View clinical trials related to Heart Septal Defects.
Filter by:This is a randomized, double-blind, placebo controlled, multicenter study to compare the efficacy and safety of L-citrulline versus placebo in patients undergoing surgery for congenital heart defects. Eligible patients undergoing repair of a large unrestrictive ventricular septal defect (VSD), a partial or complete atrioventricular septal defect (AVSD), or an ostium primum atrial septal defect (primum ASD) will be eligible for enrollment.
In this study; Changes in appetite, hormones and growth of ventricular septal defect patients treated with non-surgical method were evaluated.
STITCH - Prospective Multi-Center Comparative Parallel Concurrent Study of the NobleStitch™ EL versus FDA approved Amplatzer Occluder device for closure of Patent Foramen Ovale to prevent recurrent ischemic stroke.
In this study; we evaluated the heart rate variability parameters of pediatric patients whose VSDs were closed with the transcatheter method before and after, and compared with the control group.
Establish a cardiovascular biomarker profile to help screening for congenital heart disease in infants and children as well as use non-invasive cardiac imaging in combination with such profiling to better predict the need for future cardiac interventions such as open heart surgery or cardiac catheter intervention selected types of with congenital heart disease.
Evaluation of the safety and efficacy of the reSept ASD Occluder to treat patients with clinically significant secundum atrial septal defect
The objectives of the study are: - To determine the efficacy of the Figulla Flex II device compared with that of the Amplatzer ASO device for transcatheter closure of secundum atrial septal defects - To determine the safety of the Figulla Flex II device compared with that of the Amplatzer ASO device for transcatheter closure of secundum atrial septal defects This is a randomized, controlled, multi-centre trial of the efficacy and safety of the Occlutech septal occluder (Figulla Flex II) compared to the AGA septal occluder (Amplatzer ASO) for transcatheter closure of secundum atrial septal defects in patients.
This clinical trial is studying the use of different levels of oxygen exposure during and after cardiopulmonary bypass in eligible infants to learn about its safety during heart surgery. In addition to having the various doses of oxygen, participants will also have blood samples, ultrasounds of the head, and brain wave patterns monitored. The hypotheses of this trial are: - that there will be no difference with regards to adverse events between the infants in the normoxia group compared to the infants in the standard of care group - there will be a significant difference in the measured partial pressure of oxygen (PaO2) values between the two treatment groups. - the use of normoxia during cardiopulmonary bypass and in the immediate post-operative period will result in clinically significant decrease in oxidative stress as measured by thiobarbituric acid reactive substances (TBARS) after cardiac surgery
A single-arm, non-randomized, multi-center clinical study of the Amplatzer™ Trevisio™ Intravascular Delivery System for facilitating percutaneous, transcatheter implantation of the Amplatzer™ Occluder Devices. NOTE: The enrollment for the VSD cohort is still recruiting (3 subjects at this moment); therefore, the overall status of the study is Recruiting.
This is an open-label, randomized, controlled trial of iatrogenic atrial septal defect closure with the an atrial septal occluder versus usual care observation in patients post-mitral valve intervention requiring large bore transspetal access.