Verified date June 2009
Source Mellitor
Contact Hanna Levy, Dr.
Phone (972)-4-638-8837
Email hanna@qsitemed.com
Is FDA regulated No
Health authority Israel: Ethics Commission
Study type Interventional

Clinical Trial Summary

Most patients with diabetes mellitus have to measure their blood glucose levels quite often, in order to maintain a proper glycemic control. Current methods of self-monitoring of blood glucose are invasive, painful, uncomfortable, and only allow occasional, from time-to-time, measurements. Real-time continuous monitoring would provide a helpful tool for improvement of glycemic control, thus decreasing the incidence of hypoglycemia and improving glucose control. The Mellitor sensor is a new concept of continue glucose monitoring device. The Mellitor device is an implantable continuous glucose monitoring sensor that is intended for detection episodes of hyperglycemia and hypoglycemia in diabetic patients, and facilitates both acute and long-term therapy adjustments. This study was design in order to evaluate glucose measurement capabilities by the Mellitor sensor that is being developed. Transudate liquid samples, withdrawn in a clinical procedure and normally immediately disposed, will be used for glucose measurement by the Mellitor sensor.

Study Design

This study is an ex-vivo comparative study. 20 patients will be recruited for the study, according to patients' inflow and meeting eligibility criteria.

Study Goal

Study objective is to evaluate the feasibility of the Mellitor Sensor technology for glucose level measurement.

Study Endpoint

Mellitor technology feasibility will be established by comparing Mellitor glucose measurements results, based on transudate/exudates liquid withdrawal for other medical reasons, to "gold standard, Yellow Springs" glucose analyzer, or a comparable, calibrated and approved device using the same transudate/exudates liquid. Interdevice variability should be within 10%.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 20
Est. completion date October 2010
Est. primary completion date May 2010
Accepts healthy volunteers No
Gender Both
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Male/Female aged 18 and up.

- Subject was scheduled for transudate/exudate liquid withdrawal.

- Subject able to comprehend and give informed consent for participation in this study.

- Signed Informed Consent Form

Exclusion Criteria:

- Known cognitive or psychiatric disorder.

- Subjects with HIV.

- Subject refuses to sign inform consent form.

Study Design

Allocation: Non-Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


Intervention

Device:
Mellitor device for glucose measurement
Glucose measurement using "Mellitor" device

Locations

Country Name City State
Israel Hadassah Medical Organization Jerusalem

Sponsors (1)

Lead Sponsor Collaborator
Mellitor

Country where clinical trial is conducted

Israel, 

Outcome

Type Measure Description Time frame Safety issue
Primary Mellitor technology feasibility will be established by comparing Mellitor glucose measurements results to "gold standard, Yellow Springs" glucose analyzer, or a comparable. Interdevice variability should be within 10%. during glucose measurements No
See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A