Infertility Clinical Trial
Official title:
Manual Versus Automated Measurements of Ovarian Follicle Diameter in High Responding Patients With GnRH Agonist Triggering of Final Oocyte Maturation
Accurate follicular monitoring of Controlled Ovarian Stimulation by transvaginal ultrasound
is considered important for the success of human in vitro fertilization (IVF). The aim of
this study is to evaluate the effect of timing oocyte maturation and egg collection on the
basis of follicular measurements made automatically with Sono Automated Volume Calculation
(SonoAVC) against those made with conventional 2D ultrasound in relation to the number of
mature oocytes collected.
This study will take place in women undergoing IVF who are high responders (>=14
follicles>=11mm) and hence at risk for developing ovarian hyperstimulation syndrome (OHSS),
treated with a GnRH antagonist protocol and administered GnRH agonist to trigger final oocyte
maturation.
Accurate follicular monitoring of Controlled Ovarian Stimulation by transvaginal ultrasound
is considered important for the success of human in vitro fertilization (IVF). Accurate
assessment of the size of follicles is important for the timing of oocyte maturation and
subsequent oocyte retrieval.
Serial assessment of follicle number and size is used routinely to assess the response to
ovarian stimulation during assisted reproduction treatment (ART). Two-dimensional (2D)
ultrasound is used to identify and scroll through each ovary while the observer quantifies
the number of follicles present. An objective assessment of the size of the larger follicles,
commonly those measuring >10 mm, is then made through a series of 2D measurements of their
perceived mean diameter.
Sono Automated Volume Calculation (SonoAVC; GE Medical Systems) is a new software program
that can be applied to datasets acquired with use of threedimensional (3D) ultrasound. It
individually identifies and quantifies the size of any hypoechoic region within these 3D
datasets, providing an automatic estimation of their absolute dimensions and volume. SonoAVC
is an ideal and, potentially, a clinically important tool for the assessment and measurement
of follicles during controlled ovarian stimulation because each hypoechoic area is
individually color coded, thereby eliminating the possibility of measuring the same follicle
more than once.
In women with high ovarian response to gonadotrophin stimulation, the accurate measurement of
the number and size of follicles present in hyperstimulated ovaries is a challenge for
clinicians and ultrasonographers.
The aim of this study is to evaluate the effect of timing final oocyte maturation trigger and
egg collection on the basis of follicular measurements made automatically with SonoAVC
against those made with conventional 2D ultrasound in relation to the number of mature
oocytes collected. This study will include women undergoing ART who are high responders
(presence of =>14 follicles>=11mm) and hence at risk for developing ovarian hyperstimulation
syndrome (OHSS), treated with a GnRH antagonist protocol and are administered GnRH agonist to
trigger final oocyte maturation. All resulting embryos (blastocysts) will be cryopreserved
and transferred in a subsequent frozen cycle.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03607409 -
Role of Inhibin A as Biomarker for Ovarian Response for IVF Treatment
|
||
Recruiting |
NCT02312076 -
GnRHa for Luteal Phase Support in Long GnRHa Protocol Cycles
|
Phase 4 | |
Terminated |
NCT02161861 -
Improvement of IVF Fertilization Rates, by the Cyclic Tripeptide FEE - Prospective Randomized Study
|
N/A | |
Completed |
NCT03287479 -
Comparison of a Semi-automated Closed Vitrification System (Gavi®) With a Manual Open Vitrification Sytem (Cryotop®)
|
N/A | |
Terminated |
NCT03522350 -
Randomized Trial Comparing EmbryoScope With EmbryoScope+.
|
N/A | |
Completed |
NCT04496284 -
Embryo Transfer Outcomes After Vitrification With Slush Nitrogen Compared to Liquid Nitrogen
|
N/A | |
Completed |
NCT03623659 -
pArtiaL zonA pelluciDa Removal by assisteD hatchINg of Blastocysts
|
N/A | |
Completed |
NCT03895099 -
New Ovarian Stimulation With Random Start, Use of Progestin Protocol for Oocyte Donors
|
Phase 3 | |
Active, not recruiting |
NCT04142112 -
Randomized, Standard-Controlled, Study to Evaluate the Ohana IVF Sperm Preparation Kit, SPeRtility IVF Next Generation
|
N/A | |
Completed |
NCT03152643 -
Cumulative Live Birth Rates After Cleavage-stage Versus Blastocyst-stage Embryo Transfer
|
N/A | |
Recruiting |
NCT03683771 -
Assessment of Endometrial Pattern and Sub-endometrial Vascularity in ICSI Outcome
|
||
Recruiting |
NCT03161119 -
Comparing Two Different Embryo Transfer Catheters
|
N/A | |
Completed |
NCT04108039 -
Micronized Progesterone vs Gonadotropin-releasing Hormone (GnRH) Antagonist in Freeze-all IVF Cycles.
|
N/A | |
Completed |
NCT03678818 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Latrunculin A (ICSI-LA)
|
N/A | |
Completed |
NCT03677492 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Cytochalasin D ( ICSI-CD)
|
N/A | |
Completed |
NCT03678597 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Latrunculin B ( ICSI-LB)
|
N/A | |
Completed |
NCT03678571 -
Oocyte Vitrification Aided With Latrunculin A
|
N/A | |
Completed |
NCT03678584 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Chaetoglobosin A ( ICSI-CA)
|
N/A | |
Completed |
NCT03678610 -
Handling Medium for ICSI With Ionomycin and Latrunculin A
|
N/A | |
Completed |
NCT03678558 -
Oocyte Vitrification Aided With Cytochalasin B
|
N/A |