Heart Failure Clinical Trial
Official title:
Restoration of Atrioventricular Coupling by Cardiac Resynchronization Therapy in Heart Failure Patients With Prolonged PR Interval
Rationale: Prolongation of the electrocardiographic PR interval (PR interval > 200ms; also
known as first-degree atrioventricular block) is frequently encountered in clinical practice
and is generally considered as a benign sign. However, there is increasing evidence that a
prolonged PR interval results in poor hemodynamic performance with elevated left ventricular
(LV) end-diastolic pressures evidenced by diastolic mitral regurgitation. Previous studies
have also associated a prolonged PR interval with a substantially increased risk of future
atrial fibrillation (AF) and pacemaker-implantation, and increased risk of heart failure (HF)
hospitalization and death. These risks stress the importance of proper atrioventricular (AV)
coupling. Shortening of the PR interval may be especially important in heart failure patients
and can be obtained by atrioventricular pacing. A possible adverse effect of ventricular
pacing is that it results in ventricular dyssynchrony which may lead to worsening cardiac
function. This effect may be prevented by applying atrio-biventricular pacing. Data from
several previous (sub)studies have suggested this.
Objective: The purpose of this study is to investigate the acute hemodynamic effects of
restoration of atrioventricular coupling by atrio-biventricular pacing in patients with heart
failure and prolonged PR interval.
Study design: This study will be a multi-center, exploratory, prospective interventional,
nonrandomized acute hemodynamic study, using patients as their own controls.
Study population: The study will enroll 26 patients with symptomatic heart failure, reduced
left ventricular ejection fraction (LVEF) (< 35%) and prolonged PR interval (>230ms), but
without seriously prolonged QRS duration (<150ms) or left bundle branch block (LBBB) QRS
pattern, who are candidates for an implantable cardioverter defibrillator (ICD) device
according to current guidelines.
Main study parameters/endpoints: The main study parameter will be the acute hemodynamic
change in left ventricular stroke work (SW) during atrioventricular optimization by
atrio-biventricular pacing. Secondary parameters will be the acute hemodynamic changes in
left ventricular dP/dt|max and left ventricular stroke volume (SV) by invasive measurements
and in left ventricular stroke volume, diastolic mitral regurgitation and left ventricular
diastolic filling time by echocardiography during atrioventricular optimization by
atrio-biventricular pacing.
Nature and extent of the burden and risks associated with participation, benefit and group
relatedness: The patients are candidates for an ICD device in whom cardiac resynchronization
therapy (CRT) can be considered according to current guidelines. Patients in the present
study will receive a CRT-defibrillator (CRT-D). The risk and/or complications of the CRT-D
implantation are not additional for this study. After the implantation, acute invasive
hemodynamic measurements will be performed with a pressure-volume catheter, which is inserted
via the femoral artery and adds approximately 30 minutes to the standard procedure. An extra
radiation dose of approximately 50mGy is needed to place the pressure volume catheter in the
LV cavity. Local vascular complications of femoral artery puncture like bleeding or damage to
the vessel wall may occur but are rare. The non-invasive echocardiographic protocol one to
two weeks after implantation will add approximately 45 minutes to the routine outpatient
clinic visit. The patients do not have to visit the clinic outside the routine outpatient
clinic visits before and after a CRT-D implantation. The patients will have the potential
direct benefit from the procedure, by finding the patient's specific optimal
(atrioventricular) settings and thereby reducing above described risks of a prolonged PR
interval. In case of a worse hemodynamic performance due to the procedure, the CRT-D will be
programmed to back up pacing and there is no harm for the patient outside the above
subscribed extra measurements.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05196659 -
Collaborative Quality Improvement (C-QIP) Study
|
N/A | |
Recruiting |
NCT05650307 -
CV Imaging of Metabolic Interventions
|
||
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Active, not recruiting |
NCT05896904 -
Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction
|
N/A | |
Completed |
NCT05077293 -
Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
|
||
Recruiting |
NCT05631275 -
The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
|
||
Enrolling by invitation |
NCT05564572 -
Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology
|
N/A | |
Enrolling by invitation |
NCT05009706 -
Self-care in Older Frail Persons With Heart Failure Intervention
|
N/A | |
Recruiting |
NCT04177199 -
What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
|
||
Terminated |
NCT03615469 -
Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY)
|
N/A | |
Recruiting |
NCT06340048 -
Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure
|
Phase 1/Phase 2 | |
Recruiting |
NCT05679713 -
Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
|
||
Completed |
NCT04254328 -
The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure
|
N/A | |
Completed |
NCT03549169 -
Decision Making for the Management the Symptoms in Adults of Heart Failure
|
N/A | |
Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
Enrolling by invitation |
NCT05538611 -
Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
|
||
Recruiting |
NCT04262830 -
Cancer Therapy Effects on the Heart
|
||
Completed |
NCT06026683 -
Conduction System Stimulation to Avoid Left Ventricle Dysfunction
|
N/A | |
Withdrawn |
NCT03091998 -
Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support
|
Phase 1 | |
Recruiting |
NCT05564689 -
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
|