View clinical trials related to Heart Septal Defects.
Filter by:The aim of the present study is to compare between general anesthesia versus sedation with dexmedetomidine and ketamine with local infilteration at the catheter insertion site in pediatric patients undergoing transcutaneous closure of atrial septal defect on hemodynamic changes.
The goal of this observational study is to evaluate the effectiveness and safety of vibro-acoustic pulmonary therapy (VAPT) in complex therapy for the acute respiratory failure of mixed type I-II stages in comparison with percussion massage in cardiac surgical patients in the early postoperative period.
Currently, research on the effect of thiamine administration during transcatheter closure on the structure and function of the left ventricle by examining levels of matrix metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 in children with left to right shunt congenital heart disease has never been carried out in Indonesia, so it is necessary carried out this research. This research was carried out by administering 100 mg of thiamine once per day to patients post transcatheter closure for 28 days. The parameters assessed were MMP-9, TIMP-1, and echocardiography to assess the structure and function of the left ventricle in CHD patients with left to right shunt lesions.
Introduction: The presence of pulmonary hypertension (PH) in atrial septal defect (ASD) poses a clinical challenge on whether or not to close the defect. Closing the defect increases the risk of low cardiac output syndrome (LCOS), while leaving the defect open may eventually lead to irreparable shunt reversal, hypoxemia, and death. The implementation of a fenestrated patch may halt LCOS while adding volume to the left heart. Methods: this is an analytical observational study involving patients with ostium secundum defect with PH who were operated on in Dr. Soetomo Hospital between January 2017 and October 2021. The aim of this study is to evaluate the improvement in left ventricular size during both systole and diastole.
The objective of this post-market registry is to assess the clinical use of the Lifetech CeraFlex™ Closure System in a real-world and on-label fashion.
The purpose of this study is to evaluate pain control following pediatric cardiac surgery with the use of local anesthesia via an ultrasound guided regional anesthetic technique compared with surgeon delivered wound infiltration.
The current study is designed to compare the perioperative analgesic efficacy of Erector spinae plane block (ESPB) and Pecto-intercostal-fascial plane block (PIFB) in adults undergoing cardiac surgery via median sternotomy. The primary outcome measure will be the analgesic effectiveness of both blocks in median sternotomy pain, while the secondary outcome measures will be time to extubation, and length of intensive care unit stay.
A multicenter, randomized, parallel-controlled clinical trial to evaluate the efficacy and safety of a new atrial septal defect occluder, ReAces®, and delivery system for the treatment of atrial septal defect occlusion. Compared with the traditional atrial septal occluder, this new atrial septal occluder supports re-puncture after occluder implantation. Thus those patients who have undergone atrial septal defect closure with the novel device may be eligible for future radiofrequency ablation of atrial fibrillation or mitral valve intervention. The trial is expected to enroll 128 patients who will be randomly assigned to the test group or control group in a 1:1 ratio. Patients in test group will received ReAces occluder,and the others the regular occluder.The experiment is scheduled to enroll 128 patients who will be randomly allocated to one of two groups: test or control. Patients in the test group will receive a ReAces occluder, while those in the control group will receive a standard occluder.The safety and efficacy of the two groups at 1 year after surgery will be compared.
The Occlutech® mVSD is indicated for percutaneous, transcatheter muscular ventricular septal defect closure device designed for the occlusion of hemodynamically significant muscular ventricular septal defects. The objectives of the study are: - To confirm the efficacy of Occlutech mVSD in patients requiring transcatheter occlusion (closure) of muscular ventricular septal defects. - To confirm the safety of Occlutech mVSD in patients requiring transcatheter occlusion (closure) of muscular ventricular septal defects.
The aim of this study is to compare Safety, efiicacy and clinical effects of surgical versus transcatheter closure of ventricular septal defect (VSD ). The outcome of interest is success rate, residual shunts, effect on tricuspid and aortic valves, need for blood transfusion, length of hospital and intensive care unit ( ICU ) stay, complications especially complete heart block, affection of kidney functions due to the procedure length caused by Cardiopulmonary bypass in case of surgical group or by the dye used in the group of transcatheter closure.