Coronary Artery Disease Clinical Trial
Official title:
A Cross-Sectional Study and a Novel Screening Survey for Radial Artery Assessment in Surgical Coronary Revascularisation
The goal of this observational study is to learn about how screening tests inform the radial artery (RA) suitability for harvesting and coronary bypass grafting in adults with ischaemic heart disease. The main question it aims to answer is: • What factors influence the diagnostic accuracy of RA screening in patients undergoing surgical coronary revascularisation? Participants will: - Receive an assessment of their RA through routinely used techniques (Modified Allen Test +/- pulse-oximetry, Barbeau Test and Ultrasound examination) - Answer a symptoms scale about their physical experience after surgery
A multi-centre cross-sectional study design to investigate the validity of radial artery (RA) assessment techniques in adults with ischaemic heart disease undergoing surgical coronary revascularisation with their RA being selected as an autologous graft conduit. Patients taking part in the study will receive an assessment of the arterial forearm circulation from their non-dominant upper extremity through multiple observations. Pre-operative observations. Before surgery (in the ward environment after the patient is being admitted or whilst patient in the anaesthetic room) the forearm blood circulation is measured through a Modified Allen Test (MAT) (+/- pulse-oximetry), Barbeau Test and Ultrasonography examination. Assessment will be performed by experienced Surgical Care Practitioners/Advanced Nurse Practitioners/Cardiac Specialist Registrars. These assessments will inform the decision to surgically expose the RA. Intra-operative observations. Oxygen saturation readings are taken prior to harvest the RA. Once the RA is surgically harvested a series of measures are taken through a validated structured questionnaire: the Radial Artery Quality Evaluation Survey (RAQES). Observations at 4-6 weeks post operation. Patients finger movements, cold tolerance sensitivity and tactile/touch perception is measured through an ordinal symptoms scale (Follow-up Radial Artery Harvesting Scale) at post-operative day 2-5 and at follow-up appointment (3-6 weeks after surgery). Bilateral comparison between hands and forearms will be undertaken. A Surgical Care Practitioner will perform this assessment post-operatively. Consecutive sampling will be used for the recruitment of study participants. The minimum required number of participants to test and verify research hypotheses is sixty-nine patients (N=69). An adaptive trial design will be implemented: at quarterly assessment points the statistical power is assessed and the remaining sample size required is updated accordingly. Sample size calculation was undertaken using G*Power software (version 3.1) using Chi-squared Test and adopting optimal effect size (w=0.4) and power (0.8). Descriptive and inferential statistics will be used to perform quantitative analyses. Descriptive statistics (mode, median) will be implemented to analyse RAQES answers and ordinal symptoms scale findings and cross-tabulation used to record relationship between variables. Data analysis will also include measurement of sensitivity, specificity, positive and negative predictive values to investigate the validity of the RA assessment techniques. Correlational analysis will be implemented and Receiver Operating Characteristic curve analysis will be used to compare the diagnostic accuracy of the MAT, pulse-oximetry guided MAT and Barbeau Test with the ultrasonography examination. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |