A Randomized Single-blind Comparison of Two Embryo Transfer Catheters in Patients Undergoing in Vitro Fertilization and Embryo Transfer
In-vitro fertilization (IVF) treatment involves development of multiple follicles following ovarian stimulation, oocyte retrieval and embryo transfer (ET). ET is the final and most crucial step of IVF treatment. The ET catheter has to pass through the endocervical canal to go into the uterine cavity through the internal os. The endocervical canal may be filled up with mucus or blood. Embryos trapped in the mucus or blood after the passage of the endocervical canal may not be able to implant into the endometrium. Guardia™ Pro Protective ET catheter is designed to allow the safe passage of embryos through cervical mucus and blood as its outer sheath protects the embryo through entry and then opens in petals to further advance the inner catheter and gently place the embryo. The hypothesis of this study is that the pregnancy rate is significantly higher after ET using protective ET catheters.
In-vitro fertilization (IVF) treatment involves development of multiple follicles following ovarian stimulation, oocyte retrieval and embryo transfer (ET). Despite recent advances in ovarian stimulation, the method of assisted fertilization and improved culture conditions, the implantation potential of embryos remains around 20-25% for a long time. ET is the final and most crucial step of IVF treatment and pregnancy rates after ET may be affected by various factors. In a Cochrane meta-analysis (Derks et al., 2009), no evidence of a benefit was found for performing ET with a full bladder, the removal of cervical mucus, and flushing the endocervical canal or the endometrial cavity. No data were found on changing the woman's position, the use of a tenaculum, the performance of a dummy transfer, and embryo afterloading. Other meta-analyses demonstrate that the use of soft ET catheters (Buckett, 2008) and transabdominal ultrasound guidance (Brown et al., 2010) lead to a higher chance of clinical pregnancy when compared with the use of stiff catheters and clinical touch respectively. The ET catheter has to pass through the endocervical canal to go into the uterine cavity through the internal os. The endocervical canal may be filled up with mucus or blood. Embryos trapped in the mucus or blood after the passage of the endocervical canal may not be able to implant into the endometrium. Guardia™ Pro Protective ET catheter is designed to allow the safe passage of embryos through cervical mucus and blood as its outer sheath protects the embryo through entry and then opens in petals to further advance the inner catheter and gently place the embryo. There is still no study comparing conventional and protective ET catheters in terms of the pregnancy rate of IVF treatment. The hypothesis of this study is that the pregnancy rate is significantly higher after ET using protective ET catheters. Research plan Patients attending the Department for IVF-ET will be recruited if they fulfill the inclusion criteria and do not have the exclusion criteria. The FET treatment will be arranged as indicated. On the day of ET, patients will be randomized according to a computer-generated randomization list in sealed envelopes into two groups: conventional and protective ET catheter groups. Conventional ET catheters will be used in the conventional ET catheter group while protective ET catheters will be used in the protective ET catheter group. Patients would be blinded to the group assigned although the clinical, nursing and laboratory staff will be aware of the type of catheters used. A maximum of two good quality embryos are to be replaced. Patients are asked to keep a mildly full bladder so that the uterus can be visualized by abdominal sonogram during the procedure. A bivalve speculum is inserted into the vagina and the cervix is cleaned with warm saline and culture medium. The axis, degree of flexion and the configuration of the uterine cavity are determined by transabdominal ultrasound examination before the transfer. Under transabdominal ultrasound guidance, the outer catheter is inserted into the cervical canal 4 cm from the external os, with the tip just beyond the internal os. A malleable obturator is used if difficulty is encountered. The inner transfer catheter with the loaded embryo(s) is then inserted into the uterine cavity via the outer cannula. The aim is to put the tip of the inner catheter inside the uterine cavity 6 cm from the external os and care was taken not to advance the tip beyond 1 cm from the uterine fundus. The transfer volume is gently expelled by the technician. The catheters will be held in place for 30 seconds. Both the inner and outer catheters will be checked by the technician under the microscope to make sure that the embryos have been replaced. The luteal phase support will be used if needed and antenatal management is as usual, if pregnant. Sample size estimation The ongoing pregnancy rate of IVF-ET in 2010 was about 30.0%. Assuming a 10% increase following use of protective ET catheters as significant, 356 patients in each arm was required at a power of 80% and a significance level of 5% (Sigmastat, Jandel Scientific, San Rafael, CA, USA). A total of 720 patients will be recruited into the study. Interim analysis will be performed after recruitment of every 100 subjects. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03607409 -
Role of Inhibin A as Biomarker for Ovarian Response for IVF Treatment
|
||
Recruiting |
NCT02312076 -
GnRHa for Luteal Phase Support in Long GnRHa Protocol Cycles
|
Phase 4 | |
Terminated |
NCT02161861 -
Improvement of IVF Fertilization Rates, by the Cyclic Tripeptide FEE - Prospective Randomized Study
|
N/A | |
Completed |
NCT03287479 -
Comparison of a Semi-automated Closed Vitrification System (Gavi®) With a Manual Open Vitrification Sytem (Cryotop®)
|
N/A | |
Terminated |
NCT03522350 -
Randomized Trial Comparing EmbryoScope With EmbryoScope+.
|
N/A | |
Completed |
NCT04496284 -
Embryo Transfer Outcomes After Vitrification With Slush Nitrogen Compared to Liquid Nitrogen
|
N/A | |
Completed |
NCT03623659 -
pArtiaL zonA pelluciDa Removal by assisteD hatchINg of Blastocysts
|
N/A | |
Completed |
NCT03895099 -
New Ovarian Stimulation With Random Start, Use of Progestin Protocol for Oocyte Donors
|
Phase 3 | |
Active, not recruiting |
NCT04142112 -
Randomized, Standard-Controlled, Study to Evaluate the Ohana IVF Sperm Preparation Kit, SPeRtility IVF Next Generation
|
N/A | |
Completed |
NCT03152643 -
Cumulative Live Birth Rates After Cleavage-stage Versus Blastocyst-stage Embryo Transfer
|
N/A | |
Recruiting |
NCT03683771 -
Assessment of Endometrial Pattern and Sub-endometrial Vascularity in ICSI Outcome
|
||
Recruiting |
NCT03161119 -
Comparing Two Different Embryo Transfer Catheters
|
N/A | |
Completed |
NCT04108039 -
Micronized Progesterone vs Gonadotropin-releasing Hormone (GnRH) Antagonist in Freeze-all IVF Cycles.
|
N/A | |
Completed |
NCT03678571 -
Oocyte Vitrification Aided With Latrunculin A
|
N/A | |
Completed |
NCT03678818 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Latrunculin A (ICSI-LA)
|
N/A | |
Completed |
NCT03678610 -
Handling Medium for ICSI With Ionomycin and Latrunculin A
|
N/A | |
Completed |
NCT03678584 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Chaetoglobosin A ( ICSI-CA)
|
N/A | |
Completed |
NCT03677492 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Cytochalasin D ( ICSI-CD)
|
N/A | |
Completed |
NCT03678558 -
Oocyte Vitrification Aided With Cytochalasin B
|
N/A | |
Completed |
NCT03678597 -
Supplementing Intracytoplasmic Sperm Injection Handling Medium With Latrunculin B ( ICSI-LB)
|
N/A |