Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to compare the quantity of fat that is released into the venous system (blood) by reaming the femoral canal during intramedullary nailing of the femur using two different reaming systems.


Clinical Trial Description

Twenty patients who meet criteria for inclusion in this study will be assigned to one of two groups by means of a computer-generated random number. Group A will consist of 10 patients who undergo reaming with the Synthes reamer-irrigator-aspirator (RIA). Group B will consist of 10 patients who undergo conventional reaming with the Zimmer Sentinel reamer.

The patient will be transported to the operating room and will undergo general anesthesia. After correct positioning of the patient on the radiolucent table, baseline data will be collected. This data will consist of a transesophageal echocardiogram (TEE) and arterial blood gas.

A standard lateral approach to the proximal femur will be utilized. The starting point will be identified using a guide pin and fluoroscopy using standard technique. Though the resident may perform the approach, the attending surgeon will perform the case from the opening of the canal with a drill through the completion of reaming. A TEE will be recorded from the time the initial reamer engages the cortex until it is removed from the bone. A guide wire will be passed across the fracture site and its position confirmed by fluoroscopic imaging. The femoral canal will be reamed using either a conventional reaming technique or the RIA device.

For conventional reaming, successive reamers will be used beginning with an 8mm end-cutting reamer and increasing by 1.0 mm increments until cortical "chatter" is detected, then reaming will proceed at 0.5 mm increments for two passes. This is the standard practice using current technology. A Synthes titanium nail of the appropriate length which is 1.0 - 1.5mm less than the last reaming will be chosen for implantation. TEE will be monitored during the pass of the first reamer and the last.

For reaming with the RIA, a reamer-irrigator-aspirator of the appropriate size based on pre-operative evaluation of the femoral canal size will be used to perform a single pass down the femoral canal. A Synthes titanium femoral nail of the appropriate length will be selected for implantation. TEE will be recorded during the reaming. An arterial blood gas will be sent after positioning of the patient, when the guide wire is passed down the femoral canal and after the proximal locking screws are placed.

Proximal and distal locking screws will be placed in standard fashion. Wound closure and post-operative care will be according to standard protocols.

The TEE will be evaluated in a blinded manner by two anesthesiology attendings certified to use and evaluate the TEE. A grading system of 1 through 5 will be used, with 1 representing little to no fat emboli and 5 representative of a large number of fat emboli. This data will be forwarded to the principal investigator and used to fill the appropriate data sheet.

Outpatient follow-up will be performed in the usual manner, with sutures/staples being removed at approximately 2 weeks, and radiographs being obtained at 6 and 12 weeks as the attending physician deems clinically necessary. Follow-up for both limbs of the study will be the same as patients not in the study who undergo femoral nailing. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00594438
Study type Interventional
Source University of Alabama at Birmingham
Contact
Status Completed
Phase N/A
Start date January 2007
Completion date December 2007

See also
  Status Clinical Trial Phase
Completed NCT03231787 - Clinical Trial in Antiaggregated Patients With Proximal Femur Fracture Evaluating a Strategy to Shorten Time Until Surgery N/A
Completed NCT00888160 - Timing of Orthopaedic Surgery in the Multiply-injured Patient: Development of a Protocol for Early Appropriate Care
Completed NCT05613257 - Distal Targeter vs Free-hand N/A
Withdrawn NCT00240396 - Bimodal Analgesia as Form of Pain Control Post Long Bone Fracture N/A
Recruiting NCT01969279 - Radiographic Influences of Bisphosphonate Treatment on Femur N/A
Terminated NCT03160508 - Trochanter Fixation Nail Advanced (TFNA) Weight Bearing
Completed NCT04127045 - ProspEctive Cohort Study on Multidisciplinary Approach to Femur FRactures' manAgement in Over 65 Population
Recruiting NCT03868280 - The FLiP Study, a Pilot Cluster Randomized Trial N/A
Completed NCT00725894 - Pediatric Locking Nail for the Treatment of Femoral Fractures in Children N/A
Recruiting NCT04657510 - Femoral frACturEs and COVID-19.
Completed NCT05225753 - Post-operative Anemia in Lateral Fractures of the Femur.
Active, not recruiting NCT03775408 - FAST: Clinical Feasibility
Completed NCT02793947 - Efficacy of Peri-Incisional Multimodal Drug Injection Following Operative Management of Femur Fractures Phase 4
Completed NCT00916136 - Skeletal Versus Cutaneous Traction For Treatment of Femur Fractures N/A
Completed NCT06430944 - Comparative Study Between Single and Double Limb Hip Spica Cast in Fracture Femur in Young Children N/A
Completed NCT05183308 - Combined Drug Therapy in Lateral Fragility Fractures of the Femur
Not yet recruiting NCT00616044 - Continuous Spinal Anesthesia Versus Combined Spinal Epidural Block N/A
Terminated NCT01484405 - Anterolateral Versus Posterior Approach for Total Hip Arthroplasty After Displaced Femoral Neck Fracture N/A
Completed NCT00943332 - Pediatric Femur Research Project
Not yet recruiting NCT00686023 - Comparing Surgical Techniques for CRIF of Pertrochanteric Fractures N/A