Intracranial Aneurysm Clinical Trial
Official title:
A Prospective, Multicenter, Single Arm Clinical Trial to Evaluate the Safety and Effectiveness of Flow Modulation Device for Intracranial Aneurysms
The purpose of this study is to assess safety and effectiveness of the p64/p48 MW HPC Flow Modulation Device.
Status | Recruiting |
Enrollment | 120 |
Est. completion date | June 30, 2026 |
Est. primary completion date | February 28, 2026 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 80 Years |
Eligibility | Inclusion Criteria: - Aged from 18 to 80 years, male or female; - Patients diagnosed as intracranial aneurysms by brain CTA/MRA/DSA; - Patients with unruptured saccular aneurysms or fusiform aneurysm who are clinically determined to use flow modulation device for endovascular treatment; - The diameter of the target aneurysm parent vessel was 1.75-5mm; - Patients target aneurysm is planned to be embolized using flow modulation devices only; - The mRS Score of the patients was 0-2 - Patients understand the purpose of the study, accept the follow-up period, and agree to comply with all requirements, agree to participate in the clinical trial and voluntarily sign the informed consent. Exclusion Criteria: - Patients who have contraindications to antiplatelet and/or anticoagulant therapy or do not start antiplatelet therapy in time before treatment; - Patients with anatomical structure is not suitable for endovascular treatment due to severe vascular tortuosity or stenosis shown by angiography; - Patients with acute ruptured aneurysm or with a history of intracranial hemorrhage or subarachnoid hemorrhage within 30 days before surgery; - Patients with target aneurysm treated with endovascular interventional therapy before enrollment; - Known to be allergic to Nitinol platinum alloy and angiographic agents; - Conditions that in the opinion of the investigators would prevent patients from completing the study, such as the expected survival period of active tumor less than 1-year, high-risk group of cerebral thrombosis, heart failure and atrial fibrillation; - The target aneurysms were blood vesicular aneurysms, pseudoaneurysms, or aneurysms associated with arteriovenous malformation, moyamoya disease, or multiple aneurysms that could not be treated by a single flow modulation device; - Serious infection is not controlled and is not suitable for operation; - Patients who underwent major surgery or interventional therapy (such as brain, cardiac, chest, abdominal or peripheral vascular) within 30 days before surgery; - Obvious abnormal coagulation function or bleeding tendency; - Combined with severe renal insufficiency, creatinine greater than or equal to 200umol/L; Patients with severe liver diseases (such as acute and chronic hepatitis, cirrhosis), or ALT more than 3 times the upper normal limit; - Pregnancy, lactation, or women of childbearing age who plan to be pregnant during the study period; - Participation in any other clinical trial within 30 days prior to signing informed consent; - Other conditions considered by the investigator to be inappropriate for enrollment. |
Country | Name | City | State |
---|---|---|---|
China | Xuanwu Hospital, Capital Medical University | Beijing |
Lead Sponsor | Collaborator |
---|---|
Shanghai Wallaby Medical Technologies Co.,Inc. | Phenox GmbH |
China,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Rate of complete occlusion | Raymond grade was evaluated by the independent imaging evaluation Committee 12 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated.
Aneurysm complete occlusion is defined as Raymond Grade I. |
12 months | |
Secondary | Technical success rate | Technical success is defined as the successful placement of a Flow Modulation Device. Successful implantation means that the Flow Modulation Device is placed at the target site and effectively covers the neck of the aneurysm, and the rest of the device is successfully released and withdrawn to the outside of the body. | Within 24 hours after surgery | |
Secondary | Rate of successful occlusion | Raymond grade was evaluated by the independent imaging evaluation Committee 6 months and 12 months after surgery according to the subjects' imaging results, and the rate of successful aneurysm occlusion was calculated.
Aneurysm successful occlusion is defined as Raymond Grade I/II. |
6 months, 12 months | |
Secondary | Rate of complete occlusion | Raymond grade was evaluated by the independent imaging evaluation Committee 6 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated.
Aneurysm complete occlusion is defined as Raymond Grade I. |
6 months | |
Secondary | Rate of good clinical prognosis | Good clinical prognosis means mRS 0~2 | 3 months, 6 months, 12 months | |
Secondary | Rate of in-stent-stenosis | In-stent-stenosis defined as moderate or severe stenosis of the tumor artery, that is, stenosis > 50% | to 6 months, to 12 months | |
Secondary | Device performance evaluation | After each use of the device, the researchers evaluated the operational performance of the device in terms of conveying, flexibility, compliance and wall adhesion. | Within 24 hours after surgery | |
Secondary | Death, stroke, and thrombotic events | Record the number of death, stroke and thrombotic events throughout the clinical trial period. | to 12 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04870047 -
Coating to Optimize Aneurysm Treatment In The New Flow Diverter Generation
|
N/A | |
Recruiting |
NCT05968053 -
Detection of Microplastics and Nanoplastics in Neurosurgery Patients (DT-MiNi)
|
||
Not yet recruiting |
NCT05665309 -
Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor
|
N/A | |
Completed |
NCT02783339 -
Neuroform Atlas Stent for Intracranial Aneurysm Treatment
|
||
Withdrawn |
NCT01194388 -
Axium Coil in Completing Endovascular Aneurysm Surgery Study
|
||
Completed |
NCT00071565 -
Familial Intracranial Aneurysm Study II
|
N/A | |
Recruiting |
NCT05409989 -
MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study
|
N/A | |
Completed |
NCT03680742 -
Contour Neurovascular System - European Pre-Market Unruptured Aneurysm
|
N/A | |
Completed |
NCT04872842 -
Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on 100 Regional Medical Centers in China and Population Follow-up Study
|
||
Terminated |
NCT02532517 -
Study to Evaluate the Safety and Effectiveness of the CODMAN ENTERPRISE® Vascular Reconstruction Device
|
N/A | |
Completed |
NCT03663257 -
Study to Evaluate Cerebral AneurysmFlow Results in Occlusion
|
||
Recruiting |
NCT06189950 -
Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms:REBRIDGE
|
N/A | |
Recruiting |
NCT05608122 -
Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on Regional Medical Centers in China and Population Follow-up Study (Phase Ⅱ)
|
||
Recruiting |
NCT03661463 -
Unruptured Intracranial Aneurysm Aspirin Trial (UIAAT).
|
Phase 2 | |
Completed |
NCT02609867 -
A Feasibility Study to Evaluate the Safety and Effectiveness of Implantation of Flowise Cerebral Flow Diverter (Flowise)
|
N/A | |
Active, not recruiting |
NCT02292017 -
Prospective Packing Density With Target Coils I
|
N/A | |
Active, not recruiting |
NCT01872741 -
Minipterional Versus Pterional Craniotomy
|
N/A | |
Completed |
NCT00993057 -
Efficiency of Two Glucose Sampling Protocols for Maintenance of Euglycemia
|
Early Phase 1 | |
Completed |
NCT00777088 -
Pipeline for Uncoilable or Failed Aneurysms
|
N/A | |
Completed |
NCT00777907 -
Complete Occlusion of Coilable Aneurysms
|
Phase 3 |