Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to determine if restoring normal metabolic function in patients with type 1 or type 2 diabetes can improve the impact of the consequences of diabetic complications on the overall health and quality of life for diabetic patients.Patients are treated once per week with intensive bolus intravenous insulin delivery mimicking normal insulin secretions in a non diabetic individual. Baseline and periodic diagnostic tests are performed and questionnaires completed to evaluate and monitor progress and outcomes.


Clinical Trial Description

It is known that the glucose metabolic pathway is the primary fuel generator to the brain, nerve tissue, heart, vascular tissue, eyes, kidneys and the liver. Deficient metabolism state as seen in the glucose metabolism experienced in many diabetic patients can lead to complications. These damaging effects are exacerbated by altered cellular metabolites, specifically the increase in catabolic and decrease in anabolic factors. It has been shown over the past 20 years that normalization of metabolism in diabetic patients can be accomplished by mimicking the normal endogenous insulin pattern from the pancreas. Intensive intravenous insulin bolus has been demonstrated to reverse the metabolic state from primary fat utilization to carbohydrate utilization through monitoring of the subject's respiratory quotient.

This study measures whether the reversal of abnormal metabolism in patients with diabetes is correlated with an improvement in their quality of life and associated complication related to their diabetes. The respiratory quotient (RQ) is a measurement of CO2 exhaled and O2 inhaled and is proportionate to the fuel sources being used by the body, primarily the liver over short periods of time. The higher the RQ, the more glucose and less alternative fuel sources are being utilized. Following the RQ change helps determine the effectiveness of physiological intravenous bolus insulin administration in increasing anabolic functions in diabetic individuals. By improving the body's glucose metabolism and thereby causing beneficial effects of anabolic factors, the possibility of serious complications may be decreased. In addition, the use of oral carbohydrate at the same time along with the physiologic intravenous bolus insulin administration stimulates the appropriate gut hormones which augment this effect, a response which cannot be duplicated with intravenous glucose. The purpose of our study is to determine whether the physiologic administration of intravenous bolus insulin along with the augmenting effect of oral carbohydrates will normalize metabolism in diabetic patients and improve their metabolic integrity and quality of life indices.

The RQ is determined by the use of a metabolic cart. Individuals breathe into a mask for 3-5 minutes after a rest period of 20 or more minutes. The ratio of exhaled volume of CO2 to the inhaled volume of O2 is determined as the RQ. The physiologic range is 0.7 to1.3. Individuals using fat as a primary fuel have a ratio of 0.7, protein or mixed fuels is 0.8-0.9 and carbohydrate is 0.9-1.0. Those taking excessive calories will have RQ's higher than 1.05. The RQ can be followed serially to monitor progress aand outcomes and this is done before and after each sixty minute intravenous bolus insulin treatment session, during the 3 successive sessions on a single treatment day. The amount of intravenous insulin and oral glucose given is determined by monitoring the RQ changes during the previous session.Intravenous bolus insulin therapy encourages the glucose metabolism in diabetics to normalize metabolic integrity in multiple organs, especially muscle, retina, liver, kidney and nerve endings. The process fundamentally requires the administration of high dose intravenous insulin boluses similar to those found in non diabetic humans by their pancreas into the surrounding portal circulation. Oral carbohydrates are given simultaneously to augment the process and prevent hypoglycemia. The process is monitored by frequent glucose levels and respiratory quotients (RQ). RQ is measured by a metabolic cart which determines the ratio VCO2/ VO2. This ratio is specific for the fuel used at any one time by the body. The glucose levels are monitored every thirty minutes or more frequently as medically necessary to keep glucose levels appropriate and the RQ determines the need to readjust the infusion protocol in each patient for subsequent intravenous bolus insulin infusion sessions.Patient is evaluated post session and discharged when stable.

Frequent monitoring of RQ and glucose is necessary as these levels change rapidly, depending on the fuel being utilized by the body. Intravenous bolus insulin therapy shifts metabolism from primarily fatty acid metabolism to primarily glucose metabolism. This shift is reflected by the increase in respiratory quotient. However during rest periods the RQ may fall back to lower levels. Therefore RQ's are done at the beginning and at the end of each insulin infusion session of 1 hour in order to appropriately monitor and adjust insulin and carbohydrate loads to reach optimal activation in each session. ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01023165
Study type Interventional
Source Global Infusion and Aspiration Systems, LLC
Contact Michael Cockrell, MD
Phone 662-267-2025
Email lg@global-infusions.com
Status Recruiting
Phase Phase 3
Start date November 2009
Completion date November 2015

See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A