Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT05023798
Other study ID # 04-001
Secondary ID
Status Not yet recruiting
Phase
First received
Last updated
Start date September 15, 2021
Est. completion date August 30, 2022

Study information

Verified date August 2021
Source Afon Technology
Contact Steve Luzio
Phone +44 (0)1792 295078
Email S.Luzio@swansea.ac.uk
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

1. Diabetes mellitus is a chronic disease currently affecting more than 425 million people, of which one-third are people older than 65 years. In the UK, the number of people currently diagnosed with diabetes surpassed 3.8 million in 2019, with someone being diagnosed with the illness every two minutes (Diabetes.org figures). The prototype device being tested is a non-invasive blood glucose measurement system worn on the wrist. This would help people with diabetes manage their condition better and help prevent complications. 2. The main objectives of the research are: 1. To determine how accurate and effective the Afon prototype non-invasive blood glucose measurement system is, as compared to a gold standard invasive method. 2. To chart the Afon device's predicted blood glucose levels over time. 3. The study will be done with 30-50 patients. Eligible patients will have been diagnosed with diabetes (type 1 or 2) at least one year prior, be between 18 and 80 years old, and with a BMI between 18-35 kg/m2. For details of the full list of inclusion and exclusion criteria, see accompanying documentation. 4. The trial will be conducted at the Joint Clinical Research Facility (JCRF), Institute of Life Science 2, Swansea University, SA2 8PP. 5. Participants will attend the site for a total of 5 visits, one for screening, and four study visits, no more than 7 days apart. The study will run for one year.


Description:

Diabetes is a chronic disease currently affecting more than 425 million people worldwide. In the UK, the number of people currently diagnosed with diabetes surpassed 3.8 million in 2019, with someone being diagnosed with the illness every two minutes (Diabetes.org figures).By the end of this year, 4 million deaths will happen worldwide as a result of diabetes and its complications. These complications include renal failure, blindness, and amputation. It is well established clinically that good glycaemic control minimises the risk of long-term complications and improves morbidity and mortality. Current problems with frequent blood glucose testing are mainly due to patient intolerability. Many patients find finger prick testing for blood glucose levels to be painful, dislike using sharp objects and seeing their own blood. There is also a risk of infection, and in the long term, this practice can result in damage to the finger tissue. This is because the fingers have a high concentration of sensory nerve endings. Additionally, the current invasive blood glucose monitoring systems suffer limitations in terms of the requirement for continuous calibration and susceptibility to contamination by the growth of various living organisms. The Afon technology device would be a gamechanger in terms of improving the quality of life of millions of patients and improve their chances to manage the condition without severe complications.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date August 30, 2022
Est. primary completion date August 30, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years to 64 Years
Eligibility Inclusion Criteria: Patient who has a documented Type 1 diagnosis (diagnosed under age 29), or Type 2 diabetes for more than one year (with negative GAD antibody test results) and who are willing and able to give informed consent for participation in the study Male or female patient Patient aged 18 to 80 years Patients with a BMI 18-35 kg/m2. Exclusion Criteria: The patient may not enter the study if ANY of the following apply: Type 1 patients diagnosed after age 29 Type 2 patients with positive GAD antibody test results Patient with other active implantable medical devices, such as pacemakers Patient who is currently participating in another clinical trial for a pharmaceutical product Patient with a history of allergy to any materials used in the prototype sensors or materials used to stabilise the devices or cabling including Rocktape, double-sided tape and prosthetic adhesive Female patient who is pregnant or lactating - Patient with any injury or infection of the wrist - Patient who is unwilling or unable to attend each visit fasting from midnight (water is permitted freely) or fasting for a minimum of 3 hours (for an afternoon session) - Patient who takes paracetamol or aspirin in the 24 hours preceding each visit - Patient with clinically significant abnormal values in clinical chemistry, as judged by the PI - Concurrent illness or a condition that may interfere with blood glucose levels (e. g. carcinoma, haematological disease, vasculitis, connective tissue disease, alcohol neuropathy) - Patient who is incapable of giving informed legal consent - Recent (1 month) episode of DKA, HONK or severe hypoglycaemia - Patient on pramlintide (Symlin/Tripro-Amylin) - Patient who attends the visit under the influence of alcohol or recreational drugs - Patient with severe macrovascular disease - stroke, CVD, CKD stage IV -V Patient who fails screening for alcohol and recreational drugs use.

