View clinical trials related to Embolism.
Filter by:The STRATIFY II trial investigates the efficacy of three different approaches to reducing thrombus burdon in patients with acute intermediate high-risk pulmonary embolism: percutaneous embolectomy (the Flow Triever® system, INARI medical), USAT (EKOS® system, Boston Scientific with low dose alteplase) and heparin with the option to perform full-dose thrombolysis. As a co-primary secondary end point the trial assess the incremental efficacy of the embolectomy vs the catheter based low dose thrombolysis approach. Thus the two main hypothesis being tested are: 1. Thrombus burden reduction after 48-96 h is increased with a catheter based (embolectomy or USAT) compared to the a heparin with optional high dose thrombolysis approach (1st co-primary outcome) 2. Thrombus burden reduction after 48-96 h is increased with percutaneous embolectomy compared to USAT with low-dose alteplase (2nd co-primary outcome)
This study is a quality improvement project to evaluate health care management of pulmonary embolism (PE) patients. The researchers are testing an intervention to determine if it prevents unnecessary hospital admissions.
Background Blood transfusions in pregnancy are usually urgent, unpredictable, and occur in otherwise healthy women. There is evidence of increasing rates of maternal red blood cell (RBC) transfusion around childbirth both in Europe and in US. Indeed, they are recorded in approximately 0.4-1.6% of all deliveries. Although obstetric patients use a small proportion of the blood supply overall (3-4%), however over the last years there has been a significant increase (about 30%) in the use of blood and blood products throughout pregnancy. Most available data relate to the peri-partum period, defined as those occurring from 48 hours before delivery onwards. Anemia in pregnancy is associated with increased maternal mortality and fetal intrauterine growth restriction (IUGR). The risk of these adverse effects is proportional to the severity of anemia; for instance, preterm birth and low birth weight rates are particularly high among women with a hemoglobin below 7 g/dL. The presence of anemia in at-term pregnant women is a rather frequent and unrecognized risk factor for peri-partum hemorrhage (PPH) transfusion. In a retrospective investigation, we have calculated that almost 20% of at-term pregnant women show iron deficiency anemia. It has been suggested that reduction of RBC transfusion in the context of PPH may decrease maternal mortality and, at the same time, reduce costs. Patient's Blood Management (PBM) is a well-known strategy based on 1) identification of anemia; 2) reduction of blood loss and 3) reduction of RBC transfusion. In several medical specialties, recommendations based on available evidence highlighted the concept that a restrictive RBC administration is safe and efficacious. Despite the fact that the WHO has recommended PBM early 2010, the majority of hospitals are in need of guidelines to apply PBM in daily practice. Rationale Anemia is a frequent and often unrecognized hallmark of at-term pregnancies. Systematic collection of data on transfusion practice during pregnancy and post-partum period are scarce. The application of PBM in obstetrics is expected to improve pregnancy outcome and optimize resources. Objectives Objectives of the present study are 1. To estimate: frequency of anemia in pregnancy and feto-maternal complications, distribution of haemorrhage aetiologies and transfusion indications. 2. To evaluate associations of these outcomes with gestational age, and transfusion dose.
The study aim is to determine whether electrical impedance tomography (EIT) is equivalent in the detection of pulmomary emboli compared to Computed Tomographic Angiography (CTA). EIT is a non-invasive, non-ionizing functional imaging technique that can be performed at bedside. Electrical impedance tomography data will be collected on individuals undergoing a CTA scan of the chest at Medical Center of the Rockies (MCR). The primary outcome measure is to assess whether assessment by CTA corresponds with EIT in detection of pulmonary emboli. The study will include up to 63 participants. EIT data will be collected for up to 20 minutes during tidal breathing and for approximately five to ten seconds during breath-holding.
This multi-center retrospective study collected clinical, laboratory, and CT pulmonary angiography parameters with acute pulmonary embolism patients from admission to predict adverse outcomes within 30 days after admission into hospital.
The objective of the study is to evaluate the safety and efficacy of the Adient absorbable filter for the prevention of pulmonary embolism (PE: blood clot in the lungs). PE claims the lives of over 100,000 Americans each year, more than breast cancer, traffic fatalities and HIV combined. Pharmaceutical anticoagulation (blood thinners) that reduce blood clot formation represent the standard of care for treating patients at risk for PE. However, for people who are temporarily unable to use anticoagulants, such as those who have suffered major trauma or those who are scheduled for surgical procedures, inferior vena cava (IVC) filters are used to help protect against PE. These blood filters prevent large blood clots that originate in the deep veins of the legs (deep vein thrombosis (DVT)) from reaching your lungs causing a potentially life-threatening PE. Conventional metal IVC filters have been proven effective at reducing the incidence of PE, however, most require retrieval. If not retrieved within a timely manner (months), they can perforate the IVC, impale nearby organs with their barbed struts, and cause blood clots. In contrast, the Adient absorbable filter traps blood clots similar to conventional metal IVC filters, but following the 8 week protection period, the filter itself breaks down into carbon dioxide and water. Hence no filter retrieval is required and complications are less likely due to the shortened indwell time. Once blood clots are trapped in the absorbable filter, the body's thrombolytic enzymes dissolve the clots within weeks while the filter itself resorbs in 6 to 8 months. The absorbable filter is braided from absorbable suture that has been proven safe over 4 decades. The question being addressed with the randomized controlled trial portion is whether the placement of the absorbable filter in addition to current best practice PE prevention (sequential compression machines, compression stockings, and anticoagulants when indicated) significantly reduces the incidence of clinically significant PE in high risk subjects. The absorbable filter will be indicated for the temporary prevention of PE in patients with transient high risk for venous thromboembolism (DVT and/or PE) with or without venous thromboembolic disease and as an enhancement to pharmaceutical anticoagulation and mechanical prophylaxis.
This retrospective cohort study aims to characterise outcomes for patients treated on an intensive care unit (ICU) with COVID-19 in England and Wales, one year after discharge from hospital. Outcomes will be compared with patients admitted as an emergency to an ICU for other conditions. The study will use existing national audit data linked to routine healthcare datasets.
Chest computed tomography of patients having coronavirus disease (COVID-19) will be analyzed with regards to vascular abnormalities (pulmonary embolism and vascular thickening), and their association with lung inflammation. The prevalence, severity, distribution, and prognostic value of chest CT findings will be assessed. Patients with vascular abnormalities will be compared to patients without, which is supposed to provide insights into the prognostic role of such abnormalities, and the potential impact on treatment strategy.
In patients with symptoms of Venous Thromboembolism (VTE) (mainly deep vein thrombosis (DVT) or pulmonary embolism (PE)), the study will evaluate the agreement between the D-Dimer measurements from the LumiraDx POC D-Dimer assay and a reference method, as an aid in diagnosis, assessment and exclusion of DVT and PE.
The primary purpose of this study is to determine the optimal duration of anticoagulation therapy (6 months versus 18 months) with direct oral anticoagulant (DOAC) for cancer-associated low-risk pulmonary embolism patients. The major secondary purpose of this study is to investigate whether home treatment of cancer-associated low-risk pulmonary embolism patients with rivaroxaban is feasible, effective, and safe through an observational management study.