04B)
Completed NCT03076801 - Does Choral Singing Help imprOve Stress in Patients With Ischemic HeaRt Disease? N/A
Not yet recruiting NCT04153383 - Milrinone on Cardiac Performance During Off-pump Coronary Artery Bypass Surgery
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Recruiting NCT02982434 - The New Pharmaceutical Composition Containing Botulinum Toxin to Treat Atrial Fibrillation Phase 2
Completed NCT02468401 - Prevention of Contrast Induced Nephropathy in Patients With Advanced Renal Dysfunction Undergoing Coronary Interventions N/A
Completed NCT02759406 - Evaluation of the Palmaz Mach-5 Grooved Bare Metal Coronary Stent System Versus the Palmaz Bare Metal Coronary Stent System in Patients With Symptomatic Ischemic Heart Disease: A Safety and Performance Study N/A
Recruiting NCT01681381 - Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization N/A
Completed NCT01604213 - Effects of Vildagliptin/Metformin Combination on Markers of Atherosclerosis, Thrombosis, and Inflammation in Diabetics With Coronary Artery Disease Phase 4
Completed NCT01699802 - Influence of Inhaled Anaesthetics on Rebreathing of Carbon Dioxide When Using an Anaesthesia Gas Reflector (AnaConDa) N/A
Completed NCT01724567 - Copenhagen Study of Obese Patients With Ischemic Heart Disease Undergoing Low Energy Diet or Interval Training N/A
Completed NCT01334268 - RESOLUTE China RCT N/A
Completed NCT02159235 - Heavy Metals, Angiogenesis Factors and Osteopontin in Coronary Artery Disease (CAD) N/A