Study Design


Intervention

Device:
ATD (device test)
Medical device test (no intervention)

Locations

Country Name City State
United Kingdom JCRF Swansea

Sponsors (1)

Lead Sponsor Collaborator
Afon Technology

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Exploratory Efficacy Objective 1 To estimate real-time serial blood glucose levels from the device measurements using a gold standard methodology for blood glucose measurement as control.
A comparison addressing the potential differences of MARDs and PARDs respectively will be done for the Afon system tested and assessed using mixed effect linear models with the BG as the fixed effect and subjects as random effects. Within the model the least square means, the differences between least square means of MARD of the Afon system and corresponding two-sided 95% parametric confidence interval will be calculated.
Up to 4 hours per test session.
Primary Exploratory Efficacy Objective 2 To chart patient-specific predicted vs actual blood glucose levels over time, including before and after glucose challenge.
The type I error is set at 5% two-sided.
Up to 4 hours per test session.
Primary Safety Objective 1 To examine the safety and tolerability of the prototype sensors.
Number of participants with no device-related SAE = 0.
Up to 4 hours per test session.
Primary Exploratory Usability Objective To obtain patient input for wearable device design by means of a usability questionnaire1 answered questionnaire per participant. 25 minutes - 1 hour during a test session.
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05666479 - CGM Monitoring in T2DM Patients Undergoing Orthopaedic Replacement Surgery
Completed NCT05647083 - The Effect of Massage on Diabetic Parameters N/A
Active, not recruiting NCT05661799 - Persistence of Physical Activity in People With Type 2 Diabetes Over Time. N/A
Completed NCT03686722 - Effect of Co-administration of Metformin and Daclatasvir on the Pharmacokinetis and Pharmacodynamics of Metformin Phase 1
Completed NCT02836704 - Comparison of Standard vs Higher Starting Dose of Insulin Glargine in Chinese Patients With Type 2 Diabetes (Glargine Starting Dose) Phase 4
Completed NCT01819129 - Efficacy and Safety of FIAsp Compared to Insulin Aspart in Combination With Insulin Glargine and Metformin in Adults With Type 2 Diabetes Phase 3
Completed NCT04562714 - Impact of Flash Glucose Monitoring in People With Type 2 Diabetes Using Non-Insulin Antihyperglycemic Therapy N/A
Completed NCT02009488 - Treatment Differences Between Canagliflozin and Placebo in Insulin Secretion in Subjects With Type 2 Diabetes Mellitus (T2DM) Phase 1
Completed NCT05896319 - Hyaluronic Acid Treatment of the Post-extraction Tooth Socket Healing in Subjects With Diabetes Mellitus Type 2 N/A
Recruiting NCT05598203 - Effect of Nutrition Education Groups in the Treatment of Patients With Type 2 Diabetes N/A
Completed NCT05046873 - A Research Study Looking Into Blood Levels of Semaglutide and NNC0480-0389 When Given in the Same Injection or in Two Separate Injections in Healthy People Phase 1
Completed NCT04030091 - Pulsatile Insulin Infusion Therapy in Patients With Type 1 and Type 2 Diabetes Mellitus Phase 4
Terminated NCT04090242 - Impact of App Based Diabetes Training Program in Conjunction With the BD Nano Pen Needle in People With T2 Diabetes N/A
Completed NCT03604224 - A Study to Observe Clinical Effectiveness of Canagliflozin 300 mg Containing Treatment Regimens in Indian Type 2 Diabetes Participants With BMI>25 kg/m^2, in Real World Clinical Setting
Completed NCT03620357 - Continuous Glucose Monitoring & Management In Type 2 Diabetes (T2D) N/A
Completed NCT01696266 - An International Survey on Hypoglycaemia Among Insulin-treated Patients With Diabetes
Completed NCT03620890 - Detemir Versus NPH for Type 2 Diabetes Mellitus in Pregnancy Phase 4
Withdrawn NCT05473286 - A Research Study Looking at How Oral Semaglutide Works in People With Type 2 Diabetes in Germany, as Part of Local Clinical Practice
Not yet recruiting NCT05029804 - Effect of Walking Exercise Training on Adherence to Disease Management and Metabolic Control in Diabetes N/A
Completed NCT04531631 - Effects of Dorzagliatin on 1st Phase Insulin and Beta-cell Glucose Sensitivity in T2D and Monogenic Diabetes Phase 2