Hypertension Clinical Trial
Official title:
Target Organ Damage and Blood Pressure, Retinal Vessels, Oxidative Stress and Polymorphisms Vav-2 and Vav-3 in Hypertensive Subjects (LOD-Hypertension)
Objectives: To analyze the influence on the presence of target organ damage renal, cardiac
and vascular of peripheral and central blood pressure, retinal vessels caliber, oxidative
stress and polymorphisms of genes VAV-2-3 in hypertensive subjects.
Methodology: A cross- sectional design we will performed . Population: 486 hypertensive
patients. Target organ damage will be assessed by tests recommended in 2013 European
guidelines of hypertension. Blood pressure office and ambulatory, retinal caliber
vassels,oxidative stress and polymorphisms VAL -2-3 will be measurement.
Ambulatory blood pressure monitoring (ABPM): The ABPM will be performed on a day of standard
activity, with an adequate cuff for the size of the patient's arm. A control system,
SpaceLabs 90207 model (Spacelabs Healthcare, Issaquah, Washington, USA), validated according
to the protocol of the British Hypertension Society, will be used [57]. The records in which
the percentage of valid readings will be 80% of the total and with valid readings at all
times were considered to be valid. Furthermore, for the records to be evaluable, at least 14
measurements will be required during the daytime period, or at least seven during the
nightime or rest period. The monitor will be scheduled for obtaining blood pressure
measurements every 20 min during the daytime period and every 30 min during the rest period.
The average and dispersion estimators of SBP and DBP were calculated during the 24-h,
daytime and nightime periods, defined based on the diary reported by the patient. The
patient completes a form specifying bedtime and wake-up time.
Ambulatory arterial stiffness index (AASI) and Home arterial stiffness index (HASI):
Arterial stiffness will be evaluated by the ambulatory and home arterial stiffness indices
(AASI and HASI). For AASI and HASI estimation, the regression slope of diastolic on systolic
blood pressure will be computed for each individual on the basis of 24-hour ABPM (AASI) and
also HASI readings over 6 days. AASI as well as HASI were defined as one minus the
respective regression slope of DBP on SBP [58]. AASI will also computed from waking or
sleeping blood pressure.
Evaluation of retinal vessels: Retinography will be performed using a Topcon TRC NW 200
nonmydriatic retinal camera (Topcon Europe B.C., Capelle a/d Ijssel, The Netherlands),
obtaining nasal and temporal images centered on the disk. The nasal image with the centered
disk will be loaded into the developed software, AV Index calculator (Ciclorisk SL,
Salamanca, Spain, registry no. 00/2011/589). The software automatically recognizes the disk
and draws two external concentric circles which delimit area A, between 0 and 0.5 disk
diameters from the optic disk margin, and area B, between 0.5 and 1 disk diameters from the
margin. The software first identifies the limits of the different vessels, after which it
automatically recognizes arteries and veins, and makes multiple measurements of the diameter
of the section of the vessels circulating through area B. It finally estimates the mean
caliber of veins and arteries in mm, and these measurements are summarized as an
arteriole-venule ratio, AVIx. An AVIx of 1.0 suggests that arteriolar diameters will be on
average the same as venular diameters in that eye, whereas a smaller AVR suggests narrower
arterioles. We used the pairs of main vessels in the upper and lower temporal quadrants,
rejecting all other vessels, to improve reliability and increase efficiency of the process,
analyzing measures for each quadrant separately and together to estimate the mean measure in
each eye. [64].
Laboratory:Determining the concentration of superoxide and catecholamines (adrenaline and
noradrenaline) in plasma and urine anion will be determined by ELISA (CatCombi ELISA, IBL,
Deventer, The Netherlands), following the manufacturers instructions. Superoxide dismutase
activity in plasma will be also assessed using ELISA kits (Cu-Zn superoxid-dismutase ELISA,
IBL), and the urinary excretion and plasma levels of lipid peroxides by measuring products
react with thiobarbituric acid (TBARS) (OxiSelect TBARS Assay Kit, Cell Biolabs, Inc., San
Diego, CA 92126).
In a sample of DNA from peripheral blood erythrocyte polymorphisms of VAV and VAV-2-3 genes
in all study subjects are studied. To this end, 10cc of venous blood obtained with
anticoagulant (EDTA: ethylene diamine tetra-acetic acid).
Renal assessment: The kidney damage will be assessed by measuring creatinine plasma
concentration, the glomerular filtration rate was estimated by CKD-EPI (Chronic Kidney
Disease Epidemiology Collaboration) [59] and the MDRD-IDMS (Modification of Diet in Renal
Disease-Isotopic Dilution Mass Spectrometry) [60] equation and proteinuria were assessed by
the albumin/creatinine ratio following the 2007 European Society of Hypertension/European
Society of Cardiology Guidelines criteria [2]. Subclinical organ damage was defined as
plasma creatinine between 1.3 - 1.5 mg/dl in men and 1.2 - 1.4 mg/dl in women, glomerular
filtration rate below 60 ml/min or albumin/creatinine ratio > 22 mg/gr in men and 31 mg/ gr
in women. Renal disease was defined as plasma creatinine of 1.5 mg/dl or higher in men and
1.4 mg/l in women or albumin/creatinine ratio > 300 mg/24 h.
Cardiac assessment: The electrocardiographic examination will be performed with a General
Electric MAC 3.500 ECG System (Niskayuna, New York, USA), that measures automatically the
voltage and duration of waves and estimates the criteria of the Cornell voltage-duration
product (Cornell VDP) [61] to assess the LVH by the following equation: Men ((RaVL + SV3) *
QRS) and women ((RaVL + SV3) * QRS + 6). LVH will be defined as the voltage-duration product
> 2,440 mm/ms [2] and Sokolow and R avl > 11.
