The C-Pulse Study is evaluating the safety and performance of a new product for the treatment of heart failure. The product is designed to help reduce the symptoms of heart failure and help patients function better with daily activities. The study evaluates multiple measures of heart function and whether the patient's quality of life has been improved since the device implant. The patient will have several visits after the device implant to assess how well they are doing and to monitor any safety concerns.


Clinical Trial Description

Sunshine Heart Inc. is sponsoring a prospective trial to assess the safety and provide indications for performance of the Sunshine Heart C-PulseTM System ("C-Pulse™"). The current need is for a counterpulsation device or method that is effective enough to make its application appealing as a long-term implant to a large number of patients and physicians. It must be simple and safe, with a straight-forward implant procedure, and with long-term measurable patient benefits. Further, it would be advantageous for the counterpulsation device to be smaller, easier to insert, ambulatory, disconnectable, and not in the bloodstream. Such a device may be more readily adopted by a wider group of cardiologists and surgeons, and be suitable for a wider group of people in NYHA Class III or IV heart failure. It is important to point out that a counterpulsation device is aimed to augment native heart function and is fundamentally different from total artificial hearts, left ventricular assist devices and heart transplants which are meant to be a total replacement or an alternative to the native heart. Thus, the counterpulsation device is considered non-obligatory and not life-supporting. Sunshine Heart, Inc has proposed C-Pulse™, a novel ambulatory, non-obligatory, non-blood contacting extra-ascending aortic counterpulsation system. The C-Pulse™ System is designed to be implanted without the need for cardiopulmonary bypass or extensive dissection, to be able to be activated immediately, to augment heart function in a safe manner and to provide sustained relief from heart failure symptoms. It can be turned off safely, and similarly, in failure modes, is considered to have an associated low risk of death or disability, other than the recurrence of heart failure symptoms. C-Pulse™ is not an alternative to the heart, it is an augmentation device, and it does not preclude the use of therapies that provide full circulatory support such as heart transplantation or LVADs. The C-Pulse™ System consists of a counterpulsation Cuff secured around the outside of the ascending aorta, the main blood vessel out of the heart. The Cuff and a heart signal sensing wire are attached to an external driver. The external Driver inflates and deflates the Cuff in sequence with the ECG signal to assist heart function and improve the pumping capacity of the heart. The Cuff deflects the aorta in a "thumb-printing" manner which has been optimized to minimize aortic wall strain and maximize blood volume displacement per beat. The C-Pulse™ System is non-blood contacting, simple to insert, and can be turned on and off as required; all natural blood pathways are maintained - there is no exposure of foreign material to the bloodstream. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01176370
Study type Interventional
Source Nuwellis, Inc.
Contact
Status Terminated
Phase N/A
Start date June 21, 2010
Completion date April 30, 2015

See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy