Diabetes Mellitus Clinical Trial
Official title:
VerioVue Enhancements Regulatory Clinical Evaluation - Professional Comparison to Validated Method: Arterial Study
The aim of this performance evaluation is to compare the blood glucose results obtained using the VerioVue Blood Glucose Monitoring System (BGMS) with those obtained from a validated comparator method (iSTAT 1 Analyser) using arterial blood. The main question the study aims to answer is: How accurate is the VerioVue BGMS when compared to a product that has already been confirmed as accurate (iSTAT 1 Analyser) when hospital staff test arterial blood on these two types of instrument? Participants will have a small amount of blood taken from an existing arterial line.
Up to two UK NHS hospital sites will be used to collect a minimum of 100 evaluable samples from participants fitted with an arterial line that meet the acceptance criteria. Consent will be obtained from the participants prior to taking part in the study. If the participant meets the enrolment criteria then demographics and medical history information will be collected. A small volume of blood (max 150µl) will be collected from an existing arterial line. The blood will then be applied to six investigational OneTouch VerioVue meters (with expanded haematocrit range 20-65%) fitted with OneTouch Verio test strips and the blood glucose meter readings recorded. Three different lots of test strips will be used in rotation across the study. Within 5 minutes of the last meter test, trained staff will use blood from the same sample and perform a test on the iSTAT Analyser to obtain the blood glucose, haematocrit and oxygen levels of the sample. No treatment decisions will be made based on the blood glucose results obtained for this study. The study documentation will be reviewed by LifeScan monitors for completeness and accuracy and the results entered into a validated database. The data will be extracted and statistically analysed to determine the accuracy of the arterial blood glucose results obtained using the OneTouch VerioVue BGMS when compared to the arterial blood glucose results obtained on the iSTAT 1 Analyser. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03743779 -
Mastering Diabetes Pilot Study
|
||
Completed |
NCT03786978 -
Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus
|
N/A | |
Completed |
NCT01804803 -
DIgital Assisted MONitoring for DiabeteS - I
|
N/A | |
Completed |
NCT05039970 -
A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program
|
N/A | |
Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
Completed |
NCT04068272 -
Safety of Bosentan in Type II Diabetic Patients
|
Phase 1 | |
Completed |
NCT03243383 -
Readmission Prevention Pilot Trial in Diabetes Patients
|
N/A | |
Completed |
NCT03730480 -
User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS)
|
N/A | |
Recruiting |
NCT02690467 -
Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm.
|
N/A | |
Completed |
NCT02229383 -
Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus
|
Phase 3 | |
Completed |
NCT05799976 -
Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure
|
N/A | |
Completed |
NCT06181721 -
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
|
N/A | |
Recruiting |
NCT04489043 -
Exercise, Prediabetes and Diabetes After Renal Transplantation.
|
N/A | |
Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
Completed |
NCT03542084 -
Endocrinology Auto-Triggered e-Consults
|
N/A | |
Completed |
NCT02229396 -
Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo
|
Phase 3 | |
Recruiting |
NCT05544266 -
Rare and Atypical Diabetes Network
|
||
Completed |
NCT01892319 -
An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
|
||
Completed |
NCT05031000 -
Blood Glucose Monitoring Systems: Discounter Versus Brand
|
N/A | |
Recruiting |
NCT04039763 -
RT-CGM in Young Adults at Risk of DKA
|
N/A |