Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT04617912
Other study ID # 843546
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date November 12, 2020
Est. completion date November 1, 2026

Study information

Verified date April 2024
Source University of Pennsylvania
Contact Erin K Schubert
Phone 215-573-6569
Email erinschu@pennmedicine.upenn.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Positron Emission Tomography (PET) is a procedure that uses a special type of machine to take pictures of the inside of the body after a radioactive drug is administered. The radioactive drug that is used for this study may be an FDA approved imaging drug or may be used as an investigational imaging drug as part of another study for which participants are taking part. PET using various radiotracers is useful for the diagnosis of various diseases, including cancer, brain diseases, infection, and heart or lung disease. The purpose of this study is to test a research PET machine called the PennPET Explorer long-axial field-of-view scanner. This research PET machine can image a larger section of the body than the current clinical PET scanners, allowing most of the body to be imaged at one time. This scanner is still an investigational device and is being tested in this study to collect more information about how best to use this type of whole body scanner.


Description:

The PennPET Explorer is a multiring system with a long AFOV that is scalable and comprised of multiple 22.9 cm long ring segments, each with 18 detector modules based on a commercial digital silicon photomultiplier. Initial testing data on a prototype 3-ring-segment instrument with an active 64-cm AFOV has been collected and published by Karp et al., and Pantel et al., [Karp 2020, Pantel 2020], validating the system design and demonstrating its initial performance. In the last two decades, commercial PET scanner performance has improved dramatically with CT-based attenuation correction 1, the use of lutetium oxyorthosilicate or lutetium-yttrium oxyorthosilicate scintillators, time-of-flight reconstruction 2-5, and, most recently, silicon photomultiplier (SiPM)-based time-of-flight detectors 2,6. However, the AFOV has not grown; it remains 16-26 cm for the newest commercial SiPM-based scanners 7,8. This choice is due mainly to scintillator and SiPM photosensor costs and the prevalence of clinical 18F-FDG scanning focused on measuring lesion SUV when the uptake is assumed to be at steady state, typically at 60 min after injection. The newest commercial instruments perform an 18F-FDG whole-body survey (skull-base to mid-thigh) with excellent diagnostic quality in 10-20 min using bed translation. The motivation for a LAFOV PET system is to use its high sensitivity to enhance clinical performance and to enable research applications. Clinically, a LAFOV system could enable faster imaging, imaging with lower injected activities, or a combination of the two. Research applications include delayed imaging, improving quantification for kinetic modeling, and applications requiring simultaneous measurement of multiple organ systems 9,10. It is unknown whether such a system would primarily be used for clinical or research applications. The investigators developed the PennPET Explorer whole-body imager to support both applications. Performance measurements were taken on the prototype 3-ring-segment system to optimize the hardware and software acquisition and reconstruction, as well as to demonstrate the capabilities of the PennPET Explorer. The investigators are operating with a total of 6 ring-segments which will give an active 140 cm AFOV. This will allow whole-body imaging in one bed position for most adults. In the evaluation of a new instrument, human studies are essential to establish the real-world performance beyond phantom studies, as well as to test and optimize data acquisition and reconstruction. To date 11 human studies have been imaged on the prototype scanner under IRB 809476. This instrument was determined by the FDA to meet the definition of a nonsignificant risk (NSR) device and is therefore subject only to abbreviated IDE requirements. Once the additional ring-segments have been added to the instrument, the investigators plan to continue testing this scanner in human subjects under this ongoing open-ended protocol. The investigators will continue to work towards optimizing performance and data acquisition until such time as this device receives full FDA 510(k) approval. This protocol is designed to test the PennPET Explorer instrument with its final AFOV of 140 cm. PET imaging involves the administration of a radioactive imaging drug that emits positrons which are detected by the scanner and used to form the images. For the purposes of this protocol, the administered radioactive imaging drug (tracer) will vary; it may be an FDA-approved radiotracer or an experimental radiotracer that is used under an IND. If the radiotracer used is under an IND, then the administration of the radiotracer will be done under the purview of a separate protocol for which the subject has been separately consented. This protocol and the corresponding ICF involves consent only for being scanned on the investigational scanner and does not pertain to the administration of an investigational radiopharmaceutical.