Pulse wave velocity (PWV): These parameters will be estimated using the SphygmoCor System
(AtCor Medical Pty Ltd., Head Office, West Ryde, Australia). Using the SphygmoCor System (Vx
pulse wave velocity), and with the patient in the supine position, the pulse waves of the
carotid and femoral arteries were analyzed, estimating the delay with respect to the ECG
wave and calculating PWV. Distance measurements were taken with a measuring tape from the
sternal notch to the carotid and femoral arteries at the sensor location [62].
Assessment of vascular structure by carotid intima media thickness (IMT): Carotid ultrasound
to assess C-IMT will be performed by two investigators trained for this purpose before
starting the study. The reliability of such recordings was evaluated before the study, using
the intraclass correlation coefficient, which showed values of 0.97 (95%CI: 0.94-0.99) for
intra-observer agreement on repeated measurements in 20 subjects, and 0.90 (95%CI:
0.74-0.96) for inter-observer agreement. According to the Bland-Altman analysis, the limit
of inter-observer agreement was 0.02 (95% CI: −0.05-0.10), while the limit of intra-observer
agreement was 0.01 (95% CI: −0.03-0.06). A Sonosite Micromax ultrasound device paired with a
5-10 MHz multi-frequency high-resolution linear transducer with Sonocal software will be
used for performing automatic measurements of carotid IMT in order to optimize
reproducibility. Measurements will be made of the common carotid after the examination of a
10-mm longitudinal section at a distance of 1 cm from the bifurcation, performing
measurements in the anterior or proximal wall, and in the posterior or distal wall in the
lateral, anterior and posterior projections, following an axis perpendicular to the artery
to discriminate two lines: one for the intima-blood interface and the other for the
media-adventitious interface. A total of 6 measurements will be obtained of the right
carotid, with another 6 measurements of the left carotid, using average values (average
carotid IMT) and maximum values (maximum carotid IMT) automatically calculated by the
software [63]. The measurements will be obtained with the subject lying down, with the head
extended and slightly turned opposite to the examined carotid artery. The average IMT will
considered abnormal if it measured 0.90 mm, or if there will be atherosclerotic plaques with
a diameter of 1.5 mm or a focal increase of 0.5 mm or 50% of the adjacent IMT [2].
;
Observational Model: Cohort, Time Perspective: Cross-Sectional
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Terminated |
NCT04591808 -
Efficacy and Safety of Atorvastatin + Perindopril Fixed-Dose Combination S05167 in Adult Patients With Arterial Hypertension and Dyslipidemia
|
Phase 3 | |
| Recruiting |
NCT04515303 -
Digital Intervention Participation in DASH
|
||
| Completed |
NCT05433233 -
Effects of Lifestyle Walking on Blood Pressure in Older Adults With Hypertension
|
N/A | |
| Completed |
NCT05491642 -
A Study in Male and Female Participants (After Menopause) With Mild to Moderate High Blood Pressure to Learn How Safe the Study Treatment BAY3283142 is, How it Affects the Body and How it Moves Into, Through and Out of the Body After Taking Single and Multiple Doses
|
Phase 1 | |
| Completed |
NCT03093532 -
A Hypertension Emergency Department Intervention Aimed at Decreasing Disparities
|
N/A | |
| Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
| Completed |
NCT05529147 -
The Effects of Medication Induced Blood Pressure Reduction on Cerebral Hemodynamics in Hypertensive Frail Elderly
|
||
| Recruiting |
NCT06363097 -
Urinary Uromodulin, Dietary Sodium Intake and Ambulatory Blood Pressure in Patients With Chronic Kidney Disease
|
||
| Recruiting |
NCT05976230 -
Special Drug Use Surveillance of Entresto Tablets (Hypertension)
|
||
| Completed |
NCT06008015 -
A Study to Evaluate the Pharmacokinetics and the Safety After Administration of "BR1015" and Co-administration of "BR1015-1" and "BR1015-2" Under Fed Conditions in Healthy Volunteers
|
Phase 1 | |
| Completed |
NCT05387174 -
Nursing Intervention in Two Risk Factors of the Metabolic Syndrome and Quality of Life in the Climacteric Period
|
N/A | |
| Completed |
NCT04082585 -
Total Health Improvement Program Research Project
|
||
| Recruiting |
NCT05121337 -
Groceries for Black Residents of Boston to Stop Hypertension Among Adults Without Treated Hypertension
|
N/A | |
| Withdrawn |
NCT04922424 -
Mechanisms and Interventions to Address Cardiovascular Risk of Gender-affirming Hormone Therapy in Trans Men
|
Phase 1 | |
| Active, not recruiting |
NCT05062161 -
Sleep Duration and Blood Pressure During Sleep
|
N/A | |
| Completed |
NCT05087290 -
LOnger-term Effects of COVID-19 INfection on Blood Vessels And Blood pRessure (LOCHINVAR)
|
||
| Not yet recruiting |
NCT05038774 -
Educational Intervention for Hypertension Management
|
N/A | |
| Completed |
NCT05621694 -
Exploring Oxytocin Response to Meditative Movement
|
N/A | |
| Completed |
NCT05688917 -
Green Coffee Effect on Metabolic Syndrome
|
N/A | |
| Recruiting |
NCT05575453 -
OPTIMA-BP: Empowering PaTients in MAnaging Blood Pressure
|
N/A |