Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04310982
Other study ID # Gazi U
Secondary ID
Status Completed
Phase
First received
Last updated
Start date June 3, 2019
Est. completion date February 15, 2020

Study information

Verified date March 2020
Source Gazi University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

Gait analysis is an effective tool used for a variety of purposes, including assessing neurological diseases, risk of falling, orthopedic disability and progress during rehabilitation.The analysis of gait and jump performance must be applicable in a clinical setting. Thus; it needs to be easy to apply in a variety of life situations.The measurements should be reproducible, stable, accurate, capable of distinguishing between normal and abnormal conditions, and cost-effective. Jump measures can predict injury risks, serve as talent identification, and replicate explosive competitive activities of athletes. Furthermore, the performance in vertical jumping can be associated with neuromuscular fatigue.The purpose of this study was to confirm the test-retest reliability of the G-walk wearable sensor system for gait and jump parameters in healthy adults.


Description:

The G-Walk determines spatiotemporal parameters as well as pelvic rotations during gait and allows objective and precise analysis of movements with its wearable inertial sensor. It also enables 3D kinematic analysis of the pelvis, providing a functional analysis of disorders in gait caused by neuromuscular diseases The device is placed on an elastic belt and worn on the waist of the person being evaluated, with the center of the device at the fifth lumbar vertebrae. To ensure correct placement of the device, the L4-L5 intervertebral space was palpated via the posterior superior iliac spines.

After the accelerometer was placed, the participants were asked to walk calmly at normal speed, on a 10 m track, and to return to the starting position.

The values and gait characteristics of acceleration in the anteroposterior and mediolateral axes were transferred to the computer software program.

The tilt of the pelvis in the sagittal plane in the flexion-extension direction, the oblique displacement in the coronal plane, the angles of the rotation of movement in the transverse plane and the symmetry values of the right and left sides are obtained. While the symmetry index ranges from 0 to 100, a value closer to 100 indicates that the gait is more symmetrical Following gait assessment, Countermovement jump, static squat jump and Countermovement jump with arms thrust was measured using the device.


Recruitment information / eligibility

Status Completed
Enrollment 49
Est. completion date February 15, 2020
Est. primary completion date October 30, 2019
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 35 Years
Eligibility Inclusion Criteria:

- Accepting to participate in the study,

- Healthy adults,

- Being 18-35 years old,

Exclusion Criteria:

- having any musculoskeletal, neurological or other pathology potentially affecting their gait and jump performance,

- Refusing to participate in the study,

- Having limited cooperation which prevents participation in the study,

Study Design


Related Conditions & MeSH terms


Intervention

Device:
The G-Walk sensor system (G-Walk)
The G-Walk is a wireless sensor device which is placed on an elastic belt and worn on the waist of the person being evaluated. The device is placed with the center of the device at the fifth lumbar vertebrae and the patient is completely free to walk, run and jump wearing this device. The gait and jump performance of the participants was assessed with the participants wearing this device two times to investigate the test-retest reliability. The second being 7 days after the first.

Locations

Country Name City State
Turkey Gazi University Ankara

Sponsors (1)

Lead Sponsor Collaborator
Gazi University

Country where clinical trial is conducted

Turkey, 

Outcome

Type Measure Description Time frame Safety issue
Primary Gait Analysis Gait parameters will be assessed via the G-Walk on two separate occasions. The G-Walk is a device that is worn on the waist via an elastic belt. The G-Walk is built with a triaxial accelerometer 16 bit/axes with multiple sensitivity, a triaxial magnetometer 13 bit and a triaxial gyroscope 16 bit/axes with multiple sensitivity. This hardware is capable of acquiring and transmitting data to a computer through a Bluetooth connection and at the end of each analysis an automatic report containing the gait assessment results is ready to be analyzed.
Gait symmetry values of the right and left sides are obtained within this report. While the symmetry index ranges from 0 to 100, a value closer to 100 indicates that the gait is more symmetrical.
Reliability of the G-Walk in 7 days
Primary Jump performance The jump tests protocols included; counter movement jump , squat jump and counter movement jump with arms thrust. At the end of the jump tests, all kinematic parameters concerning the evaluated jump were provided by the software. T Each participant performed a session of three trials for each of the assessed jumps. The jump with the maximum height was accepted for analysis. Reliability of the G-Walk in 7 days
Secondary Jump height The jump tests protocols included; counter movement jump , squat jump and counter movement jump with arms thrust. At the end of the jump tests, the height of the jump was given in centimeters by the software. Reliability of the G-Walk in 7 days
Secondary Peak speed The jump tests protocols included; counter movement jump , squat jump and counter movement jump with arms thrust. At the end of the jump tests, the peak speed of the jump was given in meters/second by the software. Reliability of the G-Walk in 7 days
Secondary Maximum concentric power The jump tests protocols included; counter movement jump , squat jump and counter movement jump with arms thrust. At the end of the jump tests, the maximum concentric power of the jump was given in Newtons by the software. Reliability of the G-Walk in 7 days
See also
  Status Clinical Trial Phase
Recruiting NCT06052553 - A Study of TopSpin360 Training Device N/A
Completed NCT05511077 - Biomarkers of Oat Product Intake: The BiOAT Marker Study N/A
Recruiting NCT04632485 - Early Detection of Vascular Dysfunction Using Biomarkers From Lagrangian Carotid Strain Imaging
Completed NCT05931237 - Cranberry Flavan-3-ols Consumption and Gut Microbiota in Healthy Adults N/A
Terminated NCT04556032 - Effects of Ergothioneine on Cognition, Mood, and Sleep in Healthy Adult Men and Women N/A
Completed NCT04527718 - Study of the Safety, Tolerability and Pharmacokinetics of 611 in Adult Healthy Volunteers Phase 1
Completed NCT04065295 - A Study to Test How Well Healthy Men Tolerate Different Doses of BI 1356225 Phase 1
Completed NCT04998695 - Health Effects of Consuming Olive Pomace Oil N/A
Completed NCT04107441 - AX-8 Drug Safety, Tolerability and Plasma Levels in Healthy Subjects Phase 1
Completed NCT01442831 - Evaluate the Absorption, Metabolism, And Excretion Of Orally Administered [14C] TR 701 In Healthy Adult Male Subjects Phase 1
Terminated NCT05934942 - A Study in Healthy Women to Test Whether BI 1358894 Influences the Amount of a Contraceptive in the Blood Phase 1
Recruiting NCT05525845 - Studying the Hedonic and Homeostatic Regulation of Food Intake Using Functional MRI N/A
Completed NCT05515328 - A Study in Healthy Men to Test How BI 685509 is Processed in the Body Phase 1
Completed NCT05030857 - Drug-drug Interaction and Food-effect Study With GLPG4716 and Midazolam in Healthy Subjects Phase 1
Completed NCT04967157 - Cognitive Effects of Citicoline on Attention in Healthy Men and Women N/A
Recruiting NCT04714294 - Evaluate the Safety, Tolerability and Pharmacokinetics Characteristics of HPP737 in Healthy Volunteers Phase 1
Recruiting NCT04494269 - A Study to Evaluate Pharmacokinetics and Safety of Tegoprazan in Subjects With Hepatic Impairment and Healthy Controls Phase 1
Completed NCT04539756 - Writing Activities and Emotions N/A
Recruiting NCT04098510 - Concentration of MitoQ in Human Skeletal Muscle N/A
Completed NCT03308110 - Bioavailability and Food Effect Study of Two Formulations of PF-06650833 Phase 1