Clinical Trials Logo

Clinical Trial Summary

This study compares two intubation boxes, that is the Taiwan "Aerosol Box" versus the UMMC "Intubation Box". The importance of this intubation box has come to light recently in view of the COVID-19 pandemic and the fact that intubation is an aerosol-generating procedure. Risks of the healthcare worker attending to the airway of COVID-19 patients is high and the intubation box aims to minimize that and reduce contamination of the environment. The original design of the "Aerosol Box" has limitations and is not easily used by intubators. This study evaluates the clinical usefulness of an innovation of the "Aerosol Box" design that is made to be more ergonomic and increases the rate of successful intubation. Anaesthetists with more than 5 years of clinical experience in intubating airways as well as more than 20 successful intubations using videolaryngoscopy , will be available to participate. This study will employ manikin and will be a randomized cross-over trial, conducted in UM.


Clinical Trial Description

Background:

Intubation is classified as an aerosol-generating procedure (AGP). Intubation in a confirmed COVID-19 patient with a high viral load poses a high risk of exposure to health care workers (HCW). To reduce this risk, the HCW and their assistants are advised to don full personnel protective equipment (PPE) with a powered air purifying respiratory (PAPR) during intubation. In view of this concern, this procedure is highly recommended to be done in a negative pressure room to control the spread of aerosolizing particles in the room. A first-pass success in intubation is also crucial to minimize the risk of infection to health care workers involved.

Introduction :

An Aerosol Box (from here on known as Box A) was recently designed by Dr. Lai Hsien Yung from Taiwan which adds extra protection to the intubator and the surrounding environment. The Aerosol Box is a transparent box made of acrylic or transparent polycarbonate sheet, designed with an opening on one side allowing it to fit over the patient's chest and neck, while the opposing side has two holes through which the intubator can insert their hands through. It was shown that this barrier enclosure during intubation protects the laryngoscopist. A recent study simulated a patient with a cough during intubation with and without the Aerosol Box. With the box, it was demonstrated that the simulated cough resulted in contamination of only the inner surface of the box, the laryngoscopist's gloves and gowned forearms. Examination of the laryngoscopist and the room with ultraviolet light after the simulated cough also showed no macroscopic contamination outside the box. In contrast, intubation without the box demonstrated that the laryngoscopist's gown, gloves, face mask, eye shield, hair, neck, ears, and shoes were all contaminated.

Feedbacks from our colleagues stated that intubation with Box A is slightly difficult and may cause delay in intubation. Canelli et al also concluded this observation. The investigators, therefore, innovated the design of Box A to facilitate the laryngoscopist, known as the UMMC Intubation Box (from here on known as Box B). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04385576
Study type Interventional
Source University of Malaya
Contact SHAIRIL R RUSLAN, MAnaes(UM)
Phone +60123291074
Email shairil@ummc.edu.my
Status Recruiting
Phase N/A
Start date May 15, 2020
Completion date December 30, 2020

See also
  Status Clinical Trial Phase
Withdrawn NCT06065033 - Exercise Interventions in Post-acute Sequelae of Covid-19 N/A
Completed NCT06267534 - Mindfulness-based Mobile Applications Program N/A
Completed NCT05047601 - A Study of a Potential Oral Treatment to Prevent COVID-19 in Adults Who Are Exposed to Household Member(s) With a Confirmed Symptomatic COVID-19 Infection Phase 2/Phase 3
Recruiting NCT05323760 - Functional Capacity in Patients Post Mild COVID-19 N/A
Recruiting NCT04481633 - Efficacy of Pre-exposure Treatment With Hydroxy-Chloroquine on the Risk and Severity of COVID-19 Infection N/A
Completed NCT04537949 - A Trial Investigating the Safety and Effects of One BNT162 Vaccine Against COVID-19 in Healthy Adults Phase 1/Phase 2
Completed NCT04612972 - Efficacy, Safety and Immunogenicity of Inactivated SARS-CoV-2 Vaccines (Vero Cell) to Prevent COVID-19 in Healthy Adult Population In Peru Healthy Adult Population In Peru Phase 3
Recruiting NCT05494424 - Cognitive Rehabilitation in Post-COVID-19 Condition N/A
Active, not recruiting NCT06039449 - A Study to Investigate the Prevention of COVID-19 withVYD222 in Adults With Immune Compromise and in Participants Aged 12 Years or Older Who Are at Risk of Exposure to SARS-CoV-2 Phase 3
Enrolling by invitation NCT05589376 - You and Me Healthy
Completed NCT05158816 - Extracorporal Membrane Oxygenation for Critically Ill Patients With COVID-19
Recruiting NCT04341506 - Non-contact ECG Sensor System for COVID19
Completed NCT04384445 - Zofin (Organicell Flow) for Patients With COVID-19 Phase 1/Phase 2
Completed NCT04512079 - FREEDOM COVID-19 Anticoagulation Strategy Phase 4
Active, not recruiting NCT05975060 - A Study to Evaluate the Safety and Immunogenicity of an (Omicron Subvariant) COVID-19 Vaccine Booster Dose in Previously Vaccinated Participants and Unvaccinated Participants. Phase 2/Phase 3
Active, not recruiting NCT05542862 - Booster Study of SpikoGen COVID-19 Vaccine Phase 3
Withdrawn NCT05621967 - Phonation Therapy to Improve Symptoms and Lung Physiology in Patients Referred for Pulmonary Rehabilitation N/A
Terminated NCT05487040 - A Study to Measure the Amount of Study Medicine in Blood in Adult Participants With COVID-19 and Severe Kidney Disease Phase 1
Terminated NCT04498273 - COVID-19 Positive Outpatient Thrombosis Prevention in Adults Aged 40-80 Phase 3
Active, not recruiting NCT06033560 - The Effect of Non-invasive Respiratory Support on Outcome and Its Risks in Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2)-Related Hypoxemic Respiratory Failure