View clinical trials related to Healthcare Associated Infection.
Filter by:The goal of this clinical trial is to evaluate the potential effects of photobiomodulation when used with topical disinfectants in the anterior nares of healthy adults. Over a three week period, participants will have their anterior nares swabbed with methylene blue, chlorhexidine gluconate, or a combination of the two followed by 4 minutes of non-thermal red light treatment. The fourth week of consist of only red light treatment. Culture samples of the subjects nasal microbiome will be taken prior to treatment, immediately after treatment, 4-, 8-, 24-, and 48 hours after treatment.
CUPRIC is an investigator initiated and conducted, prospective, quasi-experimental study to determine whether the combined use of copper-alloyed objects plus copper-enriched textiles reduce the burden of MDRO colonization and HAIs incidence in the critically ill population.
Ventilation with fresh outdoor air has recently gained considerable attention as a means to reduce the potential risk of indoor aerosol transmission of respiratory pathogens such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus causing coronavirus disease 2019 (COVID-19). Commercial carbon dioxide (CO2) monitors are increasingly used in schools, long-term care facilities, offices and public buildings to monitor indoor ventilation. However, no formal evidence is available to support the effectiveness of feedback from CO2 monitoring devices. Moreover, modern hospitals have superior indoor air quality control systems. The aim of this prospective pilot randomized controlled trial (RCT) is to evaluate whether CO2 monitoring devices would be useful as a means to further maintain lower indoor CO2 concentrations in hospitals.
Venous congestion in transplanted or re-implanted tissues remains a common and chal-lenging complication in plastic and reconstructive surgery. Local application of medicinal leeches is effective to reduce postoperative venous congestion of the flap and to restore normal blood flow. However, leech therapy is associated with a number of risks, including infections. Indeed, leeches maintain a symbiotic relationship with Aeromonas species in order to digest blood in their gut. Aeromonas spp. infections can occur 1 to 30 days post-application of leeches and are associated with a dramatic decrease in flap salvage rates (88 to 30%). For these reasons, prophylactic antibiotics and, external decontamination are widely recommended throughout the course of leech therapy. The aim of this study is to investigate the prevalence of side effects (anemia and infection) from patients treated with leeches in French Hospital.
The purpose of this study is to determine if use of the video camera surveillance system for HH observation and performance feedback about HH compliance rates can improve the HH compliance of HCWs and reduce healthcare-associated infections in the NICU.
Annually, more than 250,000 patients in the U.S. with end-stage heart failure stand to benefit from ventricular assist device (VAD) therapy. 60% of patients develop a healthcare-associated infection (HAI) within 90-days of implantation. The investigators long term goal is to develop and subsequently promote wide-scale adoption of evidence-based HAI prevention practices following durable VAD implantation. This will be done by addressing the following aims: Aim 1. Identify determinants of center-level variability in HAI rates. Aim 2. Develop a comprehensive understanding of barriers and facilitators for achieving low center HAI rates. Aim 3. Develop, iteratively enhance, and disseminate a best practices toolkit for preventing HAIs that accommodates various center contexts. The investigators will use a focused survey of U.S. VAD centers to identify determinants of center variation in 90-day HAI rates: - Process Factors (e.g., intranasal mupirocin), - Provider Factors (e.g., surgeon technique), - Device Factors (e.g., centrifugal vs. axial), - Center Factors (e.g., provider communication). Understanding the barriers and facilitators within individual centers for maximizing adoption of prevention measures would serve as the foundation for targeted improvement strategies. Without this knowledge, evidence-based, action-oriented recommendations will have limited local adoption and ultimately effectiveness in preventing HAIs after VAD implantation.
The objective is to conduct a prospective, sham controlled, double-blinded, interventional crossover trial to compare standard terminal cleaning plus PX-UV (intervention) with standard terminal cleaning plus sham PX-UV (control) with crossover at 12 months, following a 6-month washout period. Outcome measures include the rates of HAIs, as well as the recurrence of genetically identical clinical strains of HAIs among patients on study units. The study will be conducted in 2 hospitals covering 16 total hospital units at Detroit Medical Center. Our central hypothesis is that the addition of PX-UV to standard terminal cleaning will be associated with a significant reduction in the rate of HAIs, as well as a reduction in the recovery of genetically identical strains of MDROs. The impact of PX-UV disinfection on rates of HAIs on study units will be determined by comparing rates of HAIs on a) study units where PX-UV is added to standard terminal cleaning practices to b) units where a sham UV disinfection system is added to standard terminal cleaning; and by comparing rates of HAIs on the same medical ward during each of two 12-month phases of a crossover study (one phase when a PX-UV device is added and one when a sham device is added to standard terminal cleaning). The long-term goal of this project is to establish the efficacy of terminal cleaning plus PX-UV in reducing rates of HAIs due to the following multi-drug resistant organisms (MDROs): C. difficile, vancomycin-resistant enterococci (VRE), Klebsiella pneumoniae and Escherichia coli producing extended-spectrum beta-lactamases (ESBLs), methicillin-resistant Staphylococcus aureus (MRSA) and Acinetobacter baumannii. At the conclusion of the proposed project, novel data will be generated from this rigorously controlled study regarding the effectiveness of PX-UV in reducing HAIs in a representative, real-world healthcare setting.
This research will test a new ultra-rapid technology (called ID/AST Accelerate system) that uses a digital microscope to identify bacteria based on their growth patterns. This method does not have to wait for bacteria to grow in a lab. The new method can identify the type of bacteria within 2 hours of receiving a specimen. The new method also shows the effect of selected antibiotics on the bacteria including multidrug resistant bacteria so that doctors know within 6 hours from specimen collection which antibiotic kills the bacteria. To check the accuracy, speed and impact of the new method on antibiotic prescribing, investigators are proposing a study with two parts; The first part will test the accuracy and speed of the results obtained by the new method. The second part will test if having the results from the new method early would change the antibiotics prescribed to a patient in a simulation experiment. An independent infectious disease physician will be shown the results from the new method and asked if the results were accurate, would it change the antibiotic treatment for the patient.
This study examines the impact of UV-C light disinfection as an adjunct to routine daily and discharge patient room cleaning on patient infection and colonization with hospital associated bacteria. Patient rooms are counted as enrolled since consent was waived and the number of participants is unknown. Total of 83 rooms.
Military service members and the U.S. veteran population face a growing and serious health threat: widespread antibiotic resistance resulting from resistant bacteria and a dwindling pipe-line of sufficiently potent antibiotics. Infections with antibiotic resistant bacteria are increasing significantly. They cause major complications and mortality, and drive up healthcare costs. Powerful but non-targeted antibiotics, while in widespread use, can actually pressure bacteria to develop resistance.