Clinical Trial Summary

Continuous Glucose Monitoring (CGM) systems improve glycaemic control in type 1 diabetic patients but they have different characteristics that could influence patients' quality of life and glycaemic control.

In this randomized cross over study investigators will compare 2 different CGM systems: Eversense implantable sensor (Senseonics, Germantown, MD, USA) and the standard transcutaneous sensor Dexcom G5 (Dexcom, San Diego, CA, USA). Investigators will evaluate sensors' accuracy, impact on quality of life and efficacy in optimizing glycaemic control.

The investigator's study's results might help clinicians choose the sensor and evaluate how sensor differences could impact glycaemic control.


Description:

Good glycaemic control in type 1 diabetic patients prevents the onset and progression of chronic complications. Continuous Glucose Monitoring (CGM) systems help patients improve glycaemic control by providing real-time glucose levels, glycaemic tendency, glycaemic swing rate and by alerting the patient when the glucose value read by the sensor reaches a predefined threshold of hyper or hypoglycaemia.

Several CGM systems are available and they have different characteristics that could influence patients' quality of life and glycaemic control.

In this randomized cross over study investigators will compare 2 different CGM systems: Eversense implantable sensor (Senseonics, Germantown, MD, USA) and the standard transcutaneous sensor Dexcom G5 (Dexcom, San Diego, CA, USA). Investigators will evaluate sensors' accuracy, impact on quality of life and efficacy in optimizing glycaemic control.

Patients will use Dexcom G5 or Eversense for three months, respectively, in a randomized order. Accuracy will be evaluated comparing sensors values with capillary blood glucose at home.

Quality of life will be assessed at the beginning and at the end of each three-month period through validated questionnaires to underline differences in different sensors use.

Time spent in target (70-180 mg/dl), in hypoglycamiea and hyperglycemia will be evaluated with both sensors to assess differences in glycaemic control induced by different alarm system and by the presence of predictive alarms


Recruitment information / eligibility

Status Completed
Enrollment 16
Est. completion date September 1, 2019
Est. primary completion date December 31, 2018
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Male and female participants of at least 18 years of age

- Diagnosis of type 1 diabetes mellitus (diagnosed according to World Health Organization criteria) for at least 1 year

- Body Mass Index (BMI) <35 kg / m²

- Availability to wear study equipment and to comply with the study protocol for its entire duration

- HbA1c <10%

- Signature of informed consent before any procedure related to the study.

Exclusion Criteria:

- Pregnancy, breastfeeding, intention to undergo pregnancy or refusal to use contraceptive methods during the study period (for female subjects).

- Known allergies to skin patches or disinfectants used during the study.

- Skin lesions, irritation, redness, edema in sites where sensors can be applied, as this might interfere with sensor's placement or with the accuracy of the glycaemic value detection.

- Use of drugs that may interfere with glucose metabolism (such as steroids) unless they are chronic therapies whose dosage has remained stable over the past 3 months and is expected to remain stable during the study period.

- Use of acetaminophen or other drugs that could influence sensor accuracy

- Severe medical or psychological conditions, which, in the opinion of the medical team, may compromise patients' safety while participating in the study.

- Patients enrolled in other clinical trials.

- Known disorders of adrenal glands, pancreatic tumors or insulinoma

- Patient's inability to comply with the procedures of the study

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Dexcom G5-Eversense
Patients will wear sensor for 3 months, monitor blood capillary values 4 times/day. At the beginning and at the end of the period HbA1c will be measured and questionnaires will be administered
Eversense-Dexcom G5
Patients will wear sensor for 3 months, monitor blood capillary values 4 times/day. At the beginning and at the end of the period HbA1c will be measured and questionnaires will be administered. After 30-50 days of sensor implantation patients will wear also Dexcom G5 for a week to compare accuracy simultaneously

Locations

Country Name City State
Italy University of Padova Padova

Sponsors (1)

Lead Sponsor Collaborator
University of Padova

Country where clinical trial is conducted

Italy, 

Outcome

Type Measure Description Time frame Safety issue
Primary device accuracy sensors' accuracy expressed in terms of MARD (mean absolute relative difference) versus capillary blood glucose in different glycaemic ranges after 3 months, at the end of the study for each arm of the study
Secondary Time spent in target % Time spent in target (70-180 mg/dl) using each sensor to evaluate sensor efficacy after 3 months, at the end of the study for each arm of the study
Secondary HbA1c HbA1c changes using different sensors, to evaluate sensor efficacy after 3 months, at the end of the study for each arm of the study
Secondary failure % Sensors' failure rate to evaluate sensor duration after 3 months, at the end of the study for each arm of the study
Secondary Adverse events Adverse events (skin reactions, haematomas) after 3 months, at the end of the study for each arm of the study
Secondary changes in quality of life DTSQ questionnaire after 3 months, at the end of the study for each arm of the study
Secondary changes in fear of hypoglycaemia HFSII questionnaire after 3 months, at the end of the study for each arm of the study
See also
  Status Clinical Trial Phase
Completed NCT04030091 - Pulsatile Insulin Infusion Therapy in Patients With Type 1 and Type 2 Diabetes Mellitus Phase 4
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT01696266 - An International Survey on Hypoglycaemia Among Insulin-treated Patients With Diabetes
Recruiting NCT06050642 - Study of the Impact of PROximity Support for Patients With Type 1 DIABetes Treated With an Insulin Pump or Closed Loop. N/A
Completed NCT05107544 - Metabolic, Physical Fitness and Mental Health Effects of High Intensity Interval Training (HIIT) in Adolescents With Type 1 Diabetes N/A
Active, not recruiting NCT04443153 - Adapting Diabetes Treatment Expert Systems to Patient in Type 1 Diabetes N/A
Completed NCT04521634 - Glycaemic Variability in Acute Stroke
Completed NCT04569994 - A Study to Look at the Safety of NNC0363-0845 in Healthy People and People With Type 1 Diabetes Phase 1
Completed NCT04089462 - Effects of Frequency and Duration of Exercise in People With Type 1 Diabetes A Randomized Crossover Study N/A
Completed NCT03143816 - Study Comparing Prandial Insulin Aspart vs. Technosphere Insulin in Patients With Type 1 Diabetes on Multiple Daily Injections: Investigator-Initiated A Real-life Pilot Study-STAT Study Phase 4
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A
Completed NCT04042207 - Diabeloop for Highly Unstable Type 1 Diabetes N/A
Not yet recruiting NCT06068205 - COMPARATIVE ANALYSIS OF THE MORPHO-MECHANICAL PROPERTIES OF RED BLOOD CELLS EXTRACTED FROM DIABETIC PATIENTS WITH AND WITHOUT MICROVASCULAR COMPLICATIONS
Recruiting NCT05909800 - Prolonged Remission Induced by Phenofibrate in Children Newly Diagnosed With Type 1 Diabetes. Phase 2
Active, not recruiting NCT04974528 - Afrezza® INHALE-1 Study in Pediatrics Phase 3
Completed NCT04530292 - Home Intervention and Social Precariousness in Childhood Diabetes N/A
Completed NCT05428943 - OPT101 in Type 1 Diabetes Patients Phase 1
Recruiting NCT03988764 - Monogenic Diabetes Misdiagnosed as Type 1
Completed NCT05597605 - The SHINE Study: Safety of Implant and Preliminary Performance of the SHINE SYSTEM in Diabetic Subjects N/A