Recruitment information / eligibility

Status Recruiting
Enrollment 99
Est. completion date November 1, 2026
Est. primary completion date November 1, 2026
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Adult participants, at least 18 years of age - Participants or study partner must be informed of the investigational nature of this study and provide written informed consent in accordance with institutional and federal guidelines prior to study-specific procedures. Subjects who are unable to provide consent must have a legally authorized representative or designated "study partner" who can provide consent on their behalf. Exclusion Criteria: - Inability to tolerate imaging procedure in the opinion of an investigator. - Serious or unstable medical or psychological conditions or lack of mobility that, in the opinion of the investigator would compromise the subject's safety or successful participation in the study

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Long AFOV PennPET Explorer
A long-axial field-of-view (LAFOV) time-of-flight PET scanner, developed at the University of Pennsylvania, being tested for real-world applications.

Locations

Country Name City State
United States University of Pennsylvania Philadelphia Pennsylvania

Sponsors (1)

Lead Sponsor Collaborator
University of Pennsylvania

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Image Performance of the LAFOV PennPET Explorer Noise behavior, structural detail and local contrast will be combined to report overall image quality using a numerical scale (1 = poor image quality, 5 = superior image quality). Through study completion, an average of 1 year.
See also
  Status Clinical Trial Phase
Recruiting NCT06052553 - A Study of TopSpin360 Training Device N/A
Completed NCT05511077 - Biomarkers of Oat Product Intake: The BiOAT Marker Study N/A
Recruiting NCT04632485 - Early Detection of Vascular Dysfunction Using Biomarkers From Lagrangian Carotid Strain Imaging
Completed NCT05931237 - Cranberry Flavan-3-ols Consumption and Gut Microbiota in Healthy Adults N/A
Completed NCT04527718 - Study of the Safety, Tolerability and Pharmacokinetics of 611 in Adult Healthy Volunteers Phase 1
Terminated NCT04556032 - Effects of Ergothioneine on Cognition, Mood, and Sleep in Healthy Adult Men and Women N/A
Completed NCT04065295 - A Study to Test How Well Healthy Men Tolerate Different Doses of BI 1356225 Phase 1
Completed NCT04107441 - AX-8 Drug Safety, Tolerability and Plasma Levels in Healthy Subjects Phase 1
Completed NCT04998695 - Health Effects of Consuming Olive Pomace Oil N/A
Completed NCT01442831 - Evaluate the Absorption, Metabolism, And Excretion Of Orally Administered [14C] TR 701 In Healthy Adult Male Subjects Phase 1
Terminated NCT05934942 - A Study in Healthy Women to Test Whether BI 1358894 Influences the Amount of a Contraceptive in the Blood Phase 1
Recruiting NCT05525845 - Studying the Hedonic and Homeostatic Regulation of Food Intake Using Functional MRI N/A
Completed NCT05515328 - A Study in Healthy Men to Test How BI 685509 is Processed in the Body Phase 1
Completed NCT05030857 - Drug-drug Interaction and Food-effect Study With GLPG4716 and Midazolam in Healthy Subjects Phase 1
Completed NCT04967157 - Cognitive Effects of Citicoline on Attention in Healthy Men and Women N/A
Recruiting NCT04494269 - A Study to Evaluate Pharmacokinetics and Safety of Tegoprazan in Subjects With Hepatic Impairment and Healthy Controls Phase 1
Recruiting NCT04714294 - Evaluate the Safety, Tolerability and Pharmacokinetics Characteristics of HPP737 in Healthy Volunteers Phase 1
Completed NCT04539756 - Writing Activities and Emotions N/A
Recruiting NCT04098510 - Concentration of MitoQ in Human Skeletal Muscle N/A
Completed NCT03308110 - Bioavailability and Food Effect Study of Two Formulations of PF-06650833 Phase 1