Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT06158750
Other study ID # TP-1312
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date November 17, 2023
Est. completion date June 30, 2026

Study information

Verified date November 2023
Source Shanghai Wallaby Medical Technologies Co.,Inc.
Contact Wenwen Jia
Phone +86 18818201005
Email Wendy.Jia@wallabyphenox.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to assess safety and effectiveness of the p64/p48 MW HPC Flow Modulation Device.


Description:

Title: A prospective, multicenter, single arm clinical trial to evaluate the safety and effectiveness of Flow Modulation Device for intracranial aneurysms. Device: p64/p48 MW HPC Flow Modulation Device. Study design: Prospective, multicenter, single arm Clinical Study. Purpose: To assess safety and effectiveness of p64/p48 MW HPC Flow Modulation Device . Study duration: 32 months. Sample Size: 120 patients. Number of sites: ≤10. Follow-up time: 12 months.


Recruitment information / eligibility

Status Recruiting
Enrollment 120
Est. completion date June 30, 2026
Est. primary completion date February 28, 2026
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria: - Aged from 18 to 80 years, male or female; - Patients diagnosed as intracranial aneurysms by brain CTA/MRA/DSA; - Patients with unruptured saccular aneurysms or fusiform aneurysm who are clinically determined to use flow modulation device for endovascular treatment; - The diameter of the target aneurysm parent vessel was 1.75-5mm; - Patients target aneurysm is planned to be embolized using flow modulation devices only; - The mRS Score of the patients was 0-2 - Patients understand the purpose of the study, accept the follow-up period, and agree to comply with all requirements, agree to participate in the clinical trial and voluntarily sign the informed consent. Exclusion Criteria: - Patients who have contraindications to antiplatelet and/or anticoagulant therapy or do not start antiplatelet therapy in time before treatment; - Patients with anatomical structure is not suitable for endovascular treatment due to severe vascular tortuosity or stenosis shown by angiography; - Patients with acute ruptured aneurysm or with a history of intracranial hemorrhage or subarachnoid hemorrhage within 30 days before surgery; - Patients with target aneurysm treated with endovascular interventional therapy before enrollment; - Known to be allergic to Nitinol platinum alloy and angiographic agents; - Conditions that in the opinion of the investigators would prevent patients from completing the study, such as the expected survival period of active tumor less than 1-year, high-risk group of cerebral thrombosis, heart failure and atrial fibrillation; - The target aneurysms were blood vesicular aneurysms, pseudoaneurysms, or aneurysms associated with arteriovenous malformation, moyamoya disease, or multiple aneurysms that could not be treated by a single flow modulation device; - Serious infection is not controlled and is not suitable for operation; - Patients who underwent major surgery or interventional therapy (such as brain, cardiac, chest, abdominal or peripheral vascular) within 30 days before surgery; - Obvious abnormal coagulation function or bleeding tendency; - Combined with severe renal insufficiency, creatinine greater than or equal to 200umol/L; Patients with severe liver diseases (such as acute and chronic hepatitis, cirrhosis), or ALT more than 3 times the upper normal limit; - Pregnancy, lactation, or women of childbearing age who plan to be pregnant during the study period; - Participation in any other clinical trial within 30 days prior to signing informed consent; - Other conditions considered by the investigator to be inappropriate for enrollment.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
p64/p48 MW HPC Flow Modulation Device
Endovascular intervention with p64/p48 MW HPC Flow Modulation Device was performed in patients diagnosed with intracranial aneurysms

Locations

Country Name City State
China Xuanwu Hospital, Capital Medical University Beijing

Sponsors (2)

Lead Sponsor Collaborator
Shanghai Wallaby Medical Technologies Co.,Inc. Phenox GmbH

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary Rate of complete occlusion Raymond grade was evaluated by the independent imaging evaluation Committee 12 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated.
Aneurysm complete occlusion is defined as Raymond Grade I.
12 months
Secondary Technical success rate Technical success is defined as the successful placement of a Flow Modulation Device. Successful implantation means that the Flow Modulation Device is placed at the target site and effectively covers the neck of the aneurysm, and the rest of the device is successfully released and withdrawn to the outside of the body. Within 24 hours after surgery
Secondary Rate of successful occlusion Raymond grade was evaluated by the independent imaging evaluation Committee 6 months and 12 months after surgery according to the subjects' imaging results, and the rate of successful aneurysm occlusion was calculated.
Aneurysm successful occlusion is defined as Raymond Grade I/II.
6 months, 12 months
Secondary Rate of complete occlusion Raymond grade was evaluated by the independent imaging evaluation Committee 6 months after surgery according to the subjects' imaging results, and the rate of complete aneurysm occlusion was calculated.
Aneurysm complete occlusion is defined as Raymond Grade I.
6 months
Secondary Rate of good clinical prognosis Good clinical prognosis means mRS 0~2 3 months, 6 months, 12 months
Secondary Rate of in-stent-stenosis In-stent-stenosis defined as moderate or severe stenosis of the tumor artery, that is, stenosis > 50% to 6 months, to 12 months
Secondary Device performance evaluation After each use of the device, the researchers evaluated the operational performance of the device in terms of conveying, flexibility, compliance and wall adhesion. Within 24 hours after surgery
Secondary Death, stroke, and thrombotic events Record the number of death, stroke and thrombotic events throughout the clinical trial period. to 12 months
See also
  Status Clinical Trial Phase
Recruiting NCT04870047 - Coating to Optimize Aneurysm Treatment In The New Flow Diverter Generation N/A
Recruiting NCT05968053 - Detection of Microplastics and Nanoplastics in Neurosurgery Patients (DT-MiNi)
Not yet recruiting NCT05665309 - Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor N/A
Completed NCT02783339 - Neuroform Atlas Stent for Intracranial Aneurysm Treatment
Withdrawn NCT01194388 - Axium Coil in Completing Endovascular Aneurysm Surgery Study
Completed NCT00071565 - Familial Intracranial Aneurysm Study II N/A
Recruiting NCT05409989 - MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval Study N/A
Completed NCT03680742 - Contour Neurovascular System - European Pre-Market Unruptured Aneurysm N/A
Completed NCT04872842 - Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on 100 Regional Medical Centers in China and Population Follow-up Study
Terminated NCT02532517 - Study to Evaluate the Safety and Effectiveness of the CODMAN ENTERPRISE® Vascular Reconstruction Device N/A
Completed NCT03663257 - Study to Evaluate Cerebral AneurysmFlow Results in Occlusion
Recruiting NCT06189950 - Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms:REBRIDGE N/A
Recruiting NCT05608122 - Establishment of Online Registration Platform for Unruptured Intracranial Aneurysms Based on Regional Medical Centers in China and Population Follow-up Study (Phase Ⅱ)
Recruiting NCT03661463 - Unruptured Intracranial Aneurysm Aspirin Trial (UIAAT). Phase 2
Completed NCT02609867 - A Feasibility Study to Evaluate the Safety and Effectiveness of Implantation of Flowise Cerebral Flow Diverter (Flowise) N/A
Active, not recruiting NCT02292017 - Prospective Packing Density With Target Coils I N/A
Active, not recruiting NCT01872741 - Minipterional Versus Pterional Craniotomy N/A
Completed NCT00993057 - Efficiency of Two Glucose Sampling Protocols for Maintenance of Euglycemia Early Phase 1
Completed NCT00777907 - Complete Occlusion of Coilable Aneurysms Phase 3
Completed NCT00777088 - Pipeline for Uncoilable or Failed Aneurysms N/A