Clinical Trials Logo

Clinical Trial Summary

The purpose of the study is to determine the safety, and feasibility of a device, which enables LV volume and radius reduction through scar exclusion in patients whose systolic HF is due to ischemic cardiomyopathy. Appropriate subjects will have akinetic or dyskinetic scar located in the antero-septal LV distribution. Use of this device replicates the geometric reconfiguration of the ventricle achieved through surgical Left Ventricular Reconstruction (LVR), but on a beating, unsupported heart, thereby creating the option of avoiding the use of cardiopulmonary bypass pump (CBP).


Clinical Trial Description

Congestive heart failure is the "epidemic" of cardiovascular disease (Eugene Braunwald, NEJM 1997), yet there is no cure. The American Heart Association (AHA) reports the nearly five million Americans are afflicted. Approximately 1.5 million admissions in the US are due to heart failure (HF); it is the number one cost-item for Medicare, comprising 6% of its total expenditures. In view of the limitations of existing therapy, physicians have sought alternative treatments. In this regard, there has been longstanding interest in surgical reconstruction of the failing heart. The underlying premise has been to surgically reduce the size of the ventricular chamber by removing a portion of the ventricular wall to decrease chamber radius. A reduction of chamber radius reduces wall stress for a given pressure so that the remaining muscle is put into a more favorable mechanical state. The BioVentrix PliCath HF System consists of implantable anchors, the delivery system, and accessories, which are sterile and biocompatible. These devices are used in the reconfiguration of the abnormal cardiac geometry that is causing dysfunction by excluding a portion of the left ventricular chamber. The procedure is based on the premise that the beneficial effects of Left Ventricular Reconstruction (LVR) via radius and volume reduction, can be realized by excluding a portion of the scarred left ventricle wall circumference. The procedure is similar to a Dor procedure except that it utilizes a series of anchors in place of the Fontan stitch and patch to exclude infarcted tissue and reduce the size of the left ventricle chamber and the scarred left ventricle wall. Because the ventricle is not resected, it is possible to do the procedure without a cardiopulmonary bypass pump. The validity of this concept has been documented. Geometric confirmation was initially accomplished in a bench model, where radius was decreased by 24% and volume was diminished by 35% after exclusion of an antero-septal wall segment in dilated, explanted porcine hearts. When using the PliCath System in accomplishing LV reconfiguration, the fundamental technical maneuver is placement of a hollow needle through a predetermined site in the anterior wall scar, across the LV chamber, and through a predetermined site in the scarred interventricular septum. Once achieved, a flexible guidewire is advanced through the needle and into the free right ventricular (RV) chamber. Once the wire is completely through the septum, a dilator enables passage of a 14Fr Introducer to traverse the needle route, allowing introduction of an internal, elongated anchor which can be oriented into appropriate alignment and matched with an external anchor of identical length and alignment. The anchors, which are placed in the RV and on the epicardium as a result of the original needle passage, can be brought toward each other until contact between the two walls is established and they are apposed along their lengths. The action is repeated (i.e., repeated needle sticks and anchor placement), along the long axis of the LV until a linear portion of antero-lateral wall is in contact with a corresponding portion of the septum, excluding the entire intervening wall segment from the circumference of the chamber. The device is designed to allow removal at any stage of deployment prior to removal of the "Leash" attached to the hinged, internal anchor. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01568138
Study type Interventional
Source BioVentrix
Contact
Status Completed
Phase N/A
Start date August 2010
Completion date August 2015

See also
  Status Clinical Trial Phase
